Plan Review Details - Permit 15020001
Plan Review Stops For Permit 15020001 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-03-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-19 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-19 |
Time |
09:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-03-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-18 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-12 |
Time |
18:01 |
Sent To |
|
|
Notes |
2015-03-12 18:18:25 | PLAN REVIEW COMMENTS | | | | 2ND REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE NOA THAT WAS SUBMITTED FOR THE SINGLE HUNG | | WINDOWS (NOA NO. 12-0127.16) WAS SUPERSEDED BY NOA NO. | | 14-0908.10 ON NOVEMBER 06, 2014. SUBMIT TWO COPIES OF | | THE CURRENT PRODUCT APPROVAL. | | | | 2) THE NOA THAT WAS SUBMITTED FOR THE STRUCTURAL | | MULLIONS (NOA NO. 12-0127.07) WAS SUPERSEDED BY NOA NO. | | 14-0908.08 ON NOVEMBER 06, 2014. THE INSTALLATION | | INSTRUCTION SHEETS WERE NOT SHRUNK TO FIT ON THE 8.5" X | | 11" PAPER AND SOME OF THE INFORMATION IS MISSING. MARK | | THE SIZES AND PRESSURES ON THE PRODUCT APPROVAL FOR THE | | MULLIONS THAT WILL BE USED. FBC 107.3.4 & DCA RULE 9N-3 | | | | 3) SPECIFY THE DESIGN PRESSURE AND THE GLASS TYPE FOR | | THE WINDOWS BY MARKING THEM ON THE PRODUCT APPROVALS. | | FBC 107.3.4 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-02-24 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-02-24 |
Time |
15:42 |
Sent To |
|
|
Notes |
2015-02-24 16:24:54 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE NOA THAT WAS SUBMITTED FOR THE SINGLE HUNG | | WINDOWS HAS BEEN SUPERSEDED. THE CURRENT ONE IS NOA NO. | | 14-0908.09. | | | | 2) IT APPEARS THAT SOME OF THE WINDOWS ARE DOUBLES THAT | | ARE CONNECTED WITH A STRUCTURAL MULLION. PLEASE | | CLARIFY. SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | STRUCTURAL MULLIONS. MARK THE SIZES AND PRESSURES ON | | THE PRODUCT APPROVAL FOR THE ONES THAT WILL BE USED. | | FBC 107.3.4 & DCA RULE 9N-3 | | | | 3) SPECIFY THE DESIGN PRESSURE AND THE GLASS TYPE FOR | | THE WINDOWS BY MARKING THEM ON THE PRODUCT APPROVALS. | | FBC 107.3.4 | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-02-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-02-02 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-02-02 |
Time |
08:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-19 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-18 |
Time |
11:05 |
Sent To |
|
|
Notes |
2015-03-18 11:05:51 | SENT TO R MCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-03-18 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-12 |
Time |
08:12 |
Sent To |
B |
|
Notes |
|
|
|