Plan Review Details - Permit 15020647
Plan Review Stops For Permit 15020647
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-29 Cont ID  
Sent By shill Date 2015-04-29 Time 07:24 Rev Time 0.00
Received By shill Date 2015-04-29 Time 07:24 Sent To  
Notes
2015-04-29 07:24:37OK PER ALANGE
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-13 Cont ID  
Sent By shill Date 2015-03-13 Time 16:07 Rev Time 0.00
Received By shill Date 2015-03-13 Time 16:07 Sent To E
Notes
2015-03-13 16:07:40****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE CALCULATIONS FOR THE FASTENERS, FBC 1609.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-23 Cont ID  
Sent By dhayes Date 2015-03-23 Time 16:01 Rev Time 0.00
Received By dhayes Date 2015-03-23 Time 16:01 Sent To  
Notes
2015-03-23 16:05:043/23/2015
 PROJECT: SUSHIYAMA SIGN
 PERMIT#: 15020647
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION
  
 1) ELECTRIC SIGNS, SECTION SIGNS, AND OUTLINE LIGHTING
 ? FIXED, MOBILE, OR PORTABLE ? SHALL BE LISTED AND
 INSTALLED IN CONFORMANCE WITH THAT LISTING, UNLESS
 OTHERWISE APPROVED BY SPECIAL PERMISSION. 600.3
 LISTING.
  
 2) EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER
 CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE
 LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY
 OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL
 UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN NEC
 600.6(A)(1)
  
 3) ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1
 SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT
 OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR &
 TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME
 SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING
 DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E
 505.2.4
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-29 Cont ID  
Sent By shill Date 2015-04-29 Time 07:24 Rev Time 0.00
Received By shill Date 2015-04-17 Time   Sent To  
Notes
2015-04-17 18:44:12SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-23 Cont ID  
Sent By dhayes Date 2015-03-23 Time 16:02 Rev Time 0.00
Received By dhayes Date 2015-02-19 Time 16:16 Sent To  
Notes
2015-03-13 16:08:023/13 TO ELEC BOX
  
2015-03-13 09:01:43TO MISC 2 BOX.
2015-02-19 16:17:10SENT TO ZONING BIN FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-03-13 Cont ID  
Sent By aaponte Date 2015-03-13 Time 09:01 Rev Time 0.00
Received By aaponte Date 2015-03-13 Time 09:01 Sent To  
Notes
***NONE***