Plan Review Details - Permit 15010385
Plan Review Stops For Permit 15010385
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-02-19 Cont ID  
Sent By dhayes Date 2015-02-19 Time 10:42 Rev Time 0.00
Received By dhayes Date 2015-02-19 Time 09:59 Sent To  
Notes
2015-02-19 10:42:311/15/2015
 PROJECT: 308 ARLINGTON RD. DOCK PEDESTAL
 PERMIT#: 15010385
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 2ND ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION.
  
 THE INFORMATION AND DOCUMENTATION REQUESTED TO BE
 PROVIDE TO THE INSPECTOR ON THE JOB FOR FINAL
 INSPECTION AND SUBMITTED TO DEVELOPMENT SERVICES FOR
 SCANNING INTO THE PERMIT FILE.
  
 1) PROVIDE THE OCPD AND WIRE SIZE FOR "FUTURE BOAT
 LIFT" ON THE PANEL SCHEDULE.
  
 2) PROVIDE MANUFACTURER DOCUMENTATION ON THE PROPOSED
 DOCK PEDESTAL TO INDICATE THE MINIMUM MANUFACTURER
 RECOMMENDED CIRCUITRY REQUIRED AND COMPLIANCE WITH NEC
 110.3(B) LISTING WITH A NRTL
  
 ) THERE IS NO INDICATION OF THE EXISTING # 6 WIRE OR
 THE NEW PEDESTAL. INDICATE THE LOCATION AND WIRING
 METHOD FOR THE EXISTING #6 WIRE. INDICATE THE LOCATION
 AND WIRING METHOD FOR THE NEW PEDESTAL.
  
 4) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. FL SS 471,
 668.001-668.006 FBC, WPB
 AMENDMENTS 107.2.1. PLANS ARE STILL NOT SIGNED OR BEAR
 THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-15 Cont ID  
Sent By dhayes Date 2015-01-15 Time 06:39 Rev Time 0.00
Received By dhayes Date 2015-01-15 Time 06:39 Sent To  
Notes
2015-01-15 07:15:091/15/2015
 PROJECT: 308 ARLINGTON RD. DOCK PEDISTAL
 PERMIT#: 15010385
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) PROVIDE A SITE PLAN FOR ADDITIONAL INFORMATION
 INDICATING THE SOURCE OF THE CIRCUIT THAT IS BEING
 EXTENDED TO THE PEDISTAL, THE LOCATION OF THE PEDISTAL
 RELATIVE TO THE EXISTING JUNCTION BOX AND THE ORIGINAL
 SOURCE. FBC 107.3.2
  
 2) PROVIDE ADDITIONAL INFORMATION RELATING TO THE
 CIRCUIT IN THE EXISTING JUNCTION BOX. IS IT AN EXISTING
 CIRCUIT THAT HAS BEEN ABANDONED AND NO LONGER HAS ANY
 LOAD CONNECTED TO IT? OR IS THE PROPOSED EXTENDED
 CIRCUIT FOR THE NEW DOCK PEDISTAL PROPOSED TO BE
 CONNECTED AN EXISTING LIVE LOAD?
  
 3) PROVIDE MANUFACTURER DOCUMENTATION ON THE PROPOSED
 DOCK PEDISTAL TO INDICATE THE MINIMUM MANUFACTURER
 RECOMENDED CIRCUITRY REQUIRED AND COMPLIANCE WITH NEC
 110.3(B) LISTING WITH A NRTL
  
 4) PROVIDE A LOAD CALCULATION INDICATING THE
 AVIALABILITY OF THE REQUIRED AMPACITY FOR THE NEW DOCK
 POWER PEDISTAL. NEC 220.14(C)
  
 5) .PROVIDE A PANEL SCHEDULE TO INDICATE THE SOURCE
 BREAKER. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL
 BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND
 SPECIFIC PURPOSE OR USE. NEC 408.4
  
 6) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. FL SS 471,
 668.001-668.006 FBC, WPB AMENDMENTS 107.2.1
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-02-19 Cont ID  
Sent By dhayes Date 2015-02-19 Time 10:42 Rev Time 0.00
Received By dhayes Date 2015-02-17 Time 09:03 Sent To  
Notes
2015-02-19 09:05:32TO DHAYES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-15 Cont ID  
Sent By dhayes Date 2015-01-15 Time 06:41 Rev Time 0.00
Received By dhayes Date 2015-01-14 Time 06:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy