Plan Review Details - Permit 15020621
Plan Review Stops For Permit 15020621 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-04-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-04-06 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-04-06 |
Time |
10:47 |
Sent To |
|
|
Notes |
2015-04-06 11:28:26 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | PROVISO #1: NO ROOM DESIGNATIONS SHOWN FOR THE OPENINGS | | MARKED AS EGRESS. | | | | EMERGENCY MEANS OF ESCAPE FBC R310.4 REQUIRED AND IS TO | | COMPLY WITH THE FOLLOWING: | | | | THE MEANS OF ESCAPE SHALL BE WITHIN THE FIRST FLOOR OF | | THE DWELLING OR DWELLING UNIT AND SHALL NOT BE LOCATED | | WITHIN A GARAGE WITHOUT A SIDE-HINGED DOOR LEADING | | DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART OF THE | | DWELLING OR DWELLING UNIT SHALL BE ABLE TO ACCESS THE | | MEANS OF ESCAPE WITHOUT PASSING THROUGH A LOCKABLE DOOR | | NOT UNDER THEIR CONTROL. | | | | IF THE EMERGENCY MEANS OF ESCAPE SHOWN ON THE PLAN DOES | | NOT COMPLY WITH THIS REQUIREMENT, A REVISION IS | | REQUIRED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-03-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-03 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-03 |
Time |
16:29 |
Sent To |
|
|
Notes |
2015-03-03 16:34:22 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. WOOD IS CIRCLED ON THE ANCHOR CHART SHEET 12, | | CONCRETE SUBSTRATE SPECIFIED. CONCRETE AND CONCRETE | | BLOCK ALSO CIRCLED. INSTALLATION SCHEDULE STATES | | SUBSTRATE IS CONCRETE; MOST CBS STRUCTURES HAVE | | CONCRETE SUBSTRATE ON TOP, BLOCK ON BOTTOM. SUBSTRATE | | NOT CLEAR FBC 2010 RESIDENTIAL 301. | | | | 2. SHUTTER MOUNTING CONNECTION TYPE NOT COMPLETED; THIS | | SHOULD CORRELATE WITH THE ANCHOR CHARTS (C1, C2, C3, | | C4, OR C5). | | | | COMPLETE REVIEW CANNOT BE DONE WITH INFORMATION | | PROVIDED. TOO MANY ITEMS CIRCLED ON SHEET 11 WHICH DO | | NOT CORRELATE WITH THE SPECIFIC JOB CONDITIONS (PER | | INSTALLATION SCHEDULE). | | | | 3. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | INCLUDE THE ROOM DESIGNATION. | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-04-06 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-20 |
Time |
07:06 |
Sent To |
|
|
Notes |
2015-03-20 07:07:03 | TO SH DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-03 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-18 |
Time |
14:40 |
Sent To |
|
|
Notes |
2015-02-18 14:42:06 | ROUTED TO BUILDING $5000 & UNDER |
|
|
|