|
 |
 |
 |
 |
 |
Plan Review Details - Permit 15020671
Plan Review Stops For Permit 15020671 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-02-24 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-02-24 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-03-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-03-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-03-18 |
Time |
13:46 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-03-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-03-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-03-04 |
Time |
15:23 |
Sent To |
|
|
Notes |
2015-03-05 11:06:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | FIRE PREVENTION SHARES THE SAME COMMENTS AS PLUMBING. | | | | THE INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 54, NATIONAL FUEL CODE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-03-21 |
Time |
06:20 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-13 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-11 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-02-19 |
Time |
18:30 |
Sent To |
|
|
Notes |
2015-02-19 18:31:31 | REVISION SENT TO B25 BIN FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-03-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-11 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-03-11 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-03-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-03-24 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-24 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-03-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-03-21 |
Time |
06:19 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-21 |
Time |
05:52 |
Sent To |
|
|
Notes |
2015-03-21 06:19:45 | 1) INDICATE ON THE PLAN THE TYPE OF PIPE BEING | | INSTALLED FOR THE GAS SYSTEM. THE RESPONSE FROM THE | | ENGINEER REFERS TO PLUMBING SHT. P0.2 BUT THERE IS NO | | SUCH DRAWING IN THE SET OF SUBMITTED PLANS. CLARIFY. | | 2) INDICATE THE DELIVERY PRESSURE OF THE GAS PER THE | | 2010 FBC FUEL GAS CODE SEC.402.2. THE RESPONSE FROM THE | | ENGINEER REFERS TO PLUMBING SHT. P0.2 BUT THERE IS NO | | SUCH DRAWING IN THE SET OF SUBMITTED PLANS. CLARIFY. | | 3) SUBMIT REFERENCED DRAWING P0.2 FOR REVIEW. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-02-23 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-02-23 |
Time |
12:18 |
Sent To |
|
|
Notes |
2015-02-24 12:17:39 | FEB.23, 2015 | | REVISION # 15020671 GAS REVISION | | MASTER PERMIT # 14070406 | | 1)SUBMIT MANUFACTURER?S SPECIFICATIONS /INSTALLATION | | MANUAL FOR ALL NEW AND/OR ADDITIONAL GAS EQUIPMENT | | BEING INSTALLED. WPB AMEND. TO 2010 FBC | | SEC.107.2.1.EQUIPMENT SHALL BE LISTED AND LABELED PER | | THE 2010 FBC FUEL GAS CODE SEC.301.3. | | 2) INDICATE ON THE PLAN THE TYPE OF PIPE BEING | | INSTALLED. WPB AMEND. TO 2010 FBC SEC.107.2.1. | | 3 ) INDICATE THE BTU LOAD OF EACH PIECE OF GAS | | EQUIPMENT AND THE TOTAL BTU LOAD ON THE SYSTEM. | | 4) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2010 | | FBC FUEL GAS CODE SEC.304. | | 5) INDICATE THE DELIVERY PRESSURE OF THE GAS PER THE | | 2010 FUEL GAS CODE SEC.402.2. | | 6) SUBMIT A DETAIL SHOWING THE TYPE, SIZE AND | | TERMINATION LOCATIONS OF ALL GAS VENTS PER THE 2010 FBC | | FUEL GAS CODE SECS.502 THROUGH 505. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |