Plan Review Stops For Permit 15020147 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-09 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-09 |
Time |
14:27 |
Sent To |
|
|
Notes |
2015-06-09 14:29:49 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- SUBMIT NEW ENERGY CALCULATIONS. GLASS AREA IN ITEM | | #6C IS MORE THAN 20%. PRESCRIPTIVE FORM 402 CAN'T BE | | USED. NEED TO USE PERFORMANCE FORM 405. ALSO, WALLS AND | | CEILING INSULATION VALUES NEED TO MATCH PLANS. | | COORDINATE WITH PLANS AS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-06-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-03 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-03 |
Time |
09:35 |
Sent To |
|
|
Notes |
2015-06-03 09:36:30 | RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- ENERGY CALCULATIONS SUBMITTED (SEC. 103.2.2 OF 2010 | | FBC-ENERGY CONSERVATION). | | A) FORM 402-2010 CAN NOT BE USED IF THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SEE GENERAL INSTRUCTIONS NOTE #1 | | ON TOP OF FORM SUBMITTED. | | | | B) COMPLETE ALL THE INFORMATION ON TABLE 402A ON PAGE 2 | | OF FORM SUBMITTED. THE INSTALLED VALUES MUST MEET OR | | EXCEED THE PERFORMANCE CRITERIA. AND, REVISE ALL THE | | INFORMATION ON PAGE ONE OF FORM SUBMITTED. SEE GENERAL | | INSTRUCTION #2 ON TOP OF FORM SUBMITTED. | | | | C) REVISE ITEM #6C. GLASS AREA TO MATCH PLANS. NEED TO | | INCLUDE ALL NEW WINDOWS AND EXISTING WINDOWS. | | | | D) REVISE ITEM #9. WALL TYPE DOESN'T MATCH PLANS. | | | | E) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY | | AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT FOR | | THE CONSTRUCTION AND DESIGN PROFESSIONAL FEES. (REPEAT | | COMMENT. NOT ADDRESSED). | | | | 3- CLARIFY WHY SUBMITTING NOA 11-1013.14 FOR SINGLE | | HUNG WINDOWS. THERE IS NOT SINGLE HUNG WINDOWS ON THIS | | PROJECT. SEC. 107.2.1 CITY AMENDMENTS. | | | | 4- EXTERIOR BLOCK WALL SECTION 1/A.01: | | A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | COMPLIANCE WITH R-11 INSULATION ON A CONCRETE BLOCK | | WALL AS SPECIFIED ON THE WALL SECTION. NOTE: COORDINATE | | WITH THE ENERGY CALCULATIONS, INCLUDING THE CEILING R | | VALUE. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. | | REVISED WALL SECTION DOESN'T COMPLY. | | R-VALUE GIVEN TO THE WALL IS FOR THE R-VALUE OF THE | | ADDED INSULATION ONLY. "THE R-VALUES OF STRUCTURAL | | BUILDING MATERIALS SUCH AS FRAMING MEMBERS, CONCRETE | | BLOCKS OR GYPSUM BOARD SHALL NOT BE INCLUDED.". SEE | | SEC. 304.1.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | NOTE: 3/4" DOW "TUFF-R" PROVIDES ONLY R-5 VALUE. | | PROVIDE ICC EVALUATION REPORT FOR THIS TYPE OF | | INSULATION SHOWING COMPLIANCE WITH SEC. R316. KEEP IN | | MIND THAT THIS PRODUCT IS USUALLY INSTALLED ON THE | | EXTERIOR SIDE OF THE WALL. SEE ESR-3089 REPORT. REVISE | | WALL SECTION DETAIL AS REQUIRED. | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561) 805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-05-18 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-05-18 |
Time |
14:50 |
Sent To |
|
|
Notes |
2015-05-18 15:01:49 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. (REPEAT | | COMMENT. NOT ADDRESSED). | | NOTE: ENERGY CALCULATIONS AND EQUIPMENT LOAD | | CALCULATIONS ARE TWO DIFFERENT THINGS. THE PERMIT CAN | | NOT BE ISSUED WITHOUT THE ENERGY CALCULATIONS | | COMPLIANCE CERTIFICATION. SEC. 103.2.3.2 OF 2010 | | FBC-ENERGY CONSERVATION. | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY | | AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT FOR | | THE CONSTRUCTION AND DESIGN PROFESSIONAL FEES. (REPEAT | | COMMENT. NOT ADDRESSED). | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR THE PRE-CAST LINTEL FOR NEW FIXED | | WINDOW. (REPEAT COMMENT. NOT ADDRESSED). | | | | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE | | PRODUCT APPROVAL. SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 5- EXTERIOR BLOCK WALL SECTION 1/A.01: | | A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | COMPLIANCE WITH R-11 INSULATION ON A CONCRETE BLOCK | | WALL AS SPECIFIED ON THE WALL SECTION. NOTE: COORDINATE | | WITH THE ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010 | | FBC-ENERGY CONSERVATION. REVISED WALL SECTION DOESN'T | | COMPLY. | | R-VALUE GIVEN TO THE WALL IS FOR THE R-VALUE OF THE | | ADDED INSULATION ONLY. "THE R-VALUES OF STRUCTURAL | | BUILDING MATERIALS SUCH AS FRAMING MEMBERS, CONCRETE | | BLOCKS OR GYPSUM BOARD SHALL NOT BE INCLUDED.". SEE | | SEC. 304.1.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561) 805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-03-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-03-13 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-03-13 |
Time |
15:46 |
Sent To |
|
|
Notes |
