Plan Review Details - Permit 15010890
Plan Review Stops For Permit 15010890
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-02-24 Cont ID  
Sent By jgomez Date 2015-02-24 Time 07:51 Rev Time 0.00
Received By jgomez Date 2015-02-24 Time 07:43 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-01-27 Cont ID  
Sent By jgomez Date 2015-01-27 Time 12:49 Rev Time 0.00
Received By jgomez Date 2015-01-27 Time 12:49 Sent To  
Notes
2015-01-27 12:52:36SEE COMMENTS ON REVIEW STOP #1. THIS STOP WAS ADDED
 BECAUSE REVIEW STOP #1 WAS BLOCKED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-27 Cont ID  
Sent By jgomez Date 2015-01-27 Time 12:53 Rev Time 0.00
Received By jgomez Date 2015-01-27 Time 12:39 Sent To  
Notes
2015-01-27 12:53:01RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ENGINEER INFORMATION SUBMITTED IS INSUFFICIENT FOR
 PLAN REVIEW. INFORMATION SUBMITTED WAS A SINGLE PAGE
 WITH ONLY A SIMPSON HANGER TABLE. ENGINEER TO PROVIDE
 COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR THE
 SECOND FLOOR REPAIR FRAMING DETAILS, WALLS CONNECTIONS
 AND ROOF TO WALL CONNECTIONS AS REQUESTED BY THE
 BUILDING INSPECTOR ON 1/7/15 FIELD INSPECTION. SEC.
 107.2.1.3 OF CITY AMENDMENTS TO FBC.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR ALL THE SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED BY THE ENGINEER. PROVIDE PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR
 ENGINEER MAY LIST THE FLORIDA PRODUCT APPROVAL NUMBER
 NEXT TO THE SPECIFIED CONNECTOR.
  
 3- ALL DOCUMENTS PREPARED BY AN ENGINEER NEED TO HAVE
 THE SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-02-24 Cont ID  
Sent By tklarge Date 2015-02-24 Time 12:09 Rev Time 0.00
Received By tklarge Date 2015-02-04 Time 18:05 Sent To  
Notes
2015-02-04 18:05:24TO JG DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-27 Cont ID  
Sent By jgomez Date 2015-01-27 Time 12:41 Rev Time 0.00
Received By jgomez Date 2015-01-26 Time 17:27 Sent To  
Notes
2015-01-26 17:28:22REVISION SENT TO JULIO GOMEZ FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-02-24 Cont ID  
Sent By tklarge Date 2015-02-24 Time 11:47 Rev Time 0.00
Received By tklarge Date 2015-02-24 Time 11:47 Sent To  
Notes
***NONE***