Plan Review Stops For Permit 15020744 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-23 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-23 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-06-15 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-15 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-15 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:22 |
Rev Time |
|
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-03-20 12:22:58 | 1ST REVIEW: FBC 2010 | | | | APPLICANT HAS DECIDED TO SUBMIT NEW DESIGN DOCUMENTS. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | 2015-03-20 12:22:36 | 1ST REVIEW: FBC 2010 | | | | APPLICANT HAS DECIDED TO SUBMIT NEW DESIGN DOCUMENTS. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-24 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-24 |
Time |
13:59 |
Sent To |
|
|
Notes |
2015-06-24 14:48:44 | 6/9/2015 | | PROJECT: RESIDENTIAL RENNOVATION | | PERMIT#:15020744 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN | | APPROVED PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | 1) DISCONNECT REQUIRED FOR WATER HEATER. NEC 422.31 | | | | 2) BUILDINGS OR STRUCTURES SUPPLIED BY FEEDERS SHALL | | HAVE A GROUNDING ELECTRODE OR GROUNDING ELECTRODE | | SYSTEM INSTALLED IN ACCORDANCE WITH PART III OF ARTICLE | | 250. THE GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE | | CONNECTED IN ACCORDANCE WITH 250.32(B) OR (C). NEC | | 250.32(A) | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-09 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-09 |
Time |
10:52 |
Sent To |
B |
|
Notes |
2015-06-09 11:25:03 | 6/9/2015 | | PROJECT: RESIDENTIAL RENNOVATION | | PERMIT#:15020744 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) THE RISER DIGRAM INDICATES A # 6 FEEDER TO THE | | 100AMP SUB PANEL IN THE GUEST HOUSE. $6 CU IS NOT | | APPROVED FOR THE TOTAL CONNECTED DEMAND LOADS OF 85 | | AMPS OR THE 100AMP OCPD . | | | | 2) OUTLETS IN THE KITCHEN SHALL MEET THE PROVISIONS OF | | THE NEC 210.52(A)(2) | | | | 3) OUTLETS IN THE BALANCE OF THE DWELLING SHALL MEET | | THE PROVISIONS OF THE NEC 210.52(A)(1) | | | | 4) SMOKE DETECTORS ARE REQUIRED TO MEET THE | | REQUIREMENTS OF THE FBC FOR THE INSTALLATION OF SMOKE | | DETECTORS. FBC R 314.3.1 | | FBC R 314.3.1 WHEN ALTERATIONS, REPAIRS OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | 5) PROVIDE AND INDICATE THE PROVISIONS FOR A NEW | | CIRCUIT FOR THE MINI SPLIT SYSTEM INDICATED ON THE 1ST | | FLOOR PLAN ON SHEET 1. THE CIRCUIT SHALL BE INDICATED | | IN THE PANEL SCHEDULE AND THE LOAD CALCULATION | | INDICATING THE AVIALABLE CURRENT FOR THE ADDITION OF | | THE NEW CIRCUIT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:22 |
Rev Time |
|
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-09 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-09 |
Time |
06:26 |
Sent To |
|
|
Notes |
2015-06-09 06:27:21 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE | | ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC | | SEC. 107.2.1. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-24 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-24 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2015-06-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-08 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-08 |
Time |
11:47 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-03-18 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-03-18 |
Time |
16:38 |
Sent To |
|
|
Notes |
2015-03-18 16:39:35 | MUST REVISE APPLICATION TO REFLECT CHANGES TO FRONT | | FACADE OF ACCESSORY SRUCTURE. MUST SUBMIT FLOOR PLAN | | AND WINDOW/DOOR SCHEDULE FOR PRIMARY STRUCTURE AND | | CLEAR UNDERSTANDING OF FRAME COLOR AND MUNTIN PATTERN. | | QUESTIONS CONTACT FRIEDERIKE MITTNER AT 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-24 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-23 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-15 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-05-13 |
Time |
16:24 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-02-24 |
Time |
17:57 |
Sent To |
|
|
Notes |
2015-02-25 17:57:50 | SENT TO R25 BIN FOR REVIEW. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-26 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-23 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-23 |
Time |
11:41 |
Sent To |
|
|
Notes |
2015-06-23 11:41:44 | SEE FIRST REVIEW. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2015-06-15 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-15 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-06-15 11:29:06 | SEE FIRST REVIEW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-03-20 |
Time |
12:19 |
Sent To |
|
|
Notes |
2015-03-20 12:20:08 | 1ST REVIEW: FBC 2010 | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-06-09 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-06-09 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:20 |
Rev Time |
|
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-03-20 12:22:20 | 1ST REVIEW: FBC 2010 | | | | APPLICANT HAS DECIDED TO SUBMIT NEW DESIGN DOCUMENTS. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-23 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-23 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-09 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-09 |
Time |
05:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-03-12 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-03-12 |
Time |
04:31 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-12 |
Time |
04:05 |
Sent To |
|
|
Notes |
2015-03-12 04:31:15 | 1) THE DESCRIPTION OF WORK ON THE APPLICATION INCLUDES | | "RE-DO TWO FULL BATHS, RELOCATE LAUNDRY,..." BUT ONLY | | ONE BATHROOM IS SHOWN ON THE SUBMITTED PLANS AND NO | | LAUNDRY ROOM IS SHOWN ON THE PLANS. THERE ARE FOUR SETS | | OF PLANS SHOWING THE SAME THING. CLARIFY. | | 2) SUBMIT A WATER AND SANITARY RISER THAT CLEARLY | | REFLECTS ALL THE CHANGES BEING MADE TO THE SANITARY AND | | WATER SYSTEM, WPB AMEND. TO 2010 FBC SEC. 107.3.5.3. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-03-20 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-03-20 12:19:13 | BY SEPARATE SUBMITTAL |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-24 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-24 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-03-18 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-03-18 |
Time |
16:38 |
Sent To |
|
|
Notes |
2015-03-10 14:01:38 | 3/10/15 |
|
|