Plan Review Details - Permit 14120909
Plan Review Stops For Permit 14120909 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-29 |
Time |
18:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-29 |
Time |
18:02 |
Sent To |
|
|
Notes |
2015-07-29 18:02:58 | CHANGED ADDRESS TO CORRECT PARCEL | | |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
N |
Date |
2018-01-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-09 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-09 |
Time |
16:01 |
Sent To |
|
|
Notes |
2018-01-09 16:02:09 | EXEMPT FROM AIPP ORDINANCE PER S.WELTER (VIA EMAIL | | 1/9/18) | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2016-02-16 |
Time |
|
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2016-02-11 |
Time |
10:35 |
Sent To |
|
|
Notes |
2016-02-16 11:03:44 | REVIEWED THE UNI-SPAN PARTIAL SHORING PLANS FOR THE 2ND | | LEVEL DECK (POUR #1) SHEETS S-1, S-2,S-3, AND LEVELS | | 3-8 (GRIDLINES #3 THRU #16) FROM LINES H.2 TO R-LINE, | | SHEETS S-4 AND S-5. | | | | | | 1) REQUIRE THE SUBMITTAL OF THE SHORING DESIGN | | CALCULATIONS PURSUANT TO THE FBC, SECTION 107.1/1603.1. | | | | 2) PROVIDE DETAILS/CALCULATIONS FOR GUARD RAIL SYSTEM | | PER THE FBC, SECTION 1607.8. | | | | 3) PLEASE SUBMIT RE-SHORING PLANS FOR REVIEW AND ENSURE | | THAT THE SAME IS REVIEWED BY THE ENGINEER OF RECORD. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-08-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-17 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-06 |
Time |
08:36 |
Sent To |
|
|
Notes |
2015-08-10 07:21:46 | 2010 FLORIDA BUILDING CODE | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | REVISION REQUIRED PRIOR TO COMMENCEMENT | | | | ****PROVISOS**** | | ISSUED AT CONTRACTOR'S RISK | | THE FOLLOWING ITEMS ARE PROVISO ITEMS, REVISION | | REQUIRED PRIOR TO FIRST INSPECTION | | ITEMS ABOVE ARE TO BE DONE PRIOR TO PERMIT ISSUANCE | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 2010 FLORIDA BUILDING CODE | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | THE FOLLOWING COMMENTS ARE TO BE ADDRESSED IF PLANS ARE | | RESUBMITTED FOR OTHER TRADES. IF PLANS ARE NOT | | RESUBMITTED, THE FOLLOWING ITEMS WILL BE PROVISO ITEMS, | | REVISION REQUIRED PRIOR TO COMMENCEMENT. | | | | PLEASE BE ADVISED THAT COMMENTS HAVE BEEN REARRANGED | | AND RENUMBERED FOR CLARITY. COMMENTS WHICH ARE TO BE | | ADDRESSED AT THIS TIME (AS OTHER TRADES FAILED AND A | | RESUBMITTAL IS REQUIRED) ARE BELOW. THE ITEMS WHICH ARE | | TO BE ADDRESSED AT A FUTURE DATE, OR ARE INFORMATIONAL | | ONLY, ARE NOW ALL AT THE END OF THE COMMENT LIST. | | | | 1. ARCHITECT?S RESPONSE INCLUDED BUILDING REVIEWS 1 AND | | 2. IF RESUBMITTING, ONLY CURRENT ITEMS ARE TO BE | | ADDRESSED. | | | | 2. FBC 107, AN OVERALL INDEX WAS PROVIDED (SHEET G000C) | | BUT THE INDEX IS NOT IN THE SAME ORDER AS THE | | PROJECTDOX FILES AND MANY SHEETS ARE STILL OUT OF | | ORDER. THIS HAS RESULTED IN ADDITIONAL PLAN REVIEW TIME | | FOR ALL REVIEWERS TO ATTEMPT TO LOCATE PAGES AND SERIES | | OF PLANS WITHIN THE FILE. A REVIEW OF PLAN ORDER WILL | | BE DONE PRIOR TO THE NEXT PLAN REVIEW. | | | | SOME ITEMS MAY HAVE NOT BEEN REVIEWED DUE TO THIS | | ISSUE. SOME OF THE PROJECTDOX ISSUES ARE: | | | | PHASE ONE/VOLUMEN ONE, EVERYTHING AFTER A625 (INCLUDING | | A626-644, INTERIORS, FOOD SERVICE) IS MISSING (FILES DO | | NOT FOLLOW SHEET A625 AS INDEX STATES, BUT ARE | | SCATTERED THROUGHOUT THE PLAN). THERE ARE A TOTAL OF AT | | LEAST 17 SHEETS WHICH ARE OUT OF ORDER. REPEAT COMMENT. | | | | IN101A BELONGS IN PHASE I, IS OUT OF ORDER AND IN PHASE | | 2. THIS COMMENT APPLIES TO ALL OF THE IN SHEETS (OUT OF | | ORDER, PAGES ARE SCATTERED THROUGHOUT THE PLAN). REPEAT | | COMMENT. | | | | THE ORDER OF THE PHASE / VOLUMEN IS NOT CONSISTENT WITH | | THE ORDERING OF THE PHASE / VOLUMEN IN THE PROJECTDOX | | FILE | | | | PHASE 2 IRRIGATION SHEETS ARE NOT INCLUDED ON EITHER | | INDEX (G000C OR PHASE TWO VOLUMEN TWO INDEX) | | | | 2110 - G000B DOESN'T INCLUDE FS (FOOD SERVICE) SHEETS, | | BUT THERE ARE FS SHEETS WHICH FOLLOW THE T (TECHNOLOGY) | | SHEETS. FS SHEETS ARE SHOWN ON G000C, BUT NOT IN THE | | ORDER SHOWN. | | | | REGARDING NAMING OF SHEETS, PAGES HAVE BEEN DIFFICULT | | TO LOCATE DUE TO INCONSISTENT INDEX AND NAMING | | CONVENTION WHICH IS NOT TYPICAL. SP WAS USED FOR SITE | | POOL, BUT IS USUALLY SITE PLAN. FS WAS USED FOR FOOD | | SERVICE, BUT THIS NAME IS USUALLY ASSIGNED TO FIRE | | SPRINKLER PAGES. K IS THE LETTER TYPICALLY USED FOR | | KITCHEN EQUIPMENT PLANS. OTHER REVIEWERS ARE STILL | | UNABLE TO LOCATE PAGES WHICH REQUIRE REVIEW. A DETAILED | | EXPLANATION OF PLAN ORDER ISSUES IS AVAILABLE VIA EMAIL | | UPON REQUEST. | | | | SEE PREVIOUS LIST REGARDING THE ORDER OF THE SERIES | | WITHIN THE PROJECTDOX FILE. THIS WAS NOT FIXED FOR THIS | | SUBMITTAL. | | | | ARCHITECT PROVIDED A RESPONSE NARRATIVE FOR AN | | EXPLANATION OF THE FILE ORDER. THIS IS NOT CONSISTENT | | WITH THE NAMING CONVENTION USED FOR THE FILES WHICH | | WERE UPLOADED, SO THE NARRATIVE IS NOT CONSISTENT WITH | | THE PROJECTDOX DOCUMENT. IN A 602 PAGE PLAN, IT IS VERY | | TIME CONSUMING TO SPECTULATE AS TO LOCATION OF | | INFORMATION. | | | | 3. APPENDIX C INCLUDES INFORMATION NOT INCLUDED IN THE | | SUMMARY PAGE PREPARED BY ARCHITECT. PER ARCHITECT?S | | COVER LETTER FOR THE APPENDIX DOCUMENT, APPENDIX C | | SHOULD INCLUDE ONLY FIRESTOP SYSTEMS AND DOOR HARDWARE | | INFORMATION. | | | | SOME PAGES INCLUDE INFORMATION REVIEWED BY OTHER TRADES | | (ELECTRICAL WIRING SPECS, COMMERCIAL KITCHEN EQUIPMENT | | SPECS, ETC.). | | | | THE SPEC BOOK SHEETS SUBMITTED HAVE NOT BEEN REVIEWED. | | SPEC BOOKS SHOULD NOT BE A PART OF THE PERMIT FILE AS | | THE PLANS ARE TO SHOW CODE COMPLIANCE. REMOVE THE SPEC | | SHEETS AND ALL OTHER SHEETS NOT INCLUDED ON THE | | APPENDIX SUMMARY FROM THE FILE. THEY SHOULD BE UPLOADED | | AS A SEPARATE FILE. | | | | IT WOULD HELPFUL IF THE COVER PAGE SUMMARY (WHICH | | SERVES AS AN INDEX) WOULD INCLUDE PAGE NUMBERS. THE | | DOCUMENT IS 191 PAGES. ANY LARGE DOCUMENT SHOULD BE | | PAGINATED, FBC 107. OR, SPLIT THE DOCUMENT INTO SEVERAL | | DOCUMENT. | | | | 4. A101 DOES NOT MATCH THE LIFE SAFETY PLAN AND OTHER | | SHEETS, PLEASE CORRELATE. IT IS DIFFICULT TO PERFORM A | | LIFE SAFETY REVIEW WITH THE MULTIPLE GRAPHICS ON THE | | LIFE SAFETY PAGE, OVERALL FLOOR PLAN WHICH IS CLEAN IS | | AN OLD VERSION, AND THE ENLARGED FLOOR PLAN HAS | | CONSTRUCTION DETAILS (WAS NOT INTENDED TO USE FOR LIFE | | SAFETY). THE GRAPHICS ON THE LIFE SAFETY PLAN OBSCURES | | WALLS AND DOORS. SHEET A101 IS REQUIRED FOR A COMPLETE | | LIFE SAFETY REVIEW. | | | | 5. G101 HAS A NOTE, TRAVEL DISTANCE TO GATE 48FT 10IN, | | APPEARS TO LEAD TO A DOOR, NOT A GATE, PLEASE REVISE. | | THIS IS THE SAME EXIT ACCESS WHICH GRAPHICALLY DEPICTS | | A WALL BLOCKING MEANS OF EGRESS, FBC 107. | | | | 6. DINING SHOW A DOUBLE DOOR OPENING INTO POOL AREA | | WITH TRAVEL DISTANCE TO GATE 107FT 3IN, BUT NO EXIT | | SIGN. EXIT STRATEGY NOT CLEAR. | | | | 7. FBC 1005.1, THE LOSS OF ONE MEANS OF EGRESS SHALL | | NOT REDUCE THE CAPACITY TO LESS THAN 50 PERCENT, SEE | | POOL AREA. ONE EXIT SIGN IS ADJACENT TO TWO GATES | | (DOUBLE AND SINGLE), OCCUPANT LOADS LISTED FOR BOTH, AS | | WELL AS OCCUPANT LOAD STATED FOR THE EXIT TO THE SOUTH, | | NO EXIT SIGNS FROM BUILDING TO POOL AREA, NOT CLEAR | | WHICH 452 OCCUPANTS ARE EXITING THROUGH THIS AREA (59, | | 117, 276 LABELED FOR POOL GATES). | | | | 8. OK OR MOVED TO END OF COMMENT LIST (INFORMATIONAL OR | | FUTURE PROVISO ITEMS, NOT REQUIRED TO BE ADDRESSED WITH | | THE REVISION) | | | | 9. G101, CORRIDOR 187 IS NOT A RATED CORRIDOR BUT | | SERVES THE RESIDENTIAL UNITS AS THERE IS AN EXIT SIGN | | FROM CORRIDOR 188 TO CORRIDOR 187, FBC TABLE 1018.1. | | THERE IS A NOTE WHICH STATES THAT TRAVEL DISTANCE IS | | 134FT, BUT IT IS NOT CLEAR WHERE THIS IS APPLICABLE. | | | | SEE OTHER COMMENT REGARDING EXIT ENCLOSURE DEFINITION; | | REVISE PLAN TO CLARIFY MEANS OF EGRESS COMPONENTS AND | | EXIT STRATEGY. | | | | 10. A101A AND G101, 47 FIXED SEATS SHOWN INCLUDING ONE | | COMPANION SEAT (TWO ARE REQUIRED BUT CAN BE MOVABLE IF | | COMPARABLE TO FIXED SEATING), TWO WHEELCHAIR SPACES | | APPEAR TO BE SHOWN (NOT MARKED, BUT RECTANGLES ARE | | SHOWN) BUT AN OCCUPANT LOAD OF 46 STATED AND NO | | OCCUPANT LOAD STATED FOR THE THEATER VESTIBULE. PLEASE | | CLARIFY THE MATH AND OCCUPANT LOAD. ALSO INCORPORATE A | | STATEMENT THAT ANY STAFF MEMBERS ENTERING THIS ROOM | | WILL BE USING ONE OF THE SEATS OR ADD A REASONABLE | | NUMBER OF STAFF MEMBERS TO THE OCCUPANT LOAD. | | | | REVISE PLAN TO LABEL THE TWO WHEELCHAIR SPACES AS SUCH. | | | | 11. PROVISO, G101 AND A213, THE DOORS FOR THE MULTI | | PURPOSE ROOM INCLUDE SIDELIGHTS WHICH APPEAR TO BE | | IDENTICAL TO THE DOORS BUT DO NOT OPERATE. SEE FBC | | 1008.1, REVISE PLAN TO SHOW HOW THE DOORS WILL BE | | EASILY DISTINGUISHABLE FROM THE INOPERABLE SIDELITES. | | | | SIGNAGE IS NOT ACCEPTABLE DUE TO THE LARGE NUMBER OF | | OCCUPANTS ATTEMPTING TO EXIT. ALSO SIGNAGE WOULD BE | | CONFUSING; SIGN STATES THIS IS NOT AN EXIT, BUT IT IS | | AN EXIT; UNLESS THE SIGN IS POSTED ON THE SIDELITE, | | SIGNAGE IS NOT CLEAR AS TO WHAT IS NOT AN EXIT. | | | | THIS ISSUE WILL BE A PROVISO ITEM. THE SIDELITES ARE | | GRAPHICALLY SHOWN AS IDENTICAL TO THE DOORS. | | | | THIS APPLIES TO BOTH DOORS 126 AND 124 (AND ANY OTHER | | DOORS AS APPLICABLE). | | | | 12. FROM PREVIOUS LISTS, G101, AEROBICS 146 AND FITNESS | | 143 APPEAR TO HAVE AN OCCUPANT LOAD OVER 50, BUT SECOND | | EXIT ACCESS NOT CLEAR. AEROBICS ROOM HAS TWO DOORS BUT | | BOTH LEAD TO SAME CORRIDOR (COMMON PATH). FITNESS ROOM | | HAS ONLY ONE EXIT ACCESS. TWO MEANS OF EGRESS REQUIRED | | FROM SPACES WITH AN OCCUPANT LOAD OVER 50, TWO EXITS | | REQUIRED FOR THE AREA. | | | | 2ND REVIEW, COMMENT NOT ADDRESSED. ARCHITECT RESPONSE | | IS THAT THE ROOMS INDIVIDUALLY HAVE AN OCCUPANT LOAD | | LESS THAN 50. | | | | AEROBICS AND FITNESS ROOMS EACH SEPARATELY HAVE AN | | OCCUPANT LOAD LESS THAN 50 BUT TOGETHER HAVE AN | | OCCUPANT LOAD OVER 50 WITH THE PARTITION OPEN. TO TREAT | | EACH AREA SEPARATELY, REPLACE THE MOVABLE PARTITION | | WITH A WALL. OCCUPANCY CLASSIFICATION IS STATED AS | | BUSINESS. THIS SHOULD BE ASSEMBLY, SEE DEFINITION. | | REGARDLESS OF OCCUPANCY CLASSIFICATION, THE DOORS ARE | | TO SWING IN THE DIRECTION OF TRAVEL (146 AND 146A), | | 1008.1.2 AS OCCUPANT LOAD EXCEEDS 50 WITH THE PARTITION | | OPEN. | | | | TRAVEL DISTANCE IS MEASURED TO THE GALLERY WHICH IS | | CALLED AN EXIT ENCLOSURE. SEE OTHER COMMENTS REGARDING | | THE DEFINITION OF EXIT ENCLOSURE. NOTE THAT AS | | DESIGNED, ALL OCCPANTS OF THIS AREA ARE FORCED TO GO | | THROUGH THE GALLERY WHICH IS OPEN TO TWO ELEVATORS. | | | | CONSIDER THE SCENARIO THAT SHOULD THERE BE AN ISSUE | | (FIRE OR SMOKE) IN THE ELEVATOR SHAFT, OCCUPANTS FOR | | THIS AREA ARE FORCED TO GO THROUGH A SMOKE FILLED EXIT | | ENCLOSURE. RATIONALE OF INCLUDING TWO ELEVATORS, TOILET | | ROOMS, LOW VOLTAGE SERVER ROOM, HOUSEKEEPING ROOM, OPEN | | LIVING ROOM LIBRARY, WORK ROOM IN AN ?EXIT ENCLOSURE? | | IS NOT CLEAR. | | | | SEE ALSO IBC CODE AND COMMENTARY 2009 (THE BASE CODE | | FOR FBC 2010), PAGE 7-62 (SECTION 708.14.1) WHERE | | ELEVATOR LOBBIES AND EXCEPTIONS ARE DISCUSSED AT | | LENGTH, WHICH SPECIFICALLY STATES: | | | | OF COURSE, THE ELEVATOR HOISTWAY DOORS CAN NEVER OPEN | | INTO AN EXIT ENCLOSURE. | | | | REVISE PLAN SO THAT THE EXIT ENCLOSURE INCLUDES ONLY | | ITEMS WHICH DO NOT POSE A HAZARD TO THE EXIT ENCLOSURE. | | THE LIVING ROOM WILL CONTAIN FURNITURE AND OTHER | | COMBUSTIBLES (HAZARD). THE ELEVATORS THEMSELVES POSE A | | HAZARD (EVEN WITH PRESSURIZATION). THE OTHER ROOMS | | CURRENTLY SHOWN WITHIN THE EXIT ENCLOSURE SHOULD ALSO | | BE SEPARATED FROM THE EXIT ENCLOSURE. | | | | REVISE PLAN SO THAT EXIT STRATEGY ADDRESSES THESE | | CONCERNS. | | | | 13. AN ADDITIONAL DOOR WAS PROVIDED TO ADDRESS THE DEAD | | END BUT SEE OTHER COMMENTS REGARDING TWO EXITS REQUIRED | | AND USE OF THE GALLERY AS AN EXIT ENCLOSURE. PRIOR TO | | RESUBMITTAL, ENSURE THAT NO NEW DEAD ENDS ARE CREATED. | | | | 14. G101, REVISE PLAN TO INCLUDE OCCUPANT LOAD AND AREA | | FOR THE FITNESS ROOM AND AEROBICS ROOM (SEPARATELY AS | | THE LARGER AREA CAN BE COMBINED TO TWO SMALLER AREAS). | | AS IT APPEARS THAT THE AEROBICS AND FITNESS AREA | | OCCUPANT LOAD WILL BE OVER 50, DOORS ARE TO SWING IN | | THE DIRECTION OF TRAVEL, FBC 1008.1.2. | | | | NOT ADDRESSED. CHANGE DOOR SWING OR ADD A WALL AT THE | | LOCATION OF THE FOLDING PARTITION. OCCUPANT FOR THE | | ROOM WITH THE PARTITION IS OVER 50 (PER BUILDING | | OFFICIAL). | | | | 15. THE AEROBICS AND FITNESS AREA OCCUPANT LOAD IS OVER | | 50, FIRE EXIT HARDWARE OR PANIC HARDWARE REQUIRED FOR | | THOSE DOORS AND ALL OTHER DOORS IN THE MEANS OF EGRESS, | | FBC 1008.1.10, 1004.9. | | | | NOT ADDRESED. | | | | 16. EGRESS GATE IS REQUIRED TO HAVE EITHER FIRE EXIT | | HARDWARE OR PANIC HARDWARE, FBC 1008.1.10, 1008.2. | | REVISE PLAN TO INCLUDE THE REQUIREMENT OR DETAIL. | | | | RESPONSE LETTER STATES TO SEE AS102. INDEX SHOWS THE AS | | SERIES BEFORE A SHEETS. UNABLE TO LOCATE SHEET (NOT IN | | THIS LOCATION). COMMENT NOT ADDRESSED. | | | | 17. DOOR SCHEDULE HAS A COLUMN FOR ?ELECTRIC? BUT THAT | | COLUMN IS BLANK. IT APPEARS THAT THIS SHOULD BE | | APPLICABLE FOR SLIDING DOORS IN THE REQUIRED MEANS OF | | EGRESS AND EXIT. EXIT DOOR 122 (DOOR TYPE G1) SHOULD | | ALSO COMPLY WITH FBC 1008.1.4.2, 1008.1.4.3. | | | | 18. A601 AND G101, DOORS IN FIRE BARRIERS REQUIRE A 45 | | MINUTE FIRE RATING, FBC TABLE 715.4. IT IS NOT CLEAR | | WHICH DOORS ARE BEING CONSIDERED IN A CORRIDOR RATHER | | THAN AN OCCUPANCY SEPARATION. SEE DOORS 173C, 182, 172, | | 183. | | | | DOOR 173C IS A 20 MINUTE DOOR, BUT THE CORRIDOR 184 | | RATING IS NOT CONTINUOUS AS IT APPEARS TO TRANSITION | | INTO THE GALLERY. USE OF CORRIDORS, INCIDENTAL AND | | ACCESSORY USES FBC 508 ARE NOT ENTIRELY CLEAR. IF ANY 1 | | HOUR RATINGS ON THE PLAN ARE REMOVED WHEN RESUBMITTING, | | PLEASE ALSO NOTE ALSO SMOKE AND PROTECTION REQUIREMENT | | IN 508.2.5.2. | | | | 19. SEE G102 AND OTHER FLOORS, THERE IS AN UNIDENTIFIED | | 1 HOUR RECTANGLE ADJACENT TO THE ELEVATOR 2-2. THIS | | AREA IS NOT IDENTIFIED ON A102, A102A. FBC 107, USE OF | | THIS SPACE AND REQUIRED FIRE RESISTANCE RATING NOT | | CLEAR. | | | | 20. THE MCKEON DOOR SPECIFIED DOES NOT MEET THE MINIMUM | | REQUIREMENTS OF FBC 715.4. THE DOOR SPEC SHEET STATES | | THAT IT MEETS UL 10B FOR 20 MINUTES. SEE G101, 45 | | MINUTE AND 60 MINUTE ARE REQUIRED. | | | | 21. PLANS IN MANY LOCATIONS USE THE LANGUAGE "UNDER | | SEPARATE PERMIT" (FOR INSTANCE, SHEET 036 - S6.2). IF | | ALL WORK TO BE INCLUDED IN THIS PERMIT, REVISE | | LANGUAGE. | | | | PLANS STILL REFER TO SEPARATE PERMIT FOR PHASE I AND | | PHASE II. PHASE ONE PLANS REFER TO PHASE TWO AS A | | SEPARATE PERMIT. PHASE TWO REFERS TO PHASE ONE AS A | | SEPARATE PERMIT. SEE OTHER COMMENT REGARDING | | CONSIDERING PUTTING THE TWO PHASES INTO TWO SEPARATE | | PERMITS. IF ALL WORK TO REMAIN UNDER ONE PERMIT, PLEASE | | REVISE LANGUAGE AS IT IS CONFUSING. SEE FBC 107, PLANS | | SHOULD BE CLEAR AS TO SCOPE AND NATURE OF WORK. | | | | 22. INCORPORATE FIRE RATING REQUIREMENTS AND DETAILS | | FOR THE FLOOR, STRUCTURAL ELEMENTS FBC TABLE 601. | | | | NOT ADDRESSED. DETAILS SHOWING THE TESTED ASSEMBLY OR | | CALCULATED FIRE RESISTANCE REQUIRED, SEE FBC 703. A | | STATEMENT IN A RESPONSE LETTER THAT EVERYTHING COMPLIES | | IS NOT ADEQUATE TO DEMONSTRATE CODE COMPLIANCE FOR THIS | | HIGH RISE BUILDING. | | | | NOTE THAT THE LIFE SAFETY PLAN, WHICH SHOWS OTHER FIRE | | RESISTANCE RATINGS, IS LACKING INFORMATION REGARDING | | EXTERIOR WALLS AND STRUCTURAL FRAME. PROPOSED FIRE | | RATING FOR THE STRUCTURAL ELEMENTS IS NOT CLEAR. IT IS | | NOT CLEAR WHETHER FBC TABLE 601 OR 602 WILL DETERMINE | | THE EXTERIOR WALL RATINGS. | | | | NEW COMMENTS DUE TO NEW INFORMATION: | | | | 23. CLOUDS INDICATING CHANGES FROM REVISION 0 TO | | REVISION 4 HAVE BEEN REMOVED. FOUR VERSIONS OF G101 | | HAVE BEEN UPLOADED TO PROJECT DOX. ONE SET WAS NOT | | REVIEWED (VERSION 2) AND IT APPEARS THAT VERSION 3 HAS | | BEEN UPLOADED TWICE. | | | | PLEASE RETAIN ALL CLOUDS FOR CHANGES NOT REVIEWED | | (FUTURE REVISIONS). | | | | 24. G101, AREA SCHEDULE (GROSS BUILDING) IS LACKING THE | | TOTAL AND ALSO LACKS THIRD THROUGH SEVENTH FLOOR, FBC | | 107, FBC 107. | | | | 25. G101, AT 3 HOUR FIRE WALL, PLAN STATES THAT 1 HOUR | | FIRE PROTECTION IS REQUIRED (EXTENDED 4 FT FROM FIRE | | WALL). SEE FBC TABLE 601 AND 602; BASED ON OTHER MORE | | STRINGENT REQUIREMENTS, 1 HOUR DOES NOT APPEAR TO BE | | SUFFICIENT. BEARING WALLS ARE TO BE 3 HOURS. SEE OTHER | | COMMENT REGARDING FIRE RATING DETAILS. | | | | 26. A352, PT WOOD AND EXT PLYWOOD IS SHOWN. SEE FBC | | 603, 717.5, 718.3, IT APPEARS THAT THERE IS AN | | EXCESSIVE AMOUNT OF COMBUSTIBLE, NON FRT LUMBER | | INSTALLED AT 130 FT. EITHER REVISE TO NON COMBUSTIBLE | | MATERIALS OR PROVIDE RATIONALE OR EXCEPTION. | | | | 27. G101, ROOM TO THE NORTH OF AIR HANDLER ROOM 180 IS | | NOT LABELED. | | | | 28. G101, THE DINING ROOM EGRESS (SOUTH EAST CORNER OF | | DISPLAY KITCHEN DINING B) PATH TO WOUTH EXIT GOES | | THROUGH A WALL, SEE THE L SHAPE AREA BETWEEN NORTH | | WALLS OF OFFICE 163C AND DRY STORAGE 166. REVISE OR | | CLARIFY. | | | | 29. SP AND WF SHEETS, NEW POOL AND WALL FOUNTAIN PLANS | | WERE SUBMITTED. THEY HAVE NOT BEEN REVIEWED AT THIS | | TIME AND REQUIRE SEPARATE PERMITS. HOWEVER, IN TAKING A | | CURSORY GLANCE AT THE PLANS, IT APPEARS THAT THE POOL | | WAS DESIGNED TO FBC 2010 RESIDENTIAL DUE TO THE FBC | | 2010 RESIDENTIAL REFERENCES ON THE PLANS. | | | | 30. ENERGY CALCS WERE SUBMITTED. INCLUDED ON THE ENERGY | | CALCS IS A GAS HOT WATER BOILER, BETWEEN 300,000 AND | | 2.5 MILLION BTUS. SEE FBC 1015.3 REGARDING EXITING | | REQUIREMENTS FOR BOILER ROOMS. WHERE IS THIS BOILER | | LOCATED? IT IS NOT SHOWN ON THE LIFE SAFETY PLAN, FBC | | 107. REVISE OR CLARIFY. | | | | 31. REVISED SHEET G101 SHOWS TRAVEL DISTANCE AS 130FT | | FROM THE FITNESS LOUNGE TO THE EXIT ENCLOSURE. SEE THE | | DEFINITION OF CORRIDOR, FBC 1002, AN ENCLOSED EXIT | | ACCESS COMPONENT THAT DEFINES AND PROVIDES A PATH OF | | EGRESS TRAVEL TO AN EXIT. | | | | SEE ALSO DEFINITION OF EXIT ENCLOSURE, AN EXIT | | COMPONENT THAT IS SEPARATED FROM OTHER INTERIOR SPACES | | OF A BUILDING OR STRUCTURE BY FIRE RESISTANCE RATED | | CONSTRUCTION AND OPENING PROTECTIVES. MANY ROOMS ARE | | INCLUDED IN THE GALLERY (HOUSEKEEPING, LIVING ROOM, | | ELEVATOR LOBBIES, TOILET ROOMS, ETC.). DEFINITION | | STATES THAT AN EXIT ENCLOSURE IS TO BE SEPARATED FROM | | OTHER INTERIOR SPACES. | | | | THIS COMMENT ALSO APPLIES TO THE RESIDENTIAL AREA | | EXITING. RESIDENTIAL CORRIDOR TAKES THE OCCUPANT | | THROUGH THE 1 HOUR RATED CORRIDOR THROUGH THIS GALLERY | | AREA, NOW CALLED AN EXIT ENCLOSURE, BUT THE GALLERY AS | | SHOWN ON G101 DOES NOT MEET THE DEFINITION OF AN EXIT | | ENCLOSURE. AN EXIT ENCLOSURE IS TO BE SEPARATED FROM | | OTHER INTERIOR SPACES. ONCE AN OCCUPANT ENTERS THE | | EXIT, THE EXIT IS TO BE CONTINUOUS UNTIL THE EXIT | | DISCHARGE. | | | | 32. CHANGES TO THE PROPERTY LINE (REPLAT) REQUIRE THAT | | COMPLIANCE WITH FBC TABLE 705.8 (MAXIMUM AREA OF | | EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION | | DISTANCE) AND FBC TABLE 602 (FIRE RESISTANCE RATING | | REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE | | SEPARATION DISTANCE) BE SHOWN. A REVISION WILL BE | | REQUIRED PRIOR TO CERTIFICATE OF COMPLETION. | | | | 33. REVISE SHEET G001, REQUIRED FIRE RESISTIVE RATINGS. | | DISTANCE TO PROPERTY LINE IS FOR GREATER THAN 30FT | | SEPARATION. AS THERE IS A PROPERTY LINE BETWEEN THE TWO | | BUILDINGS, THIS IS NOT ACCURATE. DUE TO THE EXCEPTION | | FOR ONE STORY (1 HOUR REDUCTION FBC TABLE 601 FOOTNOTE | | A), DISTANCE TO PROPERTY LINE (FBC TABLE 602) APPEARS | | TO BE MORE RESTRICTIVE (2 HOUR REEQUIRED FROM 5 FEET TO | | UNDER 20 FEET). | | | | 34. THRESHOLD PLAN STATEMENT REQUIRED BY FS 553.79 TO | | BE CORRECTED ON STRUCTURAL DRAWINGS. EVIDENCE THAT THIS | | HAS BEEN CORRECTED IS TO BE SENT TO ME VIA EMAIL PRIOR | | TO PERMIT ISSUANCE. PLANS ARE TO BE SUBMITTED AS A | | REVISION PRIOR TO COMMENCEMENT IF PERMIT IS ISSUED THIS | | REVIEW CYCLE. IF PERMIT IS NOT ISSUED IN THIS REVIEW | | CYCLE, REVISED DRAWINGS TO BE RESUBMITTED. (EMAIL | | RECEIVED FROM STRUCTURAL ENGINEER ON 8/18/15) | | | | 35. AS ALL STRUCTURAL SHEETS ARE REQUIRED TO BE | | REVISED, SEE PREVIOUS LIST REGARDING THE ADDRESS ON THE | | PLAN AND REVISE. STRUCTURAL SHEETS STILL HAVE INCORRECT | | ADDRESS OF 4920 LORING DRIVE. | | | | 36. UNIT 1A, SHOW CLEAR FLOOR SPACE CENTERED ON SINK, | | SHEET A 401A. | | | | 37. AS 109, POOL BAR AREA, CLARIFY PURPOSE THIS AREA; | | IS THIS FOR STAFF ONLY (WORK AREA), OR FOR USE BY | | RESIDENTS AND THEIR GUESTS? THERE IS A STATEMENT ON THE | | PLAN WHICH STATES THAT AMENITY SPACES AND COMMON AREAS | | ARE ONLY USED BY RESIDENTS AND THEIR GUEST. THERE ARE | | OFFICES, SPA, LARGE RESTAURANT STYLE DINING AREA, BUT | | THE PLAN DOES NOT INDICATE WHICH AREAS ARE FOR USE BY | | EMPLOYEES. | | | | IT IS NOT CLEAR WHETHER ACCESSIBILITY OR FAIR HOUSING | | APPLIES. MORE INFORMATION REQUIRED; NO CLEAR FLOOR | | SPACE SHOWN FOR FIXTURES, SINK AND COUNTER ARE AT 40 | | INCHES. WILL FOOD OR DRINKS BE SOLD AT THIS LOCATION? | | SEE FBC 2010 ACCESSIBILITY 804, 902, 904, 606, CFR | | 100.205(C)(1). | | | | 38. BREAK ROOM APPEARS TO BE FOR EMPLOYEE USE. SINK TO | | COMPLY WITH FBC 2010 ACCESSIBILITY 606. | | | | 39. SEE PLUMBING COMMENTS REGARDING OTHER ACCESSIBILITY | | AND FAIR HOUSING AND REVISE PLAN TO SHOW APPLICABLE | | DIMENSIONS. | | | | 40. SEE FIRE REPEAT COMMENT REGARDING FBC 403.3.2, | | SHEET 402, FIRE PUMP SHALL BE SUPPLIED BY A MINIMUM OF | | TWO WATER MAINS LOCATED IN DIFFERENT STREETS. AS WITH | | THE STRUCTURAL SHEETS, REVISE AND PROVIDE EVIDENCE VIA | | EMAIL THAT THIS ITEM HAS BEEN ADDRESSED. | | ***************************** | | PROVISOS | | ISSUED AT CONTRACTOR'S RISK | | | | 1. AS PER OWNER?S AGREEMENT, A REPLAT WILL BE FILED | | WITHIN 45 DAYS OF PERMIT ISSUANCE. FINAL PLAT REQUIRED | | PRIOR TO C.O. A NEW SITE PLAN SHOWING DISTANCE TO THE | | NEW PROPERTY LINE TO BE SUBMITTED FOR REVIEW AS A | | REVISION. | | | | 2. ADVISORY ONLY, SEPARATE PERMITS (PLANS, APPLICATION, | | REVIEWS, AND FEES) REQUIRED FOR PARKING LOT, SIGNAGE, | | AWNINGS, FENCING, POOL, TRELLIS, SITE WALL, SEPARATE | | BUILDINGS (INCLUDING GENERATOR BUILDING), FBC 107. | | | | 3. THE FOLLOWING SHEETS HAVE BEEN VOIDED AND WERE NOT | | REVIEWED: SP101, SP102, SP103, SP104, SP105, SP106, | | WF101, WF102, AND WF103. SUBMIT THESE PAGES UNDER | | SEPARATE PERMIT APPLICATION. | | | | 4. ADVISORY ONLY, THE ART IN PUBLIC PLACES WAS SENT VIA | | EMAIL, CITY OF WEST PALM BEACH CODE OF ORDINANCES | | 78-123, 78-126. | | | | THIS PERMIT WILL BE ISSUED WITH THE PROVISO THAT, | | WITHIN 90 DAYS OF ISSUANCE, THE APPROVAL WILL BE | | PROVIDED. PLEASE SEND A COPY OF THE APPROVAL WHEN | | AVAILABLE VIA EMAIL TO [email protected] IN ORDER TO | | DOCUMENT THE PERMIT FILE. | | | | 5. ADVISORY ONLY, FS 553.79(7)(C) ALL SHORING AND | | RESHORING PROCEDURES, PLANS, AND DETAILS BE SUBMITTED | | TO THE ENFORCEMENT AGENCY FOR RECORDKEEPING. | | SHORING/RESHORE ENGINEERING TO BE SUBMITTED AT EACH | | LIFT. FAILURE TO SUBMIT SHORING/RESHORE PLANS TO THE | | BUILDING DIVISION FOR PLAN REVIEW AT THE TIME OF EACH | | LIFT MAY RESULT IN A STOP WORK ORDER. AS THIS ISSUE HAS | | BEEN PROBLEMATIC IN THE PAST, IT IS RECOMMENDED THAT A | | NOTE BE INCORPORATED INTO THE PLAN. | | | | 6. ADVISORY ONLY, PRODUCT APPROVALS REVIEWED BY | | DESIGNER OF RECORD ARE TO BE SUBMITTED FOR REVIEW PRIOR | | TO INSTALLATION, FBC 107, FBC 1609 (SUBMITTAL, NO FEE). | | COMPONENTS AND CLADDING TO COMPLY WITH WALL PRESSURES | | SHOWN ON SHEET S8.5: | | | | ZONE 4 + 52.0 / - 52.2 | | ZONE 5 + 52.0 / -95.7 | | | | FOR ROOF COVERING, SEE ROOF PLAN REVIEW STOP OR SHEET | | S8.5 FOR PRESSURES. | | | | 8. PROVISO, FBC 911.1.4, LAYOUT OF FIRE COMMAND CENTER | | AND ALL FEATURES REQUIRED BY 911.1.5 TO BE SUBMITTED | | AND APPROVED PRIOR TO INSTALLATION. | | | | 9. PROVISO, G101 AND A213, THE DOORS FOR THE MULTI | | PURPOSE ROOM INCLUDE SIDELIGHTS WHICH APPEAR TO BE | | IDENTICAL TO THE DOORS BUT DO NOT OPERATE. SEE FBC | | 1008.1, DOORS TO BE EASILY DISTINGUISHABLE FROM THE | | INOPERABLE SIDELITES. | | | | 10. PROVISO, THE FOLLOWING TEST REPORTS FOR THE | | FLOORING UNDERLAYMENT WILL BE REQUIRED PRIOR TO | | INSTALLATION (INFORMATIONAL NOTE: PER S2.4, S3.1 FLOOR | | SLABS ARE 8IN, SO STC AND IIC TESTS ON AN 8IN SLAB OR | | LESS ARE ACCEPTABLE): STC (FBC 1207.2), IIC (FBC | | 1207.3), ASTM E 84 (FBC 603.1). | | | | 11. PROVISO, FBC 2010 ACCESSIBILITY 703, SIGNS TO | | COMPLY WITH THIS SECTION. | | | | 12. PROVISO, DETAILS FOR UL ASSEMBLIES REFERENCED ON | | THE PLANS ARE TO BE SUBMITTED WITH OPTIONS NOTED PRIOR | | TO INSTALLATION. IF NOT PREPARED BY DESIGNER OF RECORD, | | SHOP DRAWING REVIEW REQUIRED PRIOR TO SUBMITTAL. | | | | AS THE EXTERIOR WALLS ARE FIRE RATED, DETAILS FOR | | STRUCTURE AND EXTERIOR WALLS REQUIRED PRIOR TO | | COMMENCEMENT. | | | | 13. PROVISO, REVISED PLANS TO INCLUDE TOTAL SQUARE FOOT | | AREA, PER FLOOR, PER OCCUPANCY CLASSIFICATION, TO | | INCLUDE BOTH PHASE I AND PHASE II, FBC 107, FBC 109. | | VALUE (ADJUSTED PER ICC TABLE AND COTLEUR & HEARING | | SITE PLAN) WILL BE CONFIRMED AND MAY BE INCREASED. | | ISSUED AT CONTRACTOR'S RISK. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
S. Hill |
Date |
2015-05-18 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-04 |
Time |
14:11 |
Sent To |
|
|
Notes |
2015-05-18 14:50:23 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 2010 FLORIDA BUILDING CODE | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1. FOR ALL THRESHOLD JOBS, FS 553.79(7)(D) ALL PLANS | | FOR THE BUILDING WHICH ARE REQUIRED TO BE SIGNED AND | | SEALED BY THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A | | STATEMENT THAT, TO THE BEST OF THE ARCHITECT?S OR | | ENGINEER?S KNOWLEDGE, THE PLANS AND SPECIFICATIONS | | COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND | | THE APPLICABLE FIRESAFETY STANDARDS AS DETERMINED BY | | THE LOCAL AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND | | CHAPTER 633. | | | | PLEASE INCORPORATE THIS STATEMENT INTO THE PLANS. IT IS | | TYPICAL FOR THIS STATEMENT TO BE ON EACH SHEET. IF | | DESIGNER OBJECTS TO INCLUDING THIS STATEMENT ON EACH | | SHEET AND WOULD LIKE THE STATEMENT ON ONE SHEET ONLY, | | PLEASE ADVISE AND THIS OPTION WILL BE INVESTIGATED WITH | | THE APPROPRIATE BOARD. | | | | 2. IT IS NOT CLEAR WHETHER THE NEW BUILDING WILL BE | | CONSIDERED AN ADDITION TO THE EXISTING BUILDING, ON THE | | SAME PARCEL, CONNECTED BY A WALKWAY, OR IF WILL BE | | TREATED AS A NEW BUILDING, SEPARATE PARCEL, OR NEW | | BUILDING, SAME PARCEL (WITH UNITY OF TITLE, SEE OTHER | | COMMENTS). | | | | IF THE TWO TOWERS ARE DESIGNED AS ONE BUILDING, | | DESIGNER TO REFERENCE FBC 2010 EXISTING BUILDING | | CHAPTER 10 (ADDITIONS) AS WELL AS METHOD OF COMPLIANCE | | FOR THE EXISTING BUILDING (SEE FBC 2010 EXISTING | | BUILDING 101.5). THIS IS REQUIRED IN ORDER TO ADDRESS | | ISSUES AS THEY ARISE EITHER IN THE FIELD OR IN PLAN. | | | | 3. CHIEF BUILDING INSPECTOR AGREES THAT, IF ALL PARTIES | | FOR THE TWO PROJECTS (DINING ROOM EXPANSION AND PHASE | | I, 14120908 AND 14120909) ARE THE SAME, ONE SET OF | | THRESHOLD DOCUMENTS (RESUMES, AGREEMENTS) IS | | ACCEPTABLE. IF THIS IS NOT ACCEPTABLE TO ANY OF THE | | PARTIES, PLEASE CONTACT ME TO DISCUSS. | | | | THRESHOLD DOCUMENTS REQUIRED: | | | | SPECIAL INSPECTOR AGREEMENT | | RESUME AND COPIES OF LICENSES FOR SPECIAL INSPECTOR AND | | ALL ON SITE INSPECTORS | | RESUME AND COPIES OF LICENSES FOR CONTRACTOR, JOB | | SUPERINTENDENT AND/OR PROJECT MANAGER | | | | 4. THE BUSINESS LICENSE NUMBER, NAME AND ADDRESS SHOWN | | ON THE PLAN (PERKINS EASTMAN, FS95000000559, | | PITTSBURGH, PA) ARE NOT CONSISTENT WITH DBPR RECORDS | | (PERKINS EASTMAN ARCHITECTS, D.P.C., INC, AA26000763, | | NEW YORK, NY). SINCE THE ADDRESS, NAME, AND LICENSE | | NUMBER ARE DIFFERENT FROM DBPR RECORDS, IT IS NOT | | POSSIBLE TO DETERMINE THE ARCHITECT (COMPANY) TAKING | | RESPONSIBILITY FOR THE DESIGN. | | | | SEE FS 481.219, CERTIFICATE OF AUTHORIZATION REQUIRED | | AND THE NUMBER IS TO BE ON ALL FINAL CONSTRUCTION | | DOCUMENTS. | | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/PRO/ARCH/STATUTES. | | HTML | | | | 5. PAPA RECORDS SHOW A PROPERTY LINE WHICH IS NOT SHOWN | | ON THE PLANS SUBMITTED. WILL THE TWO PROPERTIES REMAIN | | SEPARATE PARCELS, HAVE THEY ALREADY BEEN COMBINED WITH | | A UNITY OF TITLE, OR WILL THEY BE COMBINED WITH A UNITY | | OF TITLE? IF THEY ARE TO REMAIN SEPARATE PARCELS, SEE | | FBC TABLE 602, TABLE 705.8 AND REVISE PLAN TO SHOW | | COMPLIANCE (DISTANCE TO PROPERTY LINE, RATED WALLS AS | | APPLICABLE, PROTECTED OPENINGS IF PERMITTED). | | | | IT APPEARS THAT THE PROPERTY LINE BETWEEN 4920 LORING | | DRIVE AND 4850 LORING DRIVE DIVIDES THE NEW BUILDING | | KNOWN AS TRADITIONS II PHASE ONE. | | | | THE DISTANCE OF PROPOSED BUILDING TO THE ACTUAL | | PROPERTY LINE (AS PER PAPA, NOT SHOWN ON PLANS) IS | | UNCLEAR. | | | | IF YOU HAVE NOT ALREADY SUBMITTED APPLICATION FOR UNITY | | OF TITLE AND WISH TO DO SO, THE APPLICATION IS | | AVAILABLE ONLINE: | | | | HTTP://WPB.ORG/WP-CONTENT/UPLOADS/SITES/7/2012/05/2011- | | 11-14-16-09-54-APPLICATIONFORUNITYOFTITLE.PDF | | | | 6. THE ADDRESS ASSIGNED TO THIS BUILDING IS 4850 LORING | | DRIVE; PLEASE REVISE PLANS AS APPLICABLE. | | | | 7. FS553, AS PERMITS 14120908 AND 14120909 WERE | | INITIALLY FOUNDATION PERMITS, PLEASE PROVIDE NEW | | APPLICATIONS WITH THE NEW SCOPE OF WORK AND VALUE, | | SIGNED BY THE QUALIFIER AND THE OWNER. ALSO PLEASE NOTE | | THAT IT APPEARS THAT THE NEW BUILDING (TRADITIONS II | | PHASE ONE) IS LOCATED PRIMARILY ON A PARCEL WITH AN | | ADDRESS OF 4850 LORING DRIVE, LOCATED ON TRACT C, | | PARCEL ID 74-42-43-12-26-003-0000. | | | | 8. SEPARATE PERMITS (PLANS, APPLICATION, REVIEWS, AND | | FEES) REQUIRED FOR PARKING LOT, SIGNAGE, FENCING, POOL, | | TRELLIS, FBC 107. | | | | 9. ADVISORY ONLY, THE ART IN PUBLIC PLACES WAS SENT VIA | | EMAIL, CITY OF WEST PALM BEACH CODE OF ORDINANCES | | 78-123, 78-126. | | | | THIS PERMIT WILL BE ISSUED WITH THE PROVISO THAT, | | WITHIN 90 DAYS OF ISSUANCE, THE APPROVAL WILL BE | | PROVIDED. PLEASE SEND A COPY OF THE APPROVAL WHEN | | AVAILABLE VIA EMAIL TO [email protected] IN ORDER TO | | DOCUMENT THE PERMIT FILE. | | | | 10. ADVISORY ONLY, FS 553.79(7)(C) ALL SHORING AND | | RESHORING PROCEDURES, PLANS, AND DETAILS BE SUBMITTED | | TO THE ENFORCEMENT AGENCY FOR RECORDKEEPING. | | SHORING/RESHORE ENGINEERING TO BE SUBMITTED AT EACH | | LIFT. FAILURE TO SUBMIT SHORING/RESHORE PLANS TO THE | | BUILDING DIVISION FOR PLAN REVIEW AT THE TIME OF EACH | | LIFT MAY RESULT IN A STOP WORK ORDER. AS THIS ISSUE HAS | | BEEN PROBLEMATIC IN THE PAST, IT IS RECOMMENDED THAT A | | NOTE BE INCORPORATED INTO THE PLAN. | | | | 11. ADVISORY ONLY, PRODUCT APPROVALS REVIEWED BY | | DESIGNER OF RECORD ARE TO BE SUBMITTED FOR REVIEW PRIOR | | TO INSTALLATION IF NOT SUBMITTED AT THIS TIME, FBC 107, | | FBC 1609 (SUBMITTAL, NO FEE). | | | | 12. ADVISORY ONLY, POOL DETAILS NOT REVIEWED AT THIS | | TIME. POOL WILL BE REVIEWED UNDER A SEPARATE PERMIT, | | FBC 107. | | | | 13. FOR TRACKING PURPOSES, A SEPARATE PERMIT IS | | REQUIRED FOR THE DETACHED GENERATOR BUILDING, FBC 107. | | | | 14. ADVISORY ONLY, AT THIS TIME, THE "R" (ROOFING) STOP | | HAS A REVIEW STATUS OF "N". PRODUCT APPROVALS AND | | ENGINEERING, IF APPLICABLE, WILL BE REQUIRED AT TIME OF | | ROOF SUB PERMIT APPLICATION IF NOT SUBMITTED DURING THE | | PLAN REVIEW PROCESS FOR THE ADDITION. | | | | 15. ADVISORY ONLY; PARKING LOT STRIPING, AWNINGS, SIGNS | | AND OTHER INDEPENDENT STRUCTURAL ELEMENTS REQUIRE | | SEPARATE PERMITS WHICH WOULD INCLUDE FEES, BUILDING | | PERMIT APPLICATIONS, PLANS AND REVIEWS. | | | | 16. FBC 107, AN INDEX LOCATED AT THE BEGINNING OF THE | | DIGITAL ROLL OF PLANS WOULD BE HELPFUL. THE PLANS ARE | | ORDERED IN THIS MANNER: | | | | INDEX FOR PHASE I FOR ARCH/STRUCTURAL ONLY | | PHASE I PAGES FOR LIFE SAFETY, CIVIL, LANDSCAPE, | | STRUCTURAL, DEMO, SITE, ARCH | | INDEX FOR PHASE II FOR ARCH/STRUCTURAL ONLY | | PHASE I PAGES FOR LIFE SAFETY, CIVIL, LANDSCAPE, | | STRUCTURAL, DEMO, SITE, ARCH | | FMEP INDEX FOR PHASE II | | FMEP SHEETS | | FMEP INDEX FOR PHASE I | | FMEP INDEX | | | | SINCE THERE ARE 577 PLAN PAGES FOR THIS PROJECT, PLEASE | | PROVIDE AN INDEX AT THE BEGINNING OF THE DIGITAL ROLL. | | ALTHOUGH A COMPLETE SHEET INDEX IS NOT REQUIRED, AN | | INDEX WHICH SHOWS THE SERIES ORDER WOULD BE HELPFUL, | | ESPECIALLY AS PHASE II FMEP PAGES ARE LOCATED BEFORE | | PHASE I FMEP. | | | | 17. FBC 107, SHEET WHICH IS LABELED 201 - A626.PDF IS | | IN THE MIDDLE OF THE CIVIL SHEETS FOR PHASE II. PLEASE | | COORDINATE TO HAVE THIS PAGE RELOCATED SO IT IS IN | | NUMERICAL ORDER, ARCHITECTURAL SHEETS. | | | | THIS ALSO APPLIES TO SHEETS: | | 202 ? A630 (BETWEEN L AND S SHEETS, PHASE II) | | 204 - A642 | | 206 - A644 | | 209 - IN101C | | 210 - IN101D | | 2-110 ? G000B | | | | THIS MAY NOT BE A COMPLETE LIST. CHECK ALL PRIOR TO | | RESUBMITTAL. DUE TO NAMING CONVENTION, THE SERIES OF | | SHEETS DO NOT APPEAR IN THE ORDER ON THE DRAWING | | SCHEDULE, AND FMEP ARE NOT INCLUDED (HAVE THEIR OWN | | INDEXES). DUE TO THE SIZE OF THIS PLAN, WHILE NOT | | REQUIRED TO BE IN ORDER OF THE INDEX (ALTHOUGH THAT | | WOULD BE HELPFUL), THE SERIES SHOULD BE TOGETHER AND IN | | THE ORDER ON THE INDEX FOR THAT SERIES. | | | | 18. FBC ENERGY CONSERVATION 103.2.1.2, ENERGY CALCS | | REQUIRED. | | | | 19. G001, IT APPEARS THAT THE PROPOSED BUILDING WILL BE | | USED AS EITHER ASSISTED LIVING OR INDEPENDENT LIVING | | WHICH ARE REGULATED BY FAIR HOUSING ACT, FBC 2010 | | ACCESSIBILITY. SHEET G001 HAS A LINE WHICH STATES THAT | | PER 11 9.1.4, NINE UNITS ARE REQUIRED TO BE ACCESSIBLE. | | PLEASE REVISE THIS INFORMATION TO CLARIFY. IF THIS IS | | EITHER ASSISTED LIVING OR INDEPENDENT LIVING, | | ACCESSIBILITY DOES NOT APPLY TO THE RESIDENTIAL PORTION | | OF THE BUILDING, BUT APPLIES TO PORTIONS OF THE AMENITY | | AND BUSINESS AREAS. ALSO, THIS REFERENCE APPEARS TO BE | | FROM FBC 2007; THIS SPECIFIC SECTION IS FOR TRANSIENT | | LODGING. PER FAIR HOUSING, ALL UNITS ARE TO CONSIDERED | | COVERED UNITS AND ARE TO COMPLY WITH THE REQUIREMENTS | | IN SECTION 3, 100.205 C. | | | | IF THE UNITS ARE NOT EITHER INDEPENDENT OR ASSISTED | | LIVING UNITS, PLEASE REVISE PLAN TO CLARIFY. | | | | 20. UNIT PLANS HAVE NOT BEEN REVIEWED AS ALL | | INFORMATION PROVIDED INDICATES THAT THEY ARE SUBJECT TO | | FAIR HOUSING, BUT NO INFORMATION REGARDING WAS PROVIDED | | ON THE UNIT PLANS, AND ACCESSIBLE UNITS ARE SHOWN. A | | REVIEW CANNOT BE DONE WITHOUT MORE INFORMATION, FBC | | 107. | | | | 21. PHASE II SHEET A101, CLARIFY USE OF GUEST ROOM 105 | | (REVISE PLAN TO INCLUDE INTENDED USE). IF THIS IS A | | ROOM AVAILABLE FOR RENT, IT APPEARS THAT THIS UNIT | | WOULD BE SUBJECT TO ALL REQUIREMENTS OF FBC 2010 | | ACCESSIBILITY. ALSO, ONE PUBLIC ACCOMODATION ROOM MAY | | CAUSE OTHER AREAS (SUCH AS THE POOL) TO BE SUBJECT TO | | ACCESSIBILITY (IN PARTICULAR, SEE FBC 2010 | | ACCESSIBILITY 1004, 1009). | | | | 22. G001, REQUIREMENTS ARE STATED BUT SOME THINGS ARE | | NOT CLEAR AS TO JOB SPECIFIC APPLICABLILITY. WILL THIS | | BUILDING BE CONSIDERED AN ADDITION TO THE EXISTING | | RESIDENTIAL TOWER (TRADITION 1), OR IS IT DESIGNED AS A | | SEPARATE BUILDING? SHOW COMPLIANCE WITH FBC 2010 TABLE | | 503. NO INFORMATION PROVIDED REGARDING THE EXISTING | | BUILDING. | | | | EITHER THIS IS ONE LARGE BUILDING (PROVIDE INFORMATION | | REGARDING THE EXISTING BUILDING) OR TWO SEPARATE | | BUILDINGS WITH AN ASSUMED PROPERTY LINE (SHOW | | COMPLIANCE FBC 705.3. REVISE PLAN TO CLARIFY. | | | | 23. G101, IF TRADITION 1 AND TRADITION II ARE SEPARATE | | BUILDINGS, A 2 HOUR FIRE WALL IS SHOWN, 3 HOURS | | REQUIRED PER FBC TABLE 706.4. | | | | 24. G101, IF TRADITION 1 AND TRADITION II ARE SEPARATE | | BUILDINGS, THE FIRE WALL IS TO COMPLY WITH THE | | REQUIREMENT OF 706.2, STRUCTURAL INTEGRITY. | | | | 25. G101, CLARIFY THE EXIT STRATEGY FOR THE CONNECTING | | DOOR BETWEEN TRADITION I AND II. IF THIS IS AN EXIT FOR | | BOTH SIDES, HOW WILL THE DOOR SWING IN BOTH DIRECTIONS, | | AND HOW WOULD YOU CONTROL CONFLICTS SUCH AS OCCUPANTS | | TRAVELING IN OPPOSITE DIRECTIONS? IT IS NOT CLEAR HOW | | THE FIRE WALL WILL ALLOW OCCUPANTS TO PASS THROUGH. IF | | THIS IS TO BE A MCKEON DOOR, IT IS NOT CLEAR HOW THIS | | WILL MEET THE STRUCTURAL INTEGRITY REQUIREMENT. | | | | REVISE PLAN TO INCLUDE A DETAIL FOR THE PROPOSED FIRE | | WALL AND CLARIFY THE ABOVE CONCERNS, FBC 107. | | | | 26. G101, CORRIDOR 187 IS NOT A RATED CORRIDOR BUT | | SERVES THE RESIDENTIAL UNITS AS THERE IS AN EXIT SIGN | | FROM CORRIDOR 188 TO CORRIDOR 187, FBC TABLE 1018.1. | | THERE IS A NOTE WHICH STATES THAT TRAVEL DISTANCE IS | | 134FT, BUT IT IS NOT CLEAR WHERE THIS IS APPLICABLE. | | | | 27. A101, FBC 1022.4, STAIR 1, OPENINGS INTO THE STAIR | | ARE LIMITED TO THOSE REQUIRED FOR EXITING. THE | | RATIONALE FOR HAVING AN EXIT FOR THE CHILLERS GO | | THROUGH THE EXIT FOR THE RESIDENTIAL IS NOT CLEAR; IF | | TWO EXITS ARE REQUIRED FROM THIS SPACE, IT APPEARS THAT | | THERE IS ENOUGH ROOM TO ADD A DOOR IN ANOTHER LOCATION. | | | | 28. SOME MECHANICAL SHEETS DO NOT SHOW THE REQUIRED | | FIRE RATING (FBC708) FOR THE ADJACENT SHAFT FOR THE | | PRESSURIZED STAIRS (FOR INSTANCE, 305 M202A), PLEASE | | CORRELATE. | | | | 29. G001 MAKES REFERENCE TO THE EXCEPTION FOR A 1 HOUR | | SHAFT RATING PER FBC 403.2.1.2. INCORPORATE THIS | | REQUIREMENT INTO THE FIRE PROTECTION SHEETS. A BUILDING | | REVIEW WILL BE DONE IN ADDITION TO FIRE AND MECHANICAL | | REVIEWS WHEN THE FIRE SPRINKLER PERMIT APPLICATION AND | | PLANS ARE SUBMITTED. NOTE THAT FLOOR PLANS SHOW A 2 | | HOUR SHAFT RATING. CLARIFY WHERE THIS EXCEPTION WILL | | APPLY. IF THIS EXCEPTION DOES NOT APPLY, REMOVE FROM | | PLAN AND ADVISE. | | | | 30. G101 AND OTHER PAGES, REVISE LIFE SAFETY PLAN TO | | SHOW EXIT DISCHARGE TO THE PUBLIC WAY FOR ALL EXITS. | | | | EXIT DISCHARGE NOT CLEAR FOR THE EXITS WHICH OPEN TO | | THE POOL AREA AND FOR THE EXITING FROM CORRIDOR THROUGH | | THE DINING ROOM EXTENSION, FBC 1027. EXIT STRATEGY IS | | NOT CLEAR. SEE FIRE COMMENTS. SEE ALSO 1004.8 (OUTDOOR | | AREAS), 1006.1.1 (ILLUMINATION). TWO REQUIRED EXITS | | FROM DINING ROOM OPEN INTO THE POOL AREA. THE POOL AREA | | ITSELF HAS A HIGH OCCUPANT LOAD. IT IS NOT CLEAR HOW | | HUNDREDS OF OCCUPANTS WILL TRAVEL FROM THE POOL AREA TO | | THE PUBLIC WAY; ONLY A SMALL GATE IS SHOWN AND THE | | OCCUPANTS WILL HAVE TO CROSS AN AREA MARKED FOR THE | | FIRE TRUCK. | | | | OTHER EXITS SHOW SIDEWALKS BUT ACCESS TO THE PUBLIC WAY | | (OR OTHER APPROVED AREA) IS NOT CLEAR. FOR INSTANCE, | | FP001 SHOWS A SIDEWALK FOR EXIT STAIRS 3 AND 4 WHICH | | LEADS BACK INTO THE BUILDING. | | | | 31. G101, STAIR 4, FBC 1022.6, IN ORDER TO FACILITATE | | PHASE II, THE EXTERIOR WALL IS TO BE FIRE RESISTANCE | | RATED (LESS THAN 180DEGREES WHEN PHASE II IS BUILT). | | | | 32. G101, THEATER VESTIBULE AND MULTIPURPOSE ROOM (ALSO | | REFERRED TO AS THEATER ON SHEET G001, USE GROUP | | CLASSIFICATION) IS SHOWN AS GROUP A1. SHEET G001 ALSO | | REFERS TO MULTIPURPOSE AS A3. | | | | 33. A101, SHOW 18IN MANEUVERING CLEARANCE PULL SIDE, | | FOR THE FOLLOWING DOORS PER FBC 2010 ACCESSIBILITY | | 404.2.4: | | | | AEROBICS ROOM 146 | | ACCESSIBLE CHANGING ROOM 149 | | | | 34. A101A, WHEN RESUBMITTING, INCLUDE SEATING PLAN FOR | | THE MULTIPURPOSE ROOM. | | | | NOTE: SEATING REVIEWED IN PLANGRID, A101A. FORTY SEVEN | | FIXED SEATS SHOWN, OCCUPANT LOAD IS 51. | | | | REVISE PLAN TO INCLUDE INFORMATION REGARDING THE USE OF | | THIS SPACE. WILL THIS BE ONLY FOR RESIDENTS AND THEIR | | GUESTS (FAIR HOUSING), OR WILL TICKETS EVER BE SOLD TO | | THE GENERAL PUBLIC (ACCESSIBILITY)? | | | | NO ACCESSIBLE SEATING IS SHOWN. SEE FBC 2010 | | ACCESSIBILITY 802 REGARDING WHEELCHAIR SPACES, SIGHT | | LINES, AND COMPANION SPACES REQUIRED. REVISE PLAN TO | | CLARIFY COMPLIANCE FOR ACCESSIBILITY OR FAIR HOUSING | | (REQUIREMENT THAT ALL PUBLIC AND COMMON USE AREAS ARE | | READILY ACCESSIBLE TO AND USABLE BY DISABLED PERSONS) | | AS APPLICABLE. | | | | 35. EXERCISE AREAS, MULTIPURPOSE ROOM (SEE OTHER | | COMMENT), SALON, SPA, POOL, DINING, GUEST ROOM, ALL | | COMMON AREAS, REVISE PLAN TO INDICATE WHETHER THESE | | AREAS ARE FOR RESIDENTS AND THEIR GUESTS ONLY (SUBJECT | | TO FAIR HOUSING ONLY) OR IF THE PORTION OF THE FACILITY | | IS OPEN TO NON RESIDENTS FOR A FEE, OR AVAILABLE FOR | | EMPLOYEE USE (SUBJECT TO ACCESSIBILITY AS WELL AS FAIR | | HOUSING). | | | | 36. G101 AND A213, THE DOORS FOR THE MULTI PURPOSE ROOM | | INCLUDE SIDELIGHTS WHICH APPEAR TO BE IDENTICAL TO THE | | DOORS BUT DO NOT OPERATE. SEE FBC 1008.1, REVISE PLAN | | TO SHOW HOW THE DOORS WILL BE EASILY DISTINGUISHABLE | | FROM THE INOPERABLE SIDELITES. | | | | 37. G101 OR RELATED A SHEET, REVISE PLAN TO INCLUDE | | INFORMATION REGARDING WHAT WILL BE STORED IN THE | | CHEMICAL ROOM 137A (ASSOCIATED WITH SALON), FBC 107, | | FBC 307. PLAN SHOULD INCLUDE A BRIEF DESCRIPTION OF | | CHEMICALS TO BE STORED AND, IF ANY CHEMICALS ARE THOSE | | LISTED IN FBC307, INCLUDE CHEMICAL AND AMOUNT TO SHOW | | THAT IT IS BELOW THE ALLOWABLE LIMIT. | | | | 38. G101, AEROBICS 146 AND FITNESS 143 APPEAR TO HAVE | | AN OCCUPANT LOAD OVER 50, BUT SECOND EXIT ACCESS NOT | | CLEAR. AEROBICS ROOM HAS TWO DOORS BUT BOTH LEAD TO | | SAME CORRIDOR (COMMON PATH). FITNESS ROOM HAS ONLY ONE | | EXIT ACCESS. TWO MEANS OF EGRESS REQUIRED FROM SPACES | | WITH AN OCCUPANT LOAD OVER 50, TWO EXITS REQUIRED FOR | | THE AREA. | | | | 39. G101, CORRIDOR 146A APPEARS TO EXCEED DEAD END | | CORRIDOR LIMIT, FBC 1018.4. REVISE PLAN TO ADDRESS. | | | | 40. G101, FBC 303, FITNESS LOUNGE, FITNESS, AEROBICS, | | BREAK ROOM, CONFERENCE ROOM, LIBRARY ARE ASSEMBLY | | OCCUPANCY, FBC 303. PROVIDE OCCUPANT LOAD (TABLE | | 1004.1.1, EXERCISE ROOMS) AND SEPARATION BETWEEN | | ASSEMBLY AND BUSINESS UNLESS EXCEPTION APPLIES. IF | | COVERED UNDER AN EXCEPTION, INCORPORATE INTO PLAN (FBC | | 508.1, 508.2 AND COMMENTARY). | | | | 41. LIVING ROOM LIBRARY IS SHOWN AS A CIRCULATION AREA | | WITH OCCUPANT LOAD BASED ON 200 SF PER PERSON. FBC | | TABLE 1004, READING ROOMS ARE TO HAVE AN OCCUPANT LOAD | | OF 50 SF PER PERSON. REVISE PLAN TO CLARIFY THE USE AND | | OCCUPANT LOAD FOR THIS AREA. | | | | 42. G101, REVISE PLAN TO INCLUDE OCCUPANT LOAD AND AREA | | FOR THE FITNESS ROOM AND AEROBICS ROOM (SEPARATELY AS | | THE LARGER AREA CAN BE COMBINED TO TWO SMALLER AREAS). | | AS IT APPEARS THAT THE AEROBICS AND FITNESS AREA | | OCCUPANT LOAD WILL BE OVER 50, DOORS ARE TO SWING IN | | THE DIRECTION OF TRAVEL, FBC 1008.1.2. | | | | 43. AS IT APPEARS THAT THE AEROBICS AND FITNESS AREA | | OCCUPANT LOAD WILL BE OVER 50, FIRE EXIT HARDWARE OR | | PANIC HARDWARE REQUIRED FOR THOSE DOORS AND ALL OTHER | | DOORS IN THE MEANS OF EGRESS, FBC 1008.1.10, 1004.9. | | | | 44. EGRESS GATE IS REQUIRED TO HAVE EITHER FIRE EXIT | | HARDWARE OR PANIC HARDWARE, FBC 1008.1.10, 1008.2. | | REVISE PLAN TO INCLUDE THE REQUIREMENT OR DETAIL. | | | | 45. G101, FBC 911.1.1, FIRE COMMAND CENTER ROOM SHALL | | BE A MINIMUM OF 200 SF AND A MINIMUM DIMENSION OF 10FT; | | REVISE PLAN TO SHOW COMPLIANCE WITH SIZE REQUIREMENT. | | | | 46. G101, FBC 911.1.2, FIRE COMMAND CENTER ROOM | | REQUIRES A 1 HOUR FIRE BARRIER; THIS IS SHOWN AT THE | | CORRIDOR BUT NOT BETWEEN FIRE COMMAND CENTER AND | | CHILLERS RM 182. | | | | 47. G101, PROVIDE OCCUPANT LOAD FOR DINING F. IF THE | | OCCUPANT LOAD IS OVER 50, TWO EXITS REQUIRED. REQUIRED | | MEANS OF EGRESS DOORS ARE TO BE SIDE SWINGING; A | | SLIDING DOOR IS SHOWN AS SECOND MEANS OF EGRESS, FBC | | 1008.1.2. | | | | 48. FBC 911.1.4, LAYOUT OF FIRE COMMAND CENTER AND ALL | | FEATURES REQUIRED BY 911.1.5 TO BE SUBMITTED AND | | APPROVED PRIOR TO INSTALLATION. | | | | 49. TK G102, RATING BETWEEN STAIR 2, STAIR 4 IS SHOWN | | BETWEEN ADJACENT SHAFTS FOR PRESSURIZATION ON SHEET | | M202A, G102 SHOWS THE RATING OUTSIDE THE SHAFT (BETWEEN | | SHAFT AND CORRIDOR). | | | | 50. G102 AND OTHER FLOORS, PROVIDE OCCUPANT LOAD AND | | OCCUPANCY CLASSIFICATION FOR THE COMMUNITY ROOM AND | | CONCIERGE 936, FBC 107, SEE ALSO FBC 508.2. | | | | NOTE THAT IF OCCUPANT LOAD IS 50 OR MORE, TWO EXITS ARE | | REQUIRED. | | | | 51. A610, REVISE DOOR NOTE (GENERAL GLAZING | | REQUIREMENTS) TO UPDATE CODE REFERENCE (FBC 2007). | | | | 52. DOOR SCHEDULE HAS A COLUMN FOR ?ELECTRIC? BUT THAT | | COLUMN IS BLANK. IT APPEARS THAT THIS SHOULD BE | | APPLICABLE FOR SLIDING DOORS IN THE REQUIRED MEANS OF | | EGRESS AND EXIT. EXIT DOOR 122 (DOOR TYPE G1) SHOULD | | ALSO COMPLY WITH FBC 1008.1.4.2, 1008.1.4.3. | | | | 53. A601 AND G101, DOORS IN FIRE BARRIERS REQUIRE A 45 | | MINUTE FIRE RATING, FBC TABLE 715.4. IT IS NOT CLEAR | | WHICH DOORS ARE BEING CONSIDERED IN A CORRIDOR RATHER | | THAN AN OCCUPANCY SEPARATION. SEE DOORS 173C, 182, 172, | | 183. | | | | DOOR 173C IS A 20 MINUTE DOOR, BUT THE CORRIDOR 184 | | RATING IS NOT CONTINUOUS AS IT APPEARS TO TRANSITION | | INTO THE GALLERY. USE OF CORRIDORS, INCIDENTAL AND | | ACCESSORY USES FBC 508 ARE NOT ENTIRELY CLEAR. IF ANY 1 | | HOUR RATINGS ON THE PLAN ARE REMOVED WHEN RESUBMITTING, | | PLEASE ALSO NOTE ALSO SMOKE AND PROTECTION REQUIREMENT | | IN 508.2.5.2. | | | | 54. S8.1 AND G000 PHASE I AND II, MAP FOR IMPORTANCE | | FACTOR III & IV IS INCLUDED, BUT SHEET S8.1 STATES | | DESIGN CRITERIA AS RISK CATEGORY II; PLEASE CORRELATE. | | | | IN ORDER TO ESTABLISH RISK CATEGORY, PROVIDE TOTAL | | BUILDING OCCUPANT LOAD. AT THIS POINT IT IS NOT CLEAR | | WHETHER THE TOTAL OCCUPANT LOAD SHOULD INCLUDE | | TRADITION I AND TRADITION II, OR IF THE TWO WILL BE | | DESIGNED AS SEPARATE BUILDINGS. | | | | 55. S8.1, SOME STANDARD REFERENCES REFER TO "LATEST | | EDITION." PLEASE REVISE TO BE THE VERSION SPECIFIED IN | | FBC CHAPTER 35. | | | | 56. S9.1, SECTION 9 AND OTHER PLACES, PLYWOOD | | SPECIFIED. FBC 603.1, PLEASE REVISE TO FRT. | | | | 57. AN ENCLOSED ELEVATOR LOBBY IS NOT SHOWN. FBC | | 708.14.1, PLEASE ADVISE AS TO WHICH EXCEPTION IS BEING | | USED IN THIS DESIGN AND WHERE THIS INFORMATION CAN BE | | LOCATED ON THE PLAN. | | | | 58. A002 AND OTHER SHEETS REFER TO UL ASSEMBLIES. | | INCORPORATE DETAILS WITH SPECIFIC OPTIONS INTO THE PLAN | | OR THIS PERMIT WILL BE ISSUED WITH PROVISO THAT THE | | DETAILS BE SUBMITTED PRIOR TO INSTALLATION, AFTER | | REVIEW BY DESIGNER OF RECORD. | | | | 59. A101, A "W" SHAPE APPEARS IN FRONT OF DOORS AT 186 | | ELEVATOR LOBBY AND 118 WOMEN WHICH DOES NOT APPEAR ON | | OTHER SHEETS, CLARIFY, FBC 107. | | | | 60. FBC 1207, PROVIDE THE FOLLOWING TEST REPORTS FOR | | THE FLOORING UNDERLAYMENT WILL BE REQUIRED AS | | APPLICABLE (INFORMATIONAL NOTE: PER S2.4, S3.1 FLOOR | | SLABS ARE 8IN, SO STC AND IIC TESTS ON AN 8IN SLAB OR | | LESS ARE ACCEPTABLE): | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, | | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED | | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE | | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL | | NOT BE ALTERED. | | | | PLEASE PROVIDE A COPY OF THE TEST REPORT. | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART | | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN | | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW | | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT | | BELOW WILL NOT BE ALTERED. | | | | PLEASE PROVIDE A COPY OF THE TEST REPORT. | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | E 84 OR UL 723. | | | | IF THIS INFORMATION IS NOT PROVIDED PRIOR TO PERMIT | | ISSUANCE, PERMIT WILL BE ISSUED WITH PROVISO THAT THIS | | BE SUBMITTED PRIOR TO INSTALLATION. REVIEW BY DESIGNER | | OF RECORD REQUIRED PRIOR TO SUBMITTAL, FBC 107.3.4.1. | | | | 61. PROVIDE THE GEOTECHNICAL REPORT FOR THIS PROJECT, | | FBC 1803. THE SOILS REPORT IS TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | | 62. FBC 107, PROVIDE THE SURVEY FOR THIS PROPERTY. | | | | 63. THE PLANS INDICATE THERE WILL BE A POOL BUILT VERY | | CLOSE TO THIS BUILDING PLEASE PROVIDE HOW THE | | FOUNDATION /FOOTING WILL BE PRESERVED WHILE THE POOL IS | | BEING EXCAVATED? 1808.7. | | | | 64. 2010 FBC-B 1816.1 TERMITE PROTECTION. TERMITE | | PROTECTION SHALL BE PROVIDED BY REGISTERED | | TERMITICIDES, INCLUDING SOIL-APPLIED PESTICIDES, | | BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR | | OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED | | FOR USE AS A PREVENTATIVE TREATMENT TO NEW | | CONSTRUCTION. SEE SECTION 202, REGISTERED TERMITICIDE. | | UPON COMPLETION OF THE APPLICATION OF THE TERMITE | | PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL | | BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED | | PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING | | STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE | | TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. | | TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS | | ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE | | AND CONSUMER SERVICES." | | | | 65. BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 66. PLEASE PROVIDE DOCUMENTATION HOW THE JOBSITE WILL | | COMPLY WITH : | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 110.7 IMPACT OF | | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY | | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO | | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, | | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID | | PROPERTY PURSUANT TO A CONSENT GRANTED BY THE | | APPLICABLE PROPERTY OWNER, UNDER TERMS OR CONDITIONS | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | INCLUDES, BUT IS NOT LIMITED TO, THE CONTROL OF DUST, | | NOISE, WATER OR DRAINAGE RUN-OFFS, DEBRIS, AND THE | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC | | SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS OF ALL | | NEW RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, | | POOLS, PATIOS, DRIVEWAYS, DECKS OR SIMILAR ITEMS, ON | | EXISTING PROPERTIES RESULTING IN A SIGNIFICANT DECREASE | | OF PERMEABLE LAND AREA ON ANY PARCEL OR HAS ALTERED THE | | DRAINAGE FLOW ON THE DEVELOPED PROPERTY SHALL, AS A | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | OF THE FINAL INSPECTION. | | | | 2ND REVIEW; A STATEMENT IT TYPICALLY INCORPORATED INTO | | THE PLAN. | | | | 67. G101, REVISE LIFE SAFETY PLAN TO INCLUDE WORST CASE | | WITH TRAVEL DISTANCE FOR EACH AREA (NOT NECESSARY FOR | | EACH ROOM). PATH OF TRAVEL IS TO BE SHOWN ACROSS THE | | DIAGONAL OF THE ROOMS. FBC 1016.1, THIS SHOULD BE SHOWN | | ALONG THE NATURAL UNOBSTRUTED PATH OF TRAVEL. AS | | FURNITURE WILL BE PLACED IN THE CENTER OF THE ROOM, THE | | PATH SHOULD BE MEASURED ALONG THE ROOM PERIMETER. | | | | 68. SEE OTHER COMMENTS, SHAFT RATING PROPOSED NOT | | CLEAR. PLEASE CLARIFY SHAFT RATING FOR ELEVATOR 2 PHASE | | I, A 1 HOUR SHAFT IS SHOWN, BUT A 2 HOUR SHAFT IS SHOWN | | FOR ELEVATOR 1 | | | | 69. S2.1 APPEARS TO HAVE A TYPO, TOP RIGHT, NOTE | | (STATES "PER ACI 18.12.4"); PLEASE CORRECT OR CLARIFY | | AS APPLICABLE. PLEASE ALSO REVISE OTHER AFFECTED | | SHEETS. | | | | 70. SECTION 1 S4.1, ALSO SECTION 5 AND OTHER PLACES, | | PLYWOOD SHEATHING SHOWN. FBC 602.1, REVISE TO INCLUDE | | REQUIREMENT FOR FRT (ALSO TO CORRELATE WITH A101 AND | | OTHER SHEETS), FBC 603.1.1.1.3. | | | | 71. PROVIDE INFORMATION FOR THE MCKEON DOOR (SPEC | | SHEETS AND TEST REPORT), INSTALLATION INSTRUCTIONS. | | ALSO DISCUSSED IN THE MEETING WAS THE PRACTICALITY FOR | | ACCESS FOR MAINTENANCE, FBC 107. | | | | 72. 50. FBC 2010 ACCESSIBILITY 703, SIGNS TO COMPLY | | WITH THIS SECTION. | | | | 73. PLANS IN MANY LOCATIONS USE THE LANGUAGE "UNDER | | SEPARATE PERMIT" (FOR INSTANCE, SHEET 036 - S6.2). IF | | ALL WORK TO BE INCLUDED IN THIS PERMIT, REVISE | | LANGUAGE. IF THIS IS PROVIDED FOR INFORMATION ONLY, | | PLEASE ADVISE. | | | | 74. INCORPORATE FIRE RATING REQUIREMENTS AND DETAILS | | FOR THE FLOOR, STRUCTURAL ELEMENTS FBC TABLE 601. | | | | 75. PLEASE IDENTIFY THE RECTANGLE ADJACENT TO THE SINK | | IN THE GUEST ROOM, S1.2 AND OTHER PAGES. | | | | 76. PROVIDE A DETAIL FOR THE OVERFLOW SCUPPER, FBC 107 | | (OR ADVISE AS TO WHERE THIS CAN BE LOCATED). | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-01-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-01-10 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-01-10 |
Time |
10:28 |
Sent To |
|
|
Notes |
2015-01-07 17:15:45 | | | BUILDING PLAN REVIEW | | PERMIT: 14120909 | | ADD: 4920 LORING DR. | | CONT: THE WHITING TURNER CO. | | CONTACT: RYAN TEMPONE | | E-MAIL: [email protected] | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW- FOUNDATION PERMIT | | DATE: SAT. JAN. 10/ 2015 | | ACTION: DENIED | | | | NOTE: FOUNDATION PERMIT/ PHASED PERMITING. 2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION | | 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL OF THE | | APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | 1) MISSING INFORMATION EVEN FOR A FOUNDATION PERMIT: | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION | | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1.1 COMMERCIAL BUILDINGS: | | 1.1) SITE PLAN SHOWING LOCATION OF THE NEW BUILDING AND | | THE RELATIONSHIP OF OTHER BUILDINGS, PROVIDE DISTANCES | | BETWEEN. | | 1.2) SURVEY WITH FLOOD ZONE DESIGNATION | | 1.3) SOILS REPORT WITH THE MINIMUM BEARING VALUE FOR | | THIS BUILDING | | 1.4) A ARCHITECTURAL SHEET SHOWING THE 1ST FLOOR OR | | BOTTOM FLOOR, WITH FINISH FLOOR ELEVATIONS. | | 1.5) OCCUPANCY TYPE | | 1.6) MINIMUM BUILDING TYPE/ NUMBER OF STORIES | | | | 2) SINCE THE TRADITION TOWER WILL BE ASSUMED THE 10 | | STORY THERE HAS BEEN DISCUSSION ABOUT, THIS BUILDING | | WOULD BE CLASSIFIED AS A THRESHOLD BUILDING BY | | DEFINITION AND NEED TO MEET THE STATE REQUIREMENTS FOR | | SUCH A BUILDING. NOTE SHEET S-1.1 DRAWING INDEX | | INDICATES 10 FLOOR FRAMING PLAN. | | | | NOTE :THRESHOLD FORMS WERE E-MAILED TO RYAN TEMPONE | | 1/10/2015 01:05 PM. | | | | THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | THE | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | 2A) SHEET S-8.10THRESHOLD INSPECTION NOTES NOT INCLUDED | | IN THIS SUBMITTAL. 109.3.6.1 THE ENFORCING AGENCY SHALL | | REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL | | INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A | | (WRITTEN/ TYPED) STRUCTURAL INSPECTION PLAN PREPARED BY | | THE ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN | | MUST BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | DOCUMENTS. | | | | 2B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE INSPECTION COMPANY & | | THRESHOLD INSPECTOR WILL NEED TO FILL OUT THE SPECIAL | | INSPECTOR AGREEMENT FORMS AND RESUBMIT TO THE CITY FOR | | REVIEW. CONTACT KEN CONRAD MANAGER OF THE SPECIAL | | INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER | | INFORMATION | | BEFORE THE PERMIT MAY BE ISSUED. | | | | 2C) THRESHOLD BLDG, REQUIRED STATEMENT: W.P.B. | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | BEST OF THE ARCHITECT'S PR ENGINEER'S KNOWLEDGE, THE | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | AUTHORITY IN | | ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. | | | | 2D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | CONTACT KEN CONRAD | | TEL: 561-805-6666 | | E-MAIL: [email protected] | | | | 2E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE | | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: | | [email protected] | | | | 2F) NOTE THIS IS A DIGITAL PLAN, AFTER PERMIT ISSUANCE, | | THE PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND | | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO | | SETS OF PLANS WILL NEED TO BE PRINTED IN COLLOR, (1) | | FOR THE THRESHOLD INSPECTOR, THE OTHER FOR THE MEP | | INSPECTORS. | | | | 2G) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS. | | | | 3) PLEASE PROVIDE DOCUMENTATION HOW THE JOBSITE WILL | | COMPLY WITH : | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 110.7 IMPACT OF | | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY | | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO | | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, | | UNLESS SUCH ACTIVITY IS | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | GRANTED BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS | | OR CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | OWNER. THIS INCLUDES, BUT IS NOT LIMITED TO, THE | | CONTROL OF DUST, NOISE, WATER OR DRAINAGE RUN-OFFS, | | DEBRIS, AND THE STORAGE OF CONSTRUCTION MATERIALS. NEW | | CONSTRUCTION ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL | | HISTORIC SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS OF ALL | | NEW RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, | | POOLS, PATIOS, DRIVEWAYS, DECKS OR SIMILAR ITEMS, ON | | EXISTING PROPERTIES RESULTING IN A SIGNIFICANT DECREASE | | OF PERMEABLE LAND AREA ON ANY PARCEL OR HAS ALTERED THE | | DRAINAGE FLOW ON THE DEVELOPED PROPERTY SHALL, AS A | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | OF THE FINAL INSPECTION. | | | | 4) 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | 5) THE (4) FOUNDATION SHEETS SUBMIITED DOES NOT HAVE | | ENOUGH INFORMATION ON THESE SHEETS WITH DIMENSIONS, NOR | | STEEL LAYOUT FOR THE VERTICAL COLUMNS, NOR COLUMN | | SIZES. THE DETAIL SHEETS AND SECTIONS FOR ELEVATOR PITS | | ARE ALSO MISSING FROM THIS SUBMITTAL, THE MINIMUM | | BEARING VALUE NOT PROVIDED, MINIMUM CONCRETE DESIN MIX, | | THERE IS NOT ENOUGH INFORMATION PROVIDED TO DO A | | THROGOUGH REVIEW. | | | | 6) THE PLANS INDICATE THERE WILL BE A POOL BUILT VERY | | CLOSE TO THIS BUILDING PLEASE PROVIDE HOW THE | | FOUNDATION /FOOTING WILL BE PRESERVED WHILE THE POOL IS | | BEING EXCAVATED? 1808.7. | | | | 7) 2010 FBC-B 1816.1 TERMITE PROTECTION. TERMITE | | PROTECTION SHALL BE PROVIDED BY REGISTERED | | TERMITICIDES, INCLUDING SOIL-APPLIED PESTICIDES, | | BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR | | OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED | | FOR USE AS A PREVENTATIVE TREATMENT TO NEW | | CONSTRUCTION. SEE SECTION 202, REGISTERED TERMITICIDE. | | UPON COMPLETION OF THE APPLICATION OF THE TERMITE | | PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL | | BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED | | PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING | | STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE | | TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. | | TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS | | ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE | | AND CONSUMER SERVICES." | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-08-27 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2015-08-27 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2015-08-27 |
Time |
10:19 |
Sent To |
|
|
Notes |
2015-08-27 10:24:11 | NOTES ADDED TO PLANS FOR FIELD EVALUATION AND | | COMPLIANCE WITH GOVERNING CODES | | ENTIRE INSTALLATION SUBJECT TO FIELD INSPECTION AND | | REQUIREMENTS OF THE GOVERNING CODES. | | PLANS ARE BEING NOTED FOR COMPLIANCE AND AS-BUILT MAY | | BE REQUIRED IF DEVIATIONS ARE REQUIRED FOR COMPLIANCE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-23 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-11 |
Time |
10:32 |
Sent To |
|
|
Notes |
2015-06-23 15:12:32 | 6/12/2015 | | PROJECT: MORSE SENIOR CENTER PHASE | | PERMIT#: 14120909 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) CLARIFICATION IS REQUIRED. THE APPLICATION SUBMITTED | | WITH THESE PLANS STATE "FOUNDATION ONLY" HOWEVER THE | | PLANS ARE A FULL SET FOR CONSTRUCTION OF A HIGH RISE. | | | | 2) G001 | | UNDER APPLICABLE CODES LIST TOP LEFT OF THE PAGE ADD | | THE 2008 EDITION OF THE NATIONAL ELECTRICAL CODE | | | | 3) E000 | | UNDER CODES AND STANDARDS LIST TOP RIGHT OF THE PAGE. | | CHANGE THE 2011 EDITION OF THE NATIONAL ELECTRICAL CODE | | TO THE 2008 EDITION OF THE NATIONAL ELECTRICAL CODE. | | | | 4) E001 | | SUBMIT MANUFACTURER DOCUMENTATION ON FIRE PUMP MOTOR | | AND CONTROLLER/ATS. INDICATE HP RATING LOAD AND VOLTAGE | | OF FIRE PUMP MOTOR. | | 4A) PROVIDE VERIFICATION ON THE PLANS THAT THE FIRE | | PUMP FEEDERS, CIRCUIT CONDUCTORS, GENERATOR CONTROL | | WIRING AND PUMP WIRING ARE APPROPRIATELY FIRE | | PROTECTED. INDICATE THE FIRE RATING AND MATERIAL | | REQUIRED. NEC 695.6, 695.14 | | | | 5) VERIFY THE FIRE PUMP FEEDERS ARE SIZED WITH A RATING | | NOT LESS THAN 125% OF THE SUM OF THE FIRE PUMP MOTOR, | | PRESSURE MAINTENANCE MOTORS AND 100 PERCENT OF THE | | ACCESSORIES. | | 5A) VERIFY THE MAXIMUM VOLTAGE DROP IS NOT MORE THAN 15 | | % BELOW NORMAL STARTING AND 5% BELOW WHEN THE MOTOR IS | | OPERATING AT 115% OF THE FULL LOAD CURRENT RATING. NEC | | 695.6, 695.7 | | | | 6) CLARIFY THE NEED FOR EMERGENCY POWER AND THEREFORE | | THE NEED FOR LEGALLY REQUIRED EMERGENCY GENERATOR OR | | SIMPLY A STANDBY STAND BY GENERATOR. | | | | 7) INDICATE THAT ALL WIRING FOR EMERGENCY LOADS WILL BE | | IDENTIFIED WITH PERMANENT MARKINGS AND KEPT ENTIRELY | | INDEPENDENT OF ALL OTHER WIRING AND EQUIPMENT. NEC | | 700.9 | | | | 8) PROVIDE PROPER SIGNAGE INDICATING THE TYPE AND | | LOCATION OF THE ON SITE EMERGENCY POWER SOURCE. NEC | | 700.8 | | 8A) PERMANENT PLAQUES OR DIRECTORIES SHALL BE INSTALLED | | AT EACH SERVICE DISCONNECT | | DENOTING ALL OTHER SERVICE LOCATION. NEC 230.2(E) | | | | 9) PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | 110.16. | | | | 10) PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN | | SHOWING COMPLIANCE WITH THE FLORIDA BUILDING ENERGY | | CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | 11) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS | | HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT | | NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | INTERRUPTED. NEC 110.9 | | | | 12) INDICATE COMPLIANCE WITH FBC-ENERGY. ELECTRICAL | | POWER AND LIGHTING SYSTEMS. (MANDATORY) FBC SECTION 505 | | 12A) PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN | | SHOWING COMPLIANCE WITH THE FLORIDA BUILDING ENERGY | | CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | 13) NEC 230.9(C) GROUND FAULT PERFORMANCE TESTING. THE | | GROUND-FAULT PROTECTION SYSTEM SHALL BE PERFORMANCE | | TESTED WHEN FIRST INSTALLED ON SITE. | | | | 14) PROVIDE A LAYOUT OF ALL ELECTRICAL ROOMS INDICATING | | COMPLIANCE WITH NEC 110.26 FOR ABOUT ALL ELECTRICAL | | EQUIPMENT. | | | | 15) E605 INDICATE THE LOAD CALCULATION FOR PANEL | | NLGP1A. THE LOAD CALCULATION IS CUT OFF BY PANEL | | NLGP1B. | | | | 16) CORRECT THE NAMING CONVENTION FOR THE ELECTRICAL | | SHEETS. THE ELECTRICAL SHEETS ARE NOT ALL TOGETHER. | | | | 17) CORRECT THE NAME OF PANEL RDPB. ON PAGE E005 IT IS | | NAMED RDPB BUT ON PG E001 IT IS NAMED RMDPB | | | | 18) E200A | | PROVIDE THE NOTES REFERENCED ON THE ENLARGED FLOOR PLAN | | UNITS E1 AND D2. THERE ARE PLAN NOTES SYMBOLS ON THE | | FLOOR PLANS BUT NO NOTES ANYWHERE ON THAT PAGE TO | | REFERENCE FOR CLARIFICATION. | | 18A) POWER PLAN NOTE 6. CALLS FOR A 20AMP CIRCUIT FOR | | DRYER BOOSTER FANS. | | BOOSTER FANS ARE NOT APPROVED FOR USE IN WPB PER THE | | WPB FIRE DEPT LOCAL CODES AND AMENDMENTS. | | | | 19) E200B | | PROVIDE THE NOTES REFERENCED ON THE ENLARGED FLOOR PLAN | | UNITS E1 AND D2. THERE ARE PLAN NOTES SYMBOLS ON THE | | FLOOR PLANS BUT NO NOTES ANYWHERE ON THAT PAGE TO | | REFERENCE FOR CLARIFICATION. | | | | 20) E200C | | CORRECT PLAN NOTE 1 TO PROVIDE AFCI CIRCUIT BREAKER ON | | ALL CIRCUITS WITHIN SLEEPING AREA TO READ ?ALL | | 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH | | CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT | | FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, | | LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, | | CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE | | PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, | | COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF | | THE BRANCH CIRCUIT.? PER NEC 210.12(B) | | 20A) ANYWHERE RECEPTACLES ARE INSTALLED WITHIN 6 FT OF | | THE SINK SHALL BE GFI PROTECTED. NEC 210.8(B)(5) | | | | 21) E202CPROVIDE A GFI WITHIN SIGHT OF MECHANICAL | | EQUIPMENT. NEC 210.63 SEE ALSO 210.8(A)(3). | | | | 22) E301A | | INDICATE HOW LIGHTING IS TO BE CONTROLLED THROUGHOUT. | | FBC 505.2 | | | | 23) E301B | | PROVIDE EMERGENCY AND EXIT LIGHTING AT STAIRS. | | INDICATE HOW LIGHTING IS TO BE CONTROLLED THROUGHOUT. | | FBC 505.2 | | | | 24) E310B | | PROVIDE EMERGENCY AND EXIT LIGHTING AT STAIRS. | | INDICATE HOW LIGHTING IS TO BE CONTROLLED THROUGHOUT. | | FBC 505.2 | | | | 25) E601 | | REVISE PANEL SCHEDULE AND LOAD CALCULATION. PANEL C2 | | INDICATES A 27KVA DEMAND LOAD AT ONLY 75AMPS. THIS | | SHOULD BE CLOSER TO 130AMPS. | | 23A) APPLY PANEL NOTE ?A? AT ALL CIRCUIT LOCATIONS | | REQUIRED. | | | | 26) E602 | | APPLY PANEL NOTE ?A? AT ALL CIRCUIT LOCATIONS REQUIRED | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | ARE REQUIRED FOR SWIMMING POOL, SITE LIGHTING, | | LIGHTNING PROTECTION, GENERATORS. HOOD EXHAUST, FIRE | | ALARM, ACCESS CONTROL SYSTEM, SECURITY, CCTV, | | AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-08-07 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-08-07 |
Time |
13:56 |
Sent To |
|
|
Notes |
2015-08-07 15:28:18 | PLEASE SEE ENGINEERING DEVELOPMENT APPLICATION | | E15080021 FOR COMMENTS FROM THE CITY?S PUBLIC WORKS | | DEPARTMENT (WORK WITHIN THE CITY?S RIGHT-OF-WAYS AND | | EASEMENTS, POTABLE WATER SYSTEM, SANITARY SEWER SYSTEM, | | STORMWATER SYSTEM, SOLID WASTE COLLECTION, OR | | PEDESTRIAN AND VEHICULAR TRAFFIC). | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2015-07-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-07-16 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-07-16 |
Time |
14:00 |
Sent To |
|
|
Notes |
2015-07-16 14:02:11 | PUBLIC WORKS DEPT. | | | | 1. AS MENTIONED DURING PPRC REVIEW, ENGINEERING | | DEVELOPMENT APPROVAL IS REQUIRED FOR THIS PROJECT. | | ENGINEERING DEVELOPMENT APPROVAL FROM THE CITY?S PUBLIC | | WORKS DEPARTMENT IS REQUIRED FOR ALL PROJECTS INVOLVING | | OR AFFECTING THE CITY?S STREET RIGHT-OF-WAYS, | | EASEMENTS, POTABLE WATER SYSTEM, SANITARY SEWER SYSTEM, | | STORMWATER SYSTEM, SOLID WASTE COLLECTION, OR | | PEDESTRIAN AND VEHICULAR TRAFFIC. THIS INCLUDES ANY | | WORK THAT INCREASES IMPERVIOUS AREAS; CHANGES THE | | DIRECTION, VELOCITY, OR TIMING OF STORMWATER DISCHARGE; | | OR CREATES A CONDITION OF ENVIRONMENTAL CONCERN. THE | | ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS CAN | | BE DOWNLOADED AT | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | PLEASE SUBMIT AN APPLICATION FOR ENGINEERING | | DEVELOPMENT APPROVAL AND MAKE A NOTE ON THE CIVIL PLANS | | INCLUDED IN THE BUILDING APPLICATION SUBMITTAL THAT | | THEY ARE FOR REFERENCE ONLY. | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2015-04-15 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-04-15 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-04-15 |
Time |
08:47 |
Sent To |
|
|
Notes |
2015-04-15 09:57:20 | PUBLIC WORKS DEPT. | | | | 1. AS MENTIONED DURING PPRC REVIEW, ENGINEERING | | DEVELOPMENT APPROVAL IS REQUIRED FOR THIS PROJECT. | | ENGINEERING DEVELOPMENT APPROVAL FROM THE CITY?S PUBLIC | | WORKS DEPARTMENT IS REQUIRED FOR ALL PROJECTS INVOLVING | | OR AFFECTING THE CITY?S STREET RIGHT-OF-WAYS, | | EASEMENTS, POTABLE WATER SYSTEM, SANITARY SEWER SYSTEM, | | STORMWATER SYSTEM, SOLID WASTE COLLECTION, OR | | PEDESTRIAN AND VEHICULAR TRAFFIC. THIS INCLUDES ANY | | WORK THAT INCREASES IMPERVIOUS AREAS; CHANGES THE | | DIRECTION, VELOCITY, OR TIMING OF STORMWATER DISCHARGE; | | OR CREATES A CONDITION OF ENVIRONMENTAL CONCERN. THE | | ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS CAN | | BE DOWNLOADED AT | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | PLEASE SUBMIT AN APPLICATION FOR ENGINEERING | | DEVELOPMENT APPROVAL AND MAKE A NOTE ON THE CIVIL PLANS | | INCLUDED IN THE BUILDING APPLICATION SUBMITTAL THAT | | THEY ARE FOR REFERENCE ONLY. | | | | | | 2. PLEASE SUBMIT A COPY OF THE APPROVED SITE PLAN | | (Z14120012). WHEN SITE PLAN REVIEW IS REQUIRED, REVIEW | | AND APPROVAL ARE NECESSARY PRIOR TO ISSUANCE OF A | | BUILDING PERMIT. [SECTION 94-35(G) OF THE CITY'S CODE | | OF ORDINANCES] | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2015-09-09 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-09-09 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-09-09 |
Time |
11:06 |
Sent To |
|
|
Notes |
2015-09-09 11:13:06 | 4920 LORING DRIVE | | PERMIT #14120909 | | REVIEW COMMENTS - FIRE DEPARTMENT | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | ****APPROVED WITH PROVISIONS**** | | | | | | 2ND REVIEW | | SHEET G101: NO EXIT SIGNAGE PROVIDED FOR CORRIDOR | | ADJACENT TO CONFERENCE #112. | | | | SHEET G101: PROVIDE ADDITIONAL EXIT SIGN AT EAST END OF | | CORRIDOR #146A. ALSO DOOR APPEARS TO SERVE 51 PERSONS | | SO THE SWING WOULD NEED TO BE WITH THE FLOW OF TRAFFIC | | AND BE EQUIPPED WITH PANIC HARDWARE. | | | | REPEAT COMMENT -SHEET G001: UPDATE THE CODE LIST TO | | REFERENCE THE 5TH EDITION OF THE FLORIDA FIRE | | PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF BOTH | | NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. | | | | SHEET A101 DOES NOT APPEAR TO BE UPDATED TO MATCH THE | | LIFE SAFETY PLAN. | | | | NOTE: THE COOKING GRILL LOCATED ON THE POOL DECK SHALL | | COMPLY WITH NFPA 96 OR SHALL BE LOCATED AT LEAST 10 | | FEET FROM ANY BUILDING, STRUCTURE, OR COMBUSTIBLES PER | | NFPA 1 SECTION 10.11.6.1. IF THE GRILL WILL BE USED | | UNDER A ROOF STRUCTURE, THE DESIGN SHALL COMPLY WITH | | NFPA 96. | | | | | | | | PHASE 2 - FIRE DEPARTMENT REVIEW | | | | REPEAT COMMENT - SHEET G001: UPDATE THE CODE LIST TO | | REFERENCE THE 5TH EDITION OF THE FLORIDA FIRE | | PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF BOTH | | NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. PER | | SECTION 6.1.14.1.2, WHERE EXIT ACCESS FROM AN OCCUPANCY | | TRAVERSES ANOTHER OCCUPANCY, THE MULTIPLE OCCUPANCY | | SHALL BE TREATED AS A MIXED OCCUPANCY. | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-08-26 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-08-07 |
Time |
12:03 |
Sent To |
|
|
Notes |
