Plan Review Stops For Permit 15020022 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-02-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-02-23 |
Time |
|
Rev Time |
|
Received By |
jwitmer |
Date |
2015-02-23 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-03-31 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-03-31 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-03-31 |
Time |
12:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-02-12 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-02-12 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-02-12 |
Time |
10:37 |
Sent To |
|
|
Notes |
2015-02-12 11:02:29 | | | 15020022 | | 2601 OKEECHOBEE BLVD. | | BURLINGTON | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENTS. | | | | IT IS NOT CLEAR IF THE ELECTRICAL SERVICE IS REPLACING | | AN EXISTING SERVICE OR IF A NEW ELECTRICAL SERVICE IS | | BEING PROPOSED. VERIFY THIS BUILDING/TENANT HAS | | SUFFICIENT FIRE SEPARATION TO QUALIFY AS A SEPARATE | | BUILDING AND TO HAVE ITS OWN ELECTRICAL SERVICE OR | | PROVIDE JUSTIFICATION FOR THE SERVICE PROPOSED. NEC | | 230.2, 215.5, 230.71 | | | | INDICATE THE REQUIRED FAULT CURRENT RATING FOR THE | | ELECTRICAL SERVICE AND PANELBOARDS. NEC 110.9, 110.10, | | | | ON THE ELECTRICAL PLAN PROVIDE A SAFETY LABELING | | SCHEDULE FOR FLASH PROTECTION FOR THE SERVICE, PANEL | | BOARDS AND MAIN DISCONNECTING MEANS. NEC 110.22 | | | | PROVIDE A PERMANENT IDENTIFICATION PLAQUE WHICH SHOWS | | THE LOCATION OF THE ELECTRICAL SERVICES AND MAIN | | DISCONNECTS FOR THIS MULTIPLE OCCUPANCY BUILDING. NEC | | 230.2 (E) | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE ELECTRIC PLAN | | WHICH SHOWS COMPLIANCE WITH THE FLORIDA BUILDING ENERGY | | CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.5; | | 505.5.3; T. 505.5.3 | | | | PROVIDE A NOTE ON PLANS REGARDING THE LIMITATIONS OF | | USE FOR MULTI-WIRE BRANCH CIRCUITS. NEC 210.4, 605.8(D) | | | | PROVIDE A NOTE ON PLANS REGARDING THE VOLTAGE | | LIMITATIONS AND VOLTAGE SEPARATION WITH BARRIERS | | REQUIRED FOR SWITCHES AND ADJACENT DEVICES. NEC 404.8 | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR ALARM | | SYSTEMS, SECURITY, VOICE AND DATA SYSTEMS. | | | | ROBERT LECKY, CBO | | ELECTRICAL PLANS REVIEW | | 561-373-3701 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-02-10 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-02-10 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-02-10 |
Time |
16:23 |
Sent To |
|
|
Notes |
2015-02-10 16:36:06 | PERMIT # 15020022 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PROVISO: | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | AMENDMENTS. | | | | 2) PER LOCAL AHJ POLICY, DUCT SMOKE DETECTORS SHALL | | INITIATE A GENERAL FIRE ALARM CONDITION. (REFERS TO | | FIRE ALARM NOTE ON SHEET A1.5) | | | | SUE ELLEN CALDERON | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 644-7326 | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-31 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-03-31 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-03-12 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-02 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-02-02 |
Time |
14:52 |
Sent To |
|
|
Notes |
2015-02-03 14:54:04 | SENT TO C19 BIN FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-20 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-03-20 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-03-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-02 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-02-28 |
Time |
10:51 |
Sent To |
|
|
Notes |
2015-03-02 08:44:00 | PASS PROVISO | | 1) REFER TO SECTION 503.2.5.4 SHUTOFF DAMPER CONTROLS | | 2010 FLORIDA ENERGY CODE 2010 | | 2) DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL ALARM | | 606.4.1 SUPERVISION. FBC (M) 2010 | | 3) REFER TO SECTION 304.11 GUARDS. FOR EQUIPMENT | | LOCATED LESS THAN 10 FT FROM THE EDGE OF THE ROOF. | | FBC (M) 2010 | | 4) REFER TO SECTION 307.2.3.1 WATER LEVEL MONITORING | | DEVICE FBC (M) 2010 | | 5) REFER TO SECTION 603.5 NONMETALLIC DUCTS. DO NOT | | PAINT FIBERGLASS OR FLEX DUCT 2010 FBC (M) | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-02-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-02-07 |
Time |
03:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-02-05 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-03-20 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2015-03-17 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2015-03-16 |
Time |
17:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-02-11 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2015-02-11 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2015-02-11 |
Time |
16:41 |
Sent To |
|
|
Notes |
2015-02-11 16:45:43 | ** ZONING FAILED ** | | | | 1.) APPROVAL OF APPLICATION PB1520 I AND J REQUIRED | | PRIOR TO BUILDING PERMIT. | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE | | ARE QUESTIONS. | 2015-02-10 10:35:15 | 2/10/15 |
|
|