Plan Review Details - Permit 15010921
Plan Review Stops For Permit 15010921 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-01-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-29 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-29 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-02-11 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-02-11 |
Time |
06:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-01-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-29 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-29 |
Time |
12:56 |
Sent To |
|
|
Notes |
2015-01-29 13:02:40 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRICAL | | | | SUBMIT TWO SETS OF SIGNED AND SEALED ELECTRICAL PLAN | | SHEETS E1.0 AND E2.0. FS 471 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-01-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-28 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-28 |
Time |
07:41 |
Sent To |
B |
|
Notes |
2015-01-29 13:05:33 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRICAL | | | | THESE ARE "MASTER" PLANS CORRECTIONS MUST BE SUBMITTED | | FOR REVIEW. SUBMIT TWO SETS OF SIGNED AND SEALED | | ELECTRICAL PLAN SHEETS E1.0 AND E2.0. FS 471 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2015-01-28 07:47:26 | APPROVED WITH EXCEPTION. | | PROVIDE SIGNED AND SEALED SHEET E1.0 TO INSPECTOR FOR | | FINAL INSPECTION. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-02-11 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-02-03 |
Time |
11:13 |
Sent To |
M |
|
Notes |
2015-02-05 11:14:49 | TO ROBERT MCDOUGAL'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-29 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-01-29 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-27 |
Time |
07:40 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-02-11 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-02-11 |
Time |
06:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-01-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-29 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-29 |
Time |
13:06 |
Sent To |
|
|
Notes |
2015-01-29 13:20:52 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | | | 1) SUBMIT TWO SETS OF SIGNED AND SEALED REVISED | | MECHANICAL PLAN SHEETS M-1A, M-1B, M-1C, M-1D AND M-1F. | | THE APPROVED MECHANICAL PLANS WERE SIGNED AND SEALED BY | | STEPHEN WALSH, P.E. | | | | 2) THE ENERGY CALCULATIONS FOR THE "MASTER" PLAN SHOULD | | BE WORST CASE. THE ENERGY CALCULATIONS AND EQUIPMENT | | SIZING CALCULATIONS FOR EACH OF THE SPECIFIC BUILDINGS | | "BABIES" ARE REQUIRED TO BE SITE SPECIFIC BASED ON THE | | BUILDING ORIENTATION. FBC ENERGY CONSERVATION 403.6 |
|
|
|