Plan Review Details - Permit 15020128
Plan Review Stops For Permit 15020128 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-04-07 |
Time |
18:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-04-07 |
Time |
18:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-03-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-03 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-03 |
Time |
15:27 |
Sent To |
|
|
Notes |
2015-03-03 15:34:55 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. REVISE FLOOR PLAN TO INCLUDE THE FOLLOWING | | INFORMATION: WINDOW LOCATIONS, SIZES, WINDOW TYPE, ROOM | | DESIGNATIONS. | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT: | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | - AWNING, CASEMENT, SINGLE HUNG? | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | WINDOW IS FULLY OPEN. | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-03-18 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-03-18 |
Time |
14:39 |
Sent To |
|
|
Notes |
2015-03-18 14:41:03 | WHITE FRAMES, CLEAR GLASS, EITHER 1/1, 3/1 OR 6/1 SH | | OK. QUESTIONS, CONTACT FRIEDETIKE MITTNER AT 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-04-07 |
Time |
18:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-24 |
Time |
08:38 |
Sent To |
|
|
Notes |
2015-03-25 08:38:42 | RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-04-07 |
Time |
18:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-03 |
Time |
15:42 |
Sent To |
|
|
Notes |
2015-03-06 16:49:54 | 3/6 TO ZONING FOR HISTORIC REVIEW | | | 2015-03-03 15:42:35 | TO ZONING FOR HISTORIC REVIEW | | | 2015-02-04 13:49:01 | ROUTED TO MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy