Plan Review Details - Permit 15030326
Plan Review Stops For Permit 15030326
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-25 Cont ID  
Sent By jwitmer Date 2015-04-25 Time 10:32 Rev Time 0.00
Received By jwitmer Date 2015-04-25 Time 10:00 Sent To  
Notes
2015-04-25 10:34:16BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15030326
 ADD: 5335 N. MILITARY TRL. SUITE # 33
 CONT: MIKE MOORE CONSTRUCTION
 TEL: (561)301-9468
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 BUILDING PROVISO:
 AT RATED WALLS PLEASE HAVE THE FIRE STOPPING
 MANUFACTURER SPEC SHEET IN COMPLIANCE WITH:
 2010FBC-B 713.3.1.2 THROUGH-PENETRATION FIRESTOP
 SYSTEM. THROUGH PENETRATIONS SHALL BE
 PROTECTED BY AN APPROVED PENETRATION FIRESTOP SYSTEM
 INSTALLED AS TESTED IN ACCORDANCE
 WITH ASTM E 814 OR UL 1479, WITH A MINIMUM POSITIVE
 PRESSURE DIFFERENTIAL OF 0.01 INCH OF
 WATER AND SHALL HAVE AN F RATING OF NOT LESS THAN THE
 REQUIRED FIRE-RESISTANCE RATING OF THE
  
 WALL PENETRATED.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-16 Cont ID  
Sent By jwitmer Date 2015-03-16 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2015-03-16 Time 09:21 Sent To  
Notes
2015-03-16 09:43:17BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15030326
 ADD: 5335 N. MILITARY TRL.
 CONT: MIKE MOORE CONSTRUCTION
 TEL: (561)301-9468
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 1ST REVIEW
 DATE: MON. MARCH 16/ 2015
 ACTION: DENIED
  
 1) BETWEEN THE DEMO SHEET AND SHEET A-1 IT APPEARS THAT
 THIS PERMIT IS TO PUT THE 3 UNITS TO BE A VANILLA BOX
 W/ NO RESTROOMS NOR PLUMBING.
 ON THE DEMO SHEET THE PLANS INDICATE TO CAP OFF
 PLUMBING. THE PLANS DO NOT MAKE IT CLEAR IF THE
 PLUMBING THAT PENETRATES THE TENANT SEPERATION WALL, IF
 IT IS TO BE CAPPED OFF BEHIND THE WALL OR IF CAPPED OFF
 IN THE TENANT SPACE. SHEET A-1 SHOWS PENETRATIONS OF
 FIRE RATED WALLS, THESE DETAILS REFERANCE DETAIL 5
 SHEET A-6. NO SHEET IS FOUND IN THIS SET OF DRAWINGS.
 THE OTHER ISSUE IS WALL PENETRATION SCHEDULE LIST
 VARIOUS U.L. LISTINGS. PLEASE PRINT THESE LISTINGS
 SINCE THE FIELD INSPECTOR WILL NEED THEM FOR
 VARIFICATION.
  
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND TO THE TECHNICAL
 CODES.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-05-14 Cont ID  
Sent By rlecky Date 2015-05-14 Time 11:49 Rev Time 0.00
Received By rlecky Date 2015-05-14 Time 11:49 Sent To  
Notes
2015-04-15 09:27:06NEW DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-23 Cont ID  
Sent By dhayes Date 2015-03-23 Time 12:53 Rev Time 0.00
Received By dhayes Date 2015-03-23 Time 12:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-04-15 Cont ID  
Sent By pleduc Date 2015-04-15 Time   Rev Time 0.00
Received By pleduc Date 2015-04-15 Time 16:31 Sent To  
Notes
2015-04-15 16:39:15THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
2015-04-15 09:27:24NEW DRAWINGS SUBMITTED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-03-12 Cont ID  
Sent By pleduc Date 2015-03-12 Time   Rev Time 0.00
Received By pleduc Date 2015-03-12 Time 12:21 Sent To  
Notes
2015-03-12 13:48:20THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-14 Cont ID  
Sent By tklarge Date 2015-05-14 Time 14:54 Rev Time 0.00
Received By tklarge Date 2015-04-14 Time 09:27 Sent To  
Notes
2015-04-15 09:28:10RE-SUBMITTAL SENT TO B28 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-14 Cont ID  
Sent By skennedy Date 2015-04-14 Time 11:51 Rev Time  
Received By skennedy Date 2015-03-09 Time   Sent To  
Notes
2015-03-09 17:20:32SENT TO B28.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-03-09 Cont ID  
Sent By jwitmer Date 2015-03-09 Time 17:20 Rev Time 0.00
Received By jwitmer Date 2015-03-09 Time 17:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-05-13 Cont ID  
Sent By skennedy Date 2015-05-18 Time 15:12 Rev Time 0.00
Received By ccole Date 2015-05-18 Time 12:25 Sent To  
Notes
2015-05-18 12:27:295/18/2015 PASSED.
 MECH. PROVISIO: REMOVE BATH EXHAUST FNS AND EXHAUST
 DUCTS. CAP AND SEAL EXTERIOR OPENINGS.
  
 CHRISTOPHER COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
2015-05-13 15:16:27REVIEW BY CHRIS COLE
  
 1) SHEET D-1: PROVIDE A SCOPE OF WORK FOR MECHANICAL
 DEMOLITION ON THE PLAN.
 2) PROVIDE VENTILATION AND AC LOAD CALCULATIONS FOR THE
 PROPOSED NEW TENANT SPACES: TABLE 403.3 FMC-2010 &
 SECTION 503.2.1 FBC-10 ENERGY,
 OR PLACE A NOTE INDICATING TO BE DONE UNDER SEPARATE
 PERMIT.
  
 CHRISTOPHER COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-04-14 Cont ID  
Sent By skennedy Date 2015-04-14 Time 11:51 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
2015-04-14 11:52:57FAILED W/O REVIEW TO ALLOW FOR RESUBMITTAL.

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-05-14 Cont ID  
Sent By tklarge Date 2015-05-14 Time 14:54 Rev Time 0.00
Received By tklarge Date 2015-05-14 Time 14:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-02 Cont ID  
Sent By tklarge Date 2015-04-02 Time 03:02 Rev Time 0.00
Received By tklarge Date 2015-04-01 Time 14:53 Sent To  
Notes
2015-04-01 15:17:551) COMPLY WITH BUILDING PLAN REVIEW NOTES.
 2) INDICATE THE PROPOSED OCCUPANCY FOR THESE NEWLY
 CREATED BAYS. HANDICAP ACCESSIBLE DRINKING FOUNTAINS
 MAY BE REQUIRED FOR EACH OF THESE SPACES.
 3) SHOW THE SQUARE FOOTAGE OF EACH SPACE. WPB AMEND. TO
 2010 FBC SEC.107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-05-08 Cont ID  
Sent By ajones Date 2015-05-08 Time 15:38 Rev Time 0.00
Received By ajones Date 2015-05-08 Time 13:56 Sent To  
Notes
2015-04-15 09:26:35NEW DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-03-10 Cont ID  
Sent By ajones Date 2015-03-10 Time 14:14 Rev Time 0.00
Received By ajones Date 2015-03-10 Time 14:14 Sent To  
Notes
***NONE***