Plan Review Details - Permit 15010841
Plan Review Stops For Permit 15010841
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-18 Cont ID  
Sent By jwitmer Date 2015-03-18 Time 07:19 Rev Time 0.00
Received By jwitmer Date 2015-03-18 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-02-19 Cont ID  
Sent By jwitmer Date 2015-02-19 Time 10:55 Rev Time 0.00
Received By jwitmer Date 2015-02-19 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-03-26 Cont ID  
Sent By rlecky Date 2015-03-26 Time 13:39 Rev Time 0.00
Received By rlecky Date 2015-03-26 Time 13:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-02-19 Cont ID  
Sent By rlecky Date 2015-02-19 Time 15:28 Rev Time 0.00
Received By rlecky Date 2015-02-19 Time 12:52 Sent To  
Notes
2015-02-19 15:57:0815010841
 401 CLEMATIS STREET
 EMERGENCY GAS GENERATOR
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 THE FEEDERS TO THE 1600 AMPERE DISCONNECT APPEAR TO BE
 UNDERSIZED. NEC 240.4(C)
  
 VERIFY THAT THE MAIN DISCONNECT FOR THE SEPERATELY
 DERIVED EMERGENCY SYSTEM IS LISTED AS SUITABLE FOR
 SERVICE EQUIPMENT. NEC 230.7
  
 PROVIDE A DETAIL WHICH INDICATES THE MINIMUM SIZE WITH
 DEMINSIONS FOR THE LARGE JUNCTION BOXES/WIREWAYS
 REQUIRED FOR THE NEW FEEDERS. NEC 314.28
  
 PROVIDE A DETAIL TO ANCHOR THE CONCRETE DUCT TO THE
 ROOF FOR THE WIND LOADING. FBC 1609
  
 VERIFY THE LOAD ON THE NEW GENERATOR DOES NOT EXCEED
 ITS CAPACITY. NEC 702.5
  
 THE ORANGE PHASE COLOR (SPECIFICATION IN SECTION 26 05
 53 ? 7) IS RESERVED FOR HIGH-LEG MARKING ON DELTA
 SYSTEMS. NEC 110.15
  
 PROVIDE A GROUNDING DETAIL FOR THE EXISTING GROUNDING
 ELECTRODE SYSTEM INTERCONNECTIONS TO THE NEW GENERATOR
 AND SWITCHES. NEC 250.30
  
 THE LINE DIAGRAM SHOWS A GENERATOR FEED TO A MANUAL
 TRANSFERE SWITCH FROM THE 1600 AMPERE EMERGENCY PANEL.
 IS THIS ACCURATE? NEC 210.15
  
 INDICATE ON PLANS THE TYPE, LOCATION AND MATERIAL OF
 ALL REQUIRED ELECTRICAL SAFETY SIGNS/PLAQUES FOR
 LOCATION OF DISCONNECTS, FLASH PROTECTION, STAND BY
 GROUNDING POINT, ETC. SIGN MUST BE LEGIBLE, AND
 SUITABLE FOR THE LOCATION AND ENVIRONMENT. NEC 110.22,
 110.9, 110.16, 702.8
  
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-01-27 Cont ID  
Sent By pleduc Date 2015-01-27 Time   Rev Time 0.00
Received By pleduc Date 2015-01-26 Time 16:29 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2015-02-20 Cont ID  
Sent By tklarge Date 2015-02-20 Time 11:53 Rev Time 0.00
Received By tklarge Date 2015-02-20 Time 11:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-26 Cont ID  
Sent By rlecky Date 2015-03-26 Time 13:39 Rev Time 0.00
Received By rlecky Date 2015-03-05 Time 14:44 Sent To  
Notes
2015-03-05 14:44:51C06
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-24 Cont ID  
Sent By tklarge Date 2015-02-24 Time 11:53 Rev Time 0.00
Received By tklarge Date 2015-01-23 Time   Sent To  
Notes
2015-01-24 08:08:29SENT TO C-03.

Review Stop Z ZONING
Rev No 2 Status P Date 2015-03-19 Cont ID  
Sent By aaponte Date 2015-03-19 Time 11:38 Rev Time 0.00
Received By aaponte Date 2015-03-19 Time 11:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-02-12 Cont ID  
Sent By aaponte Date 2015-02-12 Time 14:24 Rev Time 0.00
Received By aaponte Date 2015-02-12 Time 14:24 Sent To  
Notes
2015-02-02 15:51:022/2/15