Plan Review Details - Permit 15020798
Plan Review Stops For Permit 15020798 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-05-13 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-05-13 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-03-14 |
|
|
Cont ID |
|
Sent By |
misc2 |
Date |
2015-03-14 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-14 |
Time |
15:05 |
Sent To |
FIRE |
|
Notes |
2015-03-14 15:27:32 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THE APPLICATION IS FOR 3201 ELECTRONICS WAY, PLANS | | ARE FOR 109 RUSSELL DR. PLEASE CORRELATE, FBC 107. | | | | 2. SHEET A1 IS NOT CLEAR AS TO LOCATION AND SCOPE OF | | WORK PROPOSED. IT APPEARS THAT ENGINEER USED A ROOF | | PLAN PREPARED BY OTHERS AND ADDED INFORMATION. ELMINATE | | INFORMATION WHICH IS NOT APPLICABLE TO THIS JOB, CREATE | | A LEGEND AND CLEARLY SHOW LOCATION OF PROPOSED LADDERS | | AND GUARDS, FBC 107. CLOUDED INFORMATION APPEARS TO BE | | UNRELATED TO THIS JOB. | | | | 3. SPECIFY LOADS, FBC 1607.7, FBC TABLE 1607.1, FBC | | 1509.6. | | | | 4. SHOW COMPLIANCE WITH THE REQUIREMENTS OF FBC 1509.6. | | PROVIDE ADDITIONAL DETAILS AS NECESSARY. | | | | 5. PROVIDE A STRUCTURAL DETAIL FOR CONSTRUCTION OF THE | | GUARDS, LADDERS, WALKWAY, FBC 107. FOR INSTANCE, NO | | INFORMATION PROVIDED REGARDING HOW THE RAILING IS | | CONTRUCTED, ONLY THE MATERIAL SPECIFIED. CONNECTORS? | | WELDS? "EASTERN METAL SUPPLY GANGWAY DECK" SPECIFIED, | | NO INFORMATION PROVIDED FOR THIS PRODUCT, OR FOR THE | | "EASTERN METAL LADDER RUNG". DO THESE ITEMS HAVE A | | PRODUCT APPROVAL? ENGINEERING? | | | | 6. WHAT IS 3/8" W.A.B.? PROVIDE A LEGEND OR SPELL OUT | | STRUCTURAL ABBREVIATIONS (ELEVATION VIEW, OTHER PLACES, | | SHEET S1). | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-05-06 |
Time |
16:56 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-03-17 |
Time |
12:14 |
Sent To |
PC |
|
Notes |
2015-03-17 13:06:15 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | A LIFE SAFETY PLAN WAS NOT SUBMITTED AND IS REQUIRED TO | | INCLUDE, PATH OF TRAVEL, EXIT SIGNAGE, LIGHTING, ETC | | | | THE CONSTRUCTION/INSTALLATION OF THE LADDERS AND BRIDGE | | SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 101, CHAPTER | | 7, 7.2.9. | | | | THERE IS NO INDICATION OF A STEP-DOWN (OR STEP-UP) | | DIMENSION AT THE BRIDGE CONNECTING TO THE BUILDING. | | BASED ON THE HEIGHT OF THE STEPS ADDITIONAL STEPS MAY | | BE NEEDED. | | | | THE ENDS OF THE HAND RAIL ON THE BRIDGE SHALL EXTEND | | PASSED THE END OF THE WALKWAY CONSISTANT WITH THE | | REQUIREMENTS OF 7.2.2.4 FOR ANY STEP DOWN (UP) OR | | APPROACH TO THE EDGE OF THE BUILDING. | | | | THERE IS NO DIMENSION INDICATED OF THE HEIGHT OF THE | | LAST LADDER RUNG TO THE GROUND. | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-05-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-05-14 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-05-05 |
Time |
09:25 |
Sent To |
|
|
Notes |
2015-05-06 09:25:41 | RE-SUBMITTAL SENT TO FIRE SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-02-25 |
Time |
12:16 |
Sent To |
Z |
|
Notes |
2015-03-14 15:28:00 | 3/14 TO FIRE | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
misc2 |
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
|