Plan Review Details - Permit 15010206
Plan Review Stops For Permit 15010206 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-09 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-09 |
Time |
17:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-03-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-03-04 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-03-04 |
Time |
16:44 |
Sent To |
|
|
Notes |
2015-03-04 16:46:15 | RESIDENTIAL (R2) AWNINGS SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS | | INSTRUCTIONS SHOWING HOW THE FABRIC COVERED STRUCTURE | | IS DESIGNED FOR A QUICK REMOVAL OR BREAKAWAY ( A SERIES | | OF CLEAR PHOTOGRAPHS SHOWING THE DESIGN AND THE REMOVAL | | PROCESS IS ACCEPTABLE ALSO). SEC. 3105.4.2.1 OF 2010 | | FBC. (REPEAT COMMENT). | | | | 2- CLARIFY/REVISE GENERAL NOTE #2 OF DRAWING NUMBER | | 150122: REVISED GENERAL NOTE #2 STATES THAT "THE PERMIT | | HOLDER" SHOULD NOTIFY THE OWNER TO REMOVE THE AWNING | | COVER WHEN THE WINDS REACH 75 MPH. IF THIS IS THE | | INTENTION, THEN PROVIDE SIGNED LETTER FROM THE PERMIT | | HOLDER STATING HE/SHE WILL NOTIFY THE OWNER. SEC. | | 107.2.1 CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-01-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-01-16 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-01-16 |
Time |
13:16 |
Sent To |
|
|
Notes |
2015-01-16 13:16:44 | RESIDENTIAL (R2) AWNING BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- ENGINEER TO PROVIDE ORIGINAL SEAL AND SIGNATURE ON | | PLANS AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE. | | | | 2- ENGINEER TO SPECIFY ALL DESIGN CRITERIA INCLUDING | | AWNING LOCATION ON THE BUILDING (HEIGHT) AND THE | | EXPOSURE CATEGORY AS REQUIRED BY SEC. 3105.4 OF 2010 | | FBC-BUILDING. | | | | 3- AWNINGS TO BE APPROVED BY THE DESIGNER OF RECORD. | | SEC. 107.3.4.2 OF CITY AMENDMENTS TO FBC. | | | | 4- ARCHITECTURAL DRAWINGS SUBMITTED NEED TO BE SIGNED | | AND SEALED AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE. | | (NOTE: DRAWING MAY NOT BE SIGNED AND SEALED IF THE | | ARCHITECT STAMPS THE DRAWING WITH THE REVIEW STAMP | | REQUIRED ON ITEM #3 ABOVE). | | | | 5- A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS | | SHOWING HOW THE FABRIC COVERED STRUCTURE IS DESIGNED | | FOR A QUICK REMOVAL OR BREAKAWAY ( A SERIES OF CLEAR | | PHOTOGRAPHS SHOWING THE DESIGN AND THE REMOVAL PROCESS | | IS ACCEPTABLE ALSO). SEC. 3105.4.2.1 OF 2010 FBC. | | | | B) PROVIDE LETTER SIGNED BY THE BUILDING OWNER STATING | | THAT THE FABRIC WILL BE REMOVED IN THE EVENT OF 75 MPH | | WINDS. SEC. 3105.4.2.1 FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-01-16 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-01-16 |
Time |
13:16 |
Sent To |
|
|
Notes |
2015-01-09 08:04:16 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-02-12 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-02-12 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-02-12 |
Time |
15:48 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-01-16 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-01-16 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-01-16 |
Time |
16:32 |
Sent To |
B |
|
Notes |
|
|
|