2015-03-13 16:08:25 | RESIDENTIAL (R3) GARAGE ALTERATION, BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- CONVERTING GARAGE TO LIVING SPACE: BRING PLANS TO | | PALM BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | CODE. | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION AND SEC. 101.5 | | OF 2010 FBC-EXISTING BUILDING. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY | | AMENDMENTS TO FBC. REVISE VALUATION AS REQUIRED. OR | | PROVIDE COPY OF SIGNED CONTRACT FOR THE CONSTRUCTION | | AND DESIGN PROFESSIONAL FEES. | | | | 4- THESE PLANS ARE NOT TO BE USED FOR CONSTRUCTION. SEE | | STATEMENT AT THE BOTTOM LEFT OF SHEET A.01: | | "PRELIMINARY SET - NOT FOR CONSTRUCTION". PROVIDE PLANS | | THAT ARE READY FOR BUILDING PERMITS AND CONSTRUCTION. | | SEC. 107.2.1 CITY AMENDMENTS. TO FBC. | | | | 5- ARCHITECT TO SPECIFY ALTERATION LEVEL TYPE AS | | REQUIRED BY SEC. 401.4 OF 2010 FBC EXISTING BUILDING. | | | | 6- ARCHITECT TO PROVIDE INFORMATION SHOWING COMPLIANCE | | WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF 2010 | | FBC-RESIDENTIAL. | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) ALL WINDOW TYPES SPECIFIED ON PLANS. | | | | B) PRECAST LINTELS SPECIFIED ON NEW WINDOW/DOOR BUCK | | DETAIL. | | | | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 9- EXTERIOR BLOCK WALL SECTION 1/A.01: | | A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | COMPLIANCE WITH R-11 INSULATION ON A CONCRETE BLOCK | | WALL AS SPECIFIED ON THE WALL SECTION. NOTE: COORDINATE | | WITH THE ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010 | | FBC-ENERGY CONSERVATION. | | | | B) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R302.11 OF | | 2010 FBC-RESIDENTIAL. | | | | 10- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE | | WITH THE HEATING REQUIREMENTS OF SEC. R303.8 OF 2010 | | FBC-RESIDENTIAL. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561) 805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-06-09 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-06-09 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-20 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-20 |
Time |
07:00 |
Sent To |
|
|
Notes |
2015-03-20 07:40:25 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | RE-INSPECTION FEE(S). |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-09 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-09 |
Time |
14:25 |
Sent To |
|
|
Notes |
2015-06-09 14:27:10 | 6/9/15 MET WITH ANTHONY HARRINGTON (ARCH) AND TALKED TO | | PAOLO WESTON. I WILL ISSUE PERMIT WITH PROVISO. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-06-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-03 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-05-26 |
Time |
09:35 |
Sent To |
|
|
Notes |
2015-06-03 09:35:42 | THIRD RE-SUBMITTAL. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-05-18 |
Time |
18:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-28 |
Time |
14:40 |
Sent To |
|
|
Notes |
2015-04-28 14:41:20 | RE-SUBMITTAL SENT TO JULIO GOMEZ FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-20 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-02-05 |
Time |
18:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-05-18 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-05-18 |
Time |
15:20 |
Sent To |
|
|
Notes |
2015-05-18 15:21:41 | $236.59 PAID. MU-2015-008360. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-03-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-03-13 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-03-13 |
Time |
15:49 |
Sent To |
|
|
Notes |
2015-03-13 15:52:19 | 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) FOR | | IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED PLANS | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY | | THE COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | DEVELOPMENT CODE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-05-18 |
Time |
18:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-05-18 |
Time |
18:18 |
Sent To |
|
|
Notes |
2015-05-18 18:19:13 | NO INFORMATION SUBMITTED AT THIS TIME. PROVIDE COMPLETE | | INFORMATION UNDER A SEPARATE PERMIT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-03-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-03-13 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-03-13 |
Time |
17:22 |
Sent To |
|
|
Notes |
2015-03-13 17:28:10 | RESIDENTIAL (R3) GARAGE ALTERATION, MECHANICAL REVIEW | | COMMENTS. | | CODE: 2010 FBC | | | | 1- NO INFORMATION SUBMITTED FOR MECHANICAL REVIEW. | | PROVIDE COMPLETE INFORMATION. SEC. 107.3.5.3(10) OF | | CITY AMENDMENTS TO FBC. | | | | 2- HEATING IS REQUIRED FOR ALL HABITABLE ROOMS. SEE | | BUILDING REVIEW COMMENTS. SEC. R303.8 OF 2010 | | FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561) 805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2015-02-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-02-07 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-02-07 |
Time |
08:27 |
Sent To |
|
|
Notes |
2015-02-07 08:31:43 | CONNECTING NEW WASHER TO EXISTING PLUMBING .NO PLUMBING | | CHANGES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-06-09 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-06-09 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-02-19 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-02-19 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-02-19 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|