Plan Review Details - Permit 15020022
Plan Review Stops For Permit 15020022
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-02-23 Cont ID  
Sent By jwitmer Date 2015-02-23 Time   Rev Time  
Received By jwitmer Date 2015-02-23 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-03-31 Cont ID  
Sent By rlecky Date 2015-03-31 Time 12:24 Rev Time 0.00
Received By rlecky Date 2015-03-31 Time 12:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-02-12 Cont ID  
Sent By rlecky Date 2015-02-12 Time 12:34 Rev Time 0.00
Received By rlecky Date 2015-02-12 Time 10:37 Sent To  
Notes
2015-02-12 11:02:29 
 15020022
 2601 OKEECHOBEE BLVD.
 BURLINGTON
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 IT IS NOT CLEAR IF THE ELECTRICAL SERVICE IS REPLACING
 AN EXISTING SERVICE OR IF A NEW ELECTRICAL SERVICE IS
 BEING PROPOSED. VERIFY THIS BUILDING/TENANT HAS
 SUFFICIENT FIRE SEPARATION TO QUALIFY AS A SEPARATE
 BUILDING AND TO HAVE ITS OWN ELECTRICAL SERVICE OR
 PROVIDE JUSTIFICATION FOR THE SERVICE PROPOSED. NEC
 230.2, 215.5, 230.71
  
 INDICATE THE REQUIRED FAULT CURRENT RATING FOR THE
 ELECTRICAL SERVICE AND PANELBOARDS. NEC 110.9, 110.10,
  
 ON THE ELECTRICAL PLAN PROVIDE A SAFETY LABELING
 SCHEDULE FOR FLASH PROTECTION FOR THE SERVICE, PANEL
 BOARDS AND MAIN DISCONNECTING MEANS. NEC 110.22
  
 PROVIDE A PERMANENT IDENTIFICATION PLAQUE WHICH SHOWS
 THE LOCATION OF THE ELECTRICAL SERVICES AND MAIN
 DISCONNECTS FOR THIS MULTIPLE OCCUPANCY BUILDING. NEC
 230.2 (E)
  
 PROVIDE A LIGHTING DENSITY SUMMARY ON THE ELECTRIC PLAN
 WHICH SHOWS COMPLIANCE WITH THE FLORIDA BUILDING ENERGY
 CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.5;
 505.5.3; T. 505.5.3
  
 PROVIDE A NOTE ON PLANS REGARDING THE LIMITATIONS OF
 USE FOR MULTI-WIRE BRANCH CIRCUITS. NEC 210.4, 605.8(D)
  
 PROVIDE A NOTE ON PLANS REGARDING THE VOLTAGE
 LIMITATIONS AND VOLTAGE SEPARATION WITH BARRIERS
 REQUIRED FOR SWITCHES AND ADJACENT DEVICES. NEC 404.8
  
 NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR ALARM
 SYSTEMS, SECURITY, VOICE AND DATA SYSTEMS.
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-02-10 Cont ID  
Sent By scaldero Date 2015-02-10 Time 16:36 Rev Time 0.00
Received By scaldero Date 2015-02-10 Time 16:23 Sent To  
Notes
2015-02-10 16:36:06PERMIT # 15020022
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVISO:
  
 1) UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 2) PER LOCAL AHJ POLICY, DUCT SMOKE DETECTORS SHALL
 INITIATE A GENERAL FIRE ALARM CONDITION. (REFERS TO
 FIRE ALARM NOTE ON SHEET A1.5)
  
 SUE ELLEN CALDERON
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 644-7326
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-31 Cont ID  
Sent By rlecky Date 2015-03-31 Time 12:24 Rev Time 0.00
Received By rlecky Date 2015-03-12 Time 12:07 Sent To  
Notes
2015-03-13 12:14:43C26
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-02 Cont ID  
Sent By hmoser Date 2015-03-02 Time 09:15 Rev Time 0.00
Received By hmoser Date 2015-02-02 Time 14:52 Sent To  
Notes
2015-02-03 14:54:04SENT TO C19 BIN FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-03-20 Cont ID  
Sent By hmoser Date 2015-03-20 Time 14:54 Rev Time 0.00
Received By hmoser Date 2015-03-20 Time 14:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-03-02 Cont ID  
Sent By hmoser Date 2015-03-02 Time 08:44 Rev Time 0.00
Received By hmoser Date 2015-02-28 Time 10:51 Sent To  
Notes
2015-03-02 08:44:00PASS PROVISO
 1) REFER TO SECTION 503.2.5.4 SHUTOFF DAMPER CONTROLS
 2010 FLORIDA ENERGY CODE 2010
 2) DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL ALARM
 606.4.1 SUPERVISION. FBC (M) 2010
 3) REFER TO SECTION 304.11 GUARDS. FOR EQUIPMENT
 LOCATED LESS THAN 10 FT FROM THE EDGE OF THE ROOF.
 FBC (M) 2010
 4) REFER TO SECTION 307.2.3.1 WATER LEVEL MONITORING
 DEVICE FBC (M) 2010
 5) REFER TO SECTION 603.5 NONMETALLIC DUCTS. DO NOT
 PAINT FIBERGLASS OR FLEX DUCT 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-02-07 Cont ID  
Sent By tklarge Date 2015-02-07 Time 03:03 Rev Time 0.00
Received By tklarge Date 2015-02-05 Time 07:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-03-20 Cont ID  
Sent By llouie Date 2015-03-17 Time 10:14 Rev Time 0.00
Received By llouie Date 2015-03-16 Time 17:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-02-11 Cont ID  
Sent By llouie Date 2015-02-11 Time 16:41 Rev Time 0.00
Received By llouie Date 2015-02-11 Time 16:41 Sent To  
Notes
2015-02-11 16:45:43** ZONING FAILED **
  
 1.) APPROVAL OF APPLICATION PB1520 I AND J REQUIRED
 PRIOR TO BUILDING PERMIT.
  
  
 PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE
 ARE QUESTIONS.
2015-02-10 10:35:152/10/15