2015-08-07 12:04:18 | 4920 LORING DRIVE | | PERMIT #14120909 | | REVIEW COMMENTS - FIRE DEPARTMENT | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | | | 2ND REVIEW | | SHEET G101: NO EXIT SIGNAGE PROVIDED FOR CORRIDOR | | ADJACENT TO CONFERENCE #112. | | | | SHEET G101: PROVIDE ADDITIONAL EXIT SIGN AT EAST END OF | | CORRIDOR #146A. ALSO DOOR APPEARS TO SERVE 51 PERSONS | | SO THE SWING WOULD NEED TO BE WITH THE FLOW OF TRAFFIC | | AND BE EQUIPPED WITH PANIC HARDWARE. | | | | REPEAT COMMENT -SHEET G001: UPDATE THE CODE LIST TO | | REFERENCE THE 5TH EDITION OF THE FLORIDA FIRE | | PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF BOTH | | NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. | | | | SHEET A101 DOES NOT APPEAR TO BE UPDATED TO MATCH THE | | LIFE SAFETY PLAN. | | | | NOTE: THE COOKING GRILL LOCATED ON THE POOL DECK SHALL | | COMPLY WITH NFPA 96 OR SHALL BE LOCATED AT LEAST 10 | | FEET FROM ANY BUILDING, STRUCTURE, OR COMBUSTIBLES PER | | NFPA 1 SECTION 10.11.6.1. IF THE GRILL WILL BE USED | | UNDER A ROOF STRUCTURE, THE DESIGN SHALL COMPLY WITH | | NFPA 96. | | | | REPEAT COMMENT - SHEET FP402: FIRE PUMP SCHEDULE DOES | | NOT INDICATE A RATED PRESSURE OR HORSEPOWER RATING. THE | | ENGINEERING DOCUMENTS WILL BE REQUIRED TO DETERMINE IF | | PRESSURE REDUCING VALVES ARE NEEDED ON THE STANDPIPES | | AND SPRINKLER SYSTEMS. PRESSURE REDUCING VALVES WILL | | ALSO REQUIRE A 3-INCH DRAIN RISER IN LIEU OF A 2-INCH | | DRAIN RISER AS SHOWN ON THE PLANS. | | | | REPEAT COMMENT - SHEET FP402: PER FBC SECTION403.3.2 | | WATER SUPPLY TO REQUIRED FIRE PUMPS - REQUIRED FIRE | | PUMPS SHALL BE SUPPLIED BY CONNECTIONS TO A MINIMUM OF | | TWO WATER MAINS LOCATED IN DIFFERENT STREETS. SEPARATE | | SUPPLY PIPING SHALL BE PROVIDED BETWEEN EACH CONNECTION | | TO THE WATER MAIN AND THE PUMPS. EACH CONNECTION AND | | THE SUPPLY PIPING BETWEEN THE CONNECTION AND THE PUMPS | | SHALL BE SIZED TO SUPPLY THE FLOW AND PRESSURE REQUIRED | | FOR THE PUMPS TO OPERATE. | | | | | | PHASE 2 - FIRE DEPARTMENT REVIEW | | | | REPEAT COMMENT - SHEET G001: UPDATE THE CODE LIST TO | | REFERENCE THE 5TH EDITION OF THE FLORIDA FIRE | | PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF BOTH | | NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. PER | | SECTION 6.1.14.1.2, WHERE EXIT ACCESS FROM AN OCCUPANCY | | TRAVERSES ANOTHER OCCUPANCY, THE MULTIPLE OCCUPANCY | | SHALL BE TREATED AS A MIXED OCCUPANCY. | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-04-01 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-04-01 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-03-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
2015-03-13 13:52:38 | 4920 LORING DRIVE | | PERMIT #14120909 | | REVIEW COMMENTS - FIRE DEPARTMENT | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | GENERAL: INDICATE THE LOCATION AND SIZES OF ANY | | PROPOSED CONSTRUCTION TRAILERS/MODULAR BUILDINGS. PER | | NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | JURISDICTION. | | | | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | SHEET G001: UPDATE THE CODE LIST TO REFERENCE THE 5TH | | EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | CONTAINS THE 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 | | WITH FLORIDA AMENDMENTS. PER SECTION 6.1.14.1.2, WHERE | | EXIT ACCESS FROM AN OCCUPANCY TRAVERSES ANOTHER | | OCCUPANCY, THE MULTIPLE OCCUPANCY SHALL BE TREATED AS A | | MIXED OCCUPANCY. | | | | SHEET G101: FIRE COMMAND CENTER (#182B) SHALL BE AT | | LEAST 200 SQUARE FEET AND HAVE A MINIMUM DIMENSION OF | | 10 FEET (FBC 911.1.3). PER NFPA 1 SECTION 11.9.2 THE | | EMERGENCY COMMAND CENTER SHALL BE SEPARATED FROM THE | | REMAINDER OF THE BUILDING BY A FIRE BARRIER HAVING A | | FIRE RESISTANCE RATING OF NOT LESS THAN 1 HOUR. | | PER NFPA 1 SECTION 11.9.4 THE FOLLOWING SHALL BE | | PROVIDED IN THE EMERGENCY COMMAND CENTER: | | (1) THE FIRE DEPARTMENT COMMUNICATION UNIT | | (2) A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | (3) SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | FLOOR PLAN AND DETAILING THE BUILDING CORE MEANS OF | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | EQUIPMENT, AND FIRE DEPARTMENT ACCESS | | (4) WORK TABLE | | (5) IF APPLICABLE, HAZARDOUS MATERIAL MANAGEMENT PLANS | | FOR THE BUILDING | | | | PER NFPA 1 SECTION 11.9.5 WHERE OTHERWISE REQUIRED, THE | | FOLLOWING DEVICES OR FUNCTIONS SHALL BE PROVIDED WITHIN | | THE EMERGENCY COMMAND CENTER: | | (1) THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM UNIT | | (2) FIRE DETECTION AND ALARM SYSTEM ANNUNCIATOR UNIT | | (3) ANNUNCIATOR VISUALLY INDICATING THE LOCATION OF THE | | ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | (4) STATUS INDICATORS AND CONTROLS FOR AIR-HANDLING | | SYSTEMS | | (5) CONTROLS FOR UNLOCKING STAIRWAY DOORS | | SIMULTANEOUSLY | | (6) SPRINKLER VALVE AND WATERFLOW DETECTOR DISPLAY | | PANELS | | (7) EMERGENCY AND STANDBY POWER STATUS INDICATORS | | (8) FIRE PUMP STATUS INDICATORS | | (9) GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | TRANSFER FEATURES | | (10) PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | BY OTHER SECTIONS OF THIS CODE | | (11) CONTROLS REQUIRED FOR SMOKE CONTROL | | | | 11.9.6 EMERGENCY COMMAND CENTER ACCEPTANCE TESTING. | | DEVICES, EQUIPMENT, COMPONENTS, AND SEQUENCES SHALL BE | | INDIVIDUALLY TESTED IN ACCORDANCE WITH APPROPRIATE | | STANDARDS AND MANUFACTURERS? DOCUMENTED INSTRUCTIONS. | | | | SHEET G101: PER TABLE 7.3.1.2, KITCHEN SPACES SHALL | | HAVE AN OCCUPANT LOAD FACTOR OF 100 SQUARE FEET PER | | PERSON IN LIEU OF THE 200 SQ.FT. INDICATED. | | | | SHEET G101: PROVIDE AN OCCUPANT LOAD FOR BREAKROOM | | #167. | | | | SHEET G101: LIBRARY #121, FITNESS #143, AEROBICS #145 | | AND CONFERENCE #112 ARE TREATED AS ASSEMBLY USE SPACES | | IN THE FIRE CODE AND NEED AN OCCUPANT LOAD BASED UPON | | THE OCCUPANT LOAD FACTORS FOUND IN TABLE 7.3.1.2. | | | | ***SHEET G101: SEVERAL EXITS APPEAR TO ROUTE AND MERGE | | EXITING OCCUPANTS AT THE POOL DECK AREA. THERE DOES NOT | | APPEAR EXTERIOR EXIT SIGNAGE, EMERGENCY LIGHTING OR | | SUFFICIENT EXIT WIDTH (1 EGRESS GATE) TO HANDLE THE | | OCCUPANT LOAD. WHERE IS THE PUBLIC WAY? HOW WILL THE | | POOL DECK EGRESS ROUTES BE MAINTAINED UNOBSTRUCTED FOR | | THE LIFE OF THE BUILDING? | | | | SHEET G101: CORRIDOR #146A CREATES A DEAD-END THAT | | EXCEEDS 20 FEET. PER SECTION12.2.5.1.3 DEAD-END | | CORRIDORS SHALL NOT EXCEED 20 FEET. | | | | SHEET C103 &C106: SOUTH ACCESS ROAD INDICATES A 20 FOOT | | WIDE FIRE LANE AT THE POOL GATE; HOWEVER, THE SOUTHWEST | | AREA INDICATES EXISTING ROADS THAT DO NOT APPEAR TO BE | | 20 FEET WIDE AND MARKED AS A FIRE LANE. PER SECTION | | 18.2.3.4.1.1 (NFPA 1), FIRE DEPARTMENT ACCESS ROADS | | SHALL HAVE A SURFACE DESIGNED TO ACCOMMODATE FIRE | | APPARATUS WEIGHING AT LEAST 36 TONS. ACCESS ROADS SHALL | | HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND | | AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13 | | FEET 6 INCHES. PER SECTION 18.2.3.5.3 (NFPA 1), FIRE | | LANES SHALL BE MARKED WITH FREESTANDING SIGNS READING, | | "FIRE LANE - NO PARKING BY ORDER OF THE FIRE | | DEPARTMENT." SIGNS SHALL BE 12" X 18" WITH A WHITE | | BACKGROUND AND RED LETTERS AND SHALL BE A MAXIMUM OF | | SEVEN FEET IN HEIGHT TO THE BOTTOM OF THE SIGN. SIGNS | | SHALL BE WITHIN SIGHT OF THE TRAFFIC FLOW AND BE SPACED | | A MAXIMUM OF 60 FEET APART. | | | | SHEET C107: FIRE HYDRANTS SHALL BE INSTALLED, | | INSPECTED, TESTED AND APPROVED BY THE FIRE DEPARTMENT | | PRIOR TO VERTICAL CONSTRUCTION.PER SECTION 18.3.4.1 | | (NFPA 1), FIRE HYDRANTS SHALL BE PROVIDED WITH | | CLEARANCES OF 7'-6" TO THE FRONT AND SIDES AND 4'-0" TO | | THE BACKSIDE OF THE STEAMER CAP. | | | | SHEET C107: NORTHWEST PIV - PER NFPA 24 SECTION 6.2.1, | | ALL CONNECTIONS TO PRIVATE FIRE SERVICE MAINS FOR FIRE | | PROTECTION SYSTEMS SHALL BE ARRANGED IN ACCORDANCE WITH | | ONE OF THE FOLLOWING SO THAT THEY CAN BE ISOLATED: | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | INDICATOR VALVE. | | (2) A WALL POST INDICATOR VALVE | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | ACCORDANCE WITH SECTION 6.4 | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | THE WALL FACING THE BACKFLOW PREVENTER. | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | ACCESSIBLE FROM THE EXTERIOR | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | AUTHORITY HAVING JURISDICTION | | | | SHEET C107: PER FBC SECTION403.3.2 WATER SUPPLY TO | | REQUIRED FIRE PUMPS - REQUIRED FIRE PUMPS SHALL BE | | SUPPLIED BY CONNECTIONS TO A MINIMUM OF TWO WATER MAINS | | LOCATED IN DIFFERENT STREETS. SEPARATE SUPPLY PIPING | | SHALL BE PROVIDED BETWEEN EACH CONNECTION TO THE WATER | | MAIN AND THE PUMPS. EACH CONNECTION AND THE SUPPLY | | PIPING BETWEEN THE CONNECTION AND THE PUMPS SHALL BE | | SIZED TO SUPPLY THE FLOW AND PRESSURE REQUIRED FOR THE | | PUMPS TO OPERATE. | | | | SHEET A101: CHILLER #182 HAS A DOOR LEADING INTO THE | | FIRE RATED STAIR ENCLOSURE. PER SECTION 7.1.3.2.1 DOORS | | INTO EXIT ENCLOSURES ARE ONLY PERMITTED FOR NORMALLY | | OCCUPIED ROOMS. | | | | SHEET A101C: THE COOKING GRILL LOCATED ON THE POOL DECK | | SHALL COMPLY WITH NFPA 96 OR SHALL BE LOCATED AT LEAST | | 10 FEET FROM ANY BUILDING, STRUCTURE, OR COMBUSTIBLES | | PER NFPA 1 SECTION 10.11.6.1. IF THE GRILL WILL BE USED | | UNDER A ROOF STRUCTURE, THE DESIGN SHALL COMPLY WITH | | NFPA 96. | | | | SHEET A101D: PLANS SHOW OCCUPANTS USING CORRIDOR #185 | | AS A MEANS OF EXIT ACCESS; HOWEVER, BOTH SIDES OF THE | | DOOR APPEAR TO BE ACCOMODATING MORE THAN 50 PERSONS AND | | WOULD NEED TO SWING IN BOTH DIRECTIONS OF EGRESS. | | | | SHEET A102B: TRASH ROOM #205C WALL ADJACENT TO | | RESIDENTIAL ROOM DOES NOT APPEAR TO BE FIRE RATED. | | TYPICAL ALL LEVELS. | | | | SHEET A490: PER SECTION 7.2.2.5.4 - STAIRWAY | | IDENTIFICATION: NEW ENCLOSED STAIRS SERVING THREE OR | | MORE STORIES AND EXISTING ENCLOSED STAIRS SERVING FIVE | | OR MORE STORIES SHALL COMPLY WITH (A) THROUGH (L). | | (A) THE STAIRS SHALL BE PROVIDED WITH SPECIAL SIGNAGE | | WITHIN THE ENCLOSURE AT EACH FLOOR LANDING. | | (B) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL. | | (C) THE SIGNAGE SHALL INDICATE THE TERMINUS OF THE TOP | | AND BOTTOM OF THE STAIR ENCLOSURE. | | (D) THE SIGNAGE SHALL INDICATE THE IDENