Plan Review Details - Permit 15010988
Plan Review Stops For Permit 15010988
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-02-18 Cont ID  
Sent By rmcdouga Date 2015-02-18 Time 13:41 Rev Time 0.00
Received By rmcdouga Date 2015-02-18 Time 11:13 Sent To E
Notes
2015-02-18 13:32:35PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SHOW THAT THE GUEST HOUSE COMPLIES WITH FBC-R314.3.1
 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
  
 2) SHOW THAT THE GUEST HOUSE COMPLIES WITH FBC-R315.1
 CARBON MONOXIDE PROTECTION.
 EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING
 BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS
 ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR
 APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER
 FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE
 AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL
 CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH
 ROOM USED FOR SLEEPING PURPOSES.
  
 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING,
 WINDOW, MULLION AND DOOR SUBMITTALS.
  
 4) SHOW COMPLIANCE WITH FBC 1503.4.2.1 OVERFLOW
 SCUPPERS.
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT
 PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR
 PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4
 INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND
 SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED
 VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET
 SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-02-19 Cont ID  
Sent By dhayes Date 2015-02-19 Time 16:52 Rev Time 0.00
Received By dhayes Date 2015-02-19 Time 15:45 Sent To  
Notes
2015-02-19 16:52:072/19/2015
 PROJECT: RIVERA
 PERMIT#: 15010988
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) REVISE THE RISER DIAGRAM TO INDICATE A SINGLE
 GROUNDING ELECTRODE CONDUCTOR SIZED IN ACCORDANCE WITH
 NEC 250.66 TO ONE COMMON GROUNDING ELECTRODE SYSTEM.
 NEC 250.66
  
 2) AN INTERSYSTEM BONDING TERMINATION FOR CONNECTING
 INTERSYSTEM BONDING AND GROUNDING CONDUCTORS REQUIRED
 FOR OTHER SYSTEMS SHALL BE PROVIDED EXTERNAL TO
 ENCLOSURES AT THE SERVICE EQUIPMENT AND AT THE
 DISCONNECTING MEANS FOR ANY ADDITIONAL BUILDINGS OR
 STRUCTURES. NEC 250.94.
  
 3) EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE
 LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND
 SPECIFIC PURPOSE OR USE. NEC 408.4
  
 4) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS
 HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT
 NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE
 INTERRUPTED. NEC 110.9
  
 5) OCPD?S SHALL NOT BE LOCATED IN THE VICINITY OF
 EASILY IGNITIBLE MATERIAL, SUCH AS IN CLOTHES CLOSETS.
 NEC 240.24(B)(2)(D)
  
 6) PROVIDE SPECS ON TANKLESS WATER HEATERS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-02-03 Cont ID  
Sent By fmittner Date 2015-02-03 Time 09:42 Rev Time 0.00
Received By fmittner Date 2015-02-03 Time 09:42 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-19 Cont ID  
Sent By dhayes Date 2015-02-19 Time 16:52 Rev Time 0.00
Received By dhayes Date 2015-01-28 Time 16:08 Sent To  
Notes
2015-02-04 16:11:19R20
2015-01-28 15:52:15ROUTED TO HISTORIC ~NSD

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-02-18 Cont ID  
Sent By rmcdouga Date 2015-02-18 Time 07:58 Rev Time 0.00
Received By rmcdouga Date 2015-02-18 Time 07:58 Sent To  
Notes
2015-02-18 08:03:38CONVERTING FROM STORAGE TO HABITABLE SPACE. BEFORE A
 PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES MUST BE
 PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE SET OF
 PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM BEACH
 COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH THE
 IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT MUST BE
 RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE THE
 BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-02-18 Cont ID  
Sent By rmcdouga Date 2015-02-18 Time 09:18 Rev Time 0.00
Received By rmcdouga Date 2015-02-18 Time 08:35 Sent To  
Notes
2015-02-18 08:43:16PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC ENERGY CONSERVATION - SECT. 403.6.1 EQUIPMENT
 SIZING.
 HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN
 ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH MANUAL J OR OTHER
 APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES,
 BASED ON BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION
 OF THE BUILDING. THE MANUFACTURER AND MODEL NUMBER OF
 THE OUTDOOR AND INDOOR UNITS (IF SPLIT SYSTEM) SHALL BE
 SUBMITTED ALONG WITH THE SENSIBLE AND TOTAL COOLING
 CAPACITIES AT THE DESIGN CONDITIONS DESCRIBED IN
 SECTION 302.1. THIS CODE DOES NOT ALLOW DESIGNER SAFETY
 FACTORS, PROVISIONS FOR FUTURE EXPANSION OR OTHER
 FACTORS WHICH AFFECT EQUIPMENT SIZING. SYSTEM SIZING
 CALCULATIONS SHALL NOT INCLUDE LOADS CREATED BY LOCAL
 INTERMITTENT MECHANICAL VENTILATION SUCH AS STANDARD
 KITCHEN AND BATHROOM EXHAUST SYSTEMS. PROVIDE EQUIPMENT
 SIZING CALCULATIONS.
  
 2) FBC - 107.3.5.3 PROVIDE A MECHANICAL PLAN TO SHOW
 SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R
 M15.
  
 3) FBC -107.3.5.1.4 MECHANICAL MINIMUM PLAN REVIEW
 CRITERIA: SHOW, EXHAUST SYSTEMS, CLOTHES DRYER EXHAUST,
 KITCHEN EQUIPMENT EXHAUST, SPECIALTY EXHAUST SYSTEMS,
 EQUIPMENT, EQUIPMENT LOCATION, MAKE-UP AIR,
 ROOF-MOUNTED EQUIPMENT, DUCT SYSTEMS, VENTILATION,
 COMBUSTION AIR, CHIMNEYS, FIREPLACES AND VENTS,
 APPLIANCES, BOILERS, REFRIGERATION, BATHROOM
 VENTILATION, LABORATORY, DESIGN FLOOD ELEVATION.
  
 4) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND
 SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN
 AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT
 CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS.
  
 5) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT
 BEDROOMS.
  
 6) M1602.2 PROHIBITED SOURCES. OUTDOOR AND RETURN AIR
 FOR A FORCED-AIR HEATING OR COOLING SYSTEM SHALL NOT BE
 TAKEN FROM THE FOLLOWING LOCATIONS:
 4. A CLOSET, BATHROOM, TOILET ROOM, KITCHEN, GARAGE,
 MECHANICAL ROOM, BOILER ROOM, FURNACE ROOM,
 UNCONDITIONED ATTIC OR OTHER DWELLING UNIT.
 THE PROPOSED FLOOR PLAN ON SHEET A-1 SHOWS THE NEW AIR
 HANDLER LOCATED IN A CLOSET IN THE KITCHEN.
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-02-13 Cont ID  
Sent By tklarge Date 2015-02-13 Time 10:59 Rev Time 0.00
Received By tklarge Date 2015-02-13 Time 09:26 Sent To  
Notes
2015-02-13 11:00:03SEPARATE PERMIT REQD. FOR GAS.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-02-03 Cont ID  
Sent By fmittner Date 2015-02-03 Time 09:42 Rev Time 0.00
Received By fmittner Date 2015-02-03 Time 09:42 Sent To  
Notes
***NONE***