Plan Review Details - Permit 15020238
Plan Review Stops For Permit 15020238
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-02-13 Cont ID  
Sent By cranford Date 2015-02-13 Time 09:41 Rev Time 0.00
Received By cranford Date 2015-02-12 Time 15:21 Sent To FIRE
Notes
2015-02-13 09:40:52PLEASE DEMONSTRATE THAT THE PROPOSED DRIVEWAY WILL
 COMPLY WITH SECTIONS 94-313 AND 94-482 OF THE CITY'S
 CODE OF ORDINANCES.
  
 THE CITY'S CODE LIMITS RESIDENTIAL LOTS TO ONE ACCESS
 POINT PER FRONTAGE ROAD AND ONE ON THE ALLEY. EACH
 ENTRANCE IS LIMITED TO A 10 FT WIDTH. SECTION
 94-313(1)C.3.(III)
  
 KELLY CRANFORD, PE
 (561)494-1098
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2015-02-13 Cont ID  
Sent By pleduc Date 2015-02-13 Time   Rev Time 0.00
Received By pleduc Date 2015-02-13 Time 15:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-24 Cont ID  
Sent By shill Date 2015-02-24 Time 08:00 Rev Time 0.00
Received By shill Date 2015-02-10 Time 13:54 Sent To  
Notes
2015-02-10 16:34:42R28
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
2015-02-10 13:55:02R20

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-02-12 Cont ID  
Sent By tklarge Date 2015-02-12 Time 05:58 Rev Time 0.00
Received By tklarge Date 2015-02-12 Time 04:21 Sent To  
Notes
2015-02-12 06:04:391) THERE IS AN UNVENTED SINK SHOWN ON THE PLUMBING
 RISER IN THE GARAGE BUT THE SINK IS NOT SHOWN ON THE
 FLOOR PLAN. CLARIFY. FIXTURES SHALL BE VENTED PER THE
 2010 FBCR SEC.P3101.2 & P3101.2.1.
 2) THE LAYOUT OF THE FIXTURES ON THE RISER DIAGRAM DOES
 NOT CORRELATE WITH THE FLOOR PLAN. WPB AMEND. TO 2010
 FBC SEC. 107.2.1.
 3) SIZE ALL THE VENTS ON THE PLUMBING RISER. WPB AMEND.
 TO 2010 FBCR 107.2.1.
 4) THE WASHING MACHINE IS NOT VENTED. 2010 FBCR
 SEC.P3101.2 & P3101.2.1.
 5) THERE IS AN UNVENTED SINK SHOWN ON THE RISER FOR THE
 GARAGE BUT THE SINK IS NOT SHOWN ON THE FLOOR PLAN.
 CLARIFY.
 6) THERE IS A TUB AND WATER CLOSET SHOWN ON THE SECOND
 FLOOR OF THE MAIN HOUSE MASTER BATH BUT NOT SHOWN ON
 THE RISER. CLARIFY.
 7) THE LAVATORY & SINK ON THE 2ND FLOOR GARAGE RISER
 CANNOT CONNECT TO THE SAME FIXTURE DRAIN.COMPLY WITH
 2010 FBCR SEC.P3201.6. EACH FIXTURE SHALL CONNECT
 SEPARATELY TO THE STACK.
 8) THE SECOND FLOOR BATH CNNOT DISCHARGE INTO THE SOIL
 STACK AS DESIGNED. 2010 FBCR SEC.P3108.4.
 9) SHOW THE DIMENSIONS OF ALL SHOWERS (LXW). SHOWERS
 SHALL COMPLY WITH 2010 FBCR SEC. P 2708.1. SHOWERS
 SHALL HAVE A MINIMUM CLEAR AND UNOBSTRUCTED FINISHED
 WIDTH OF 22 INCHES PER 2010 FBCR SEC.P2708.1.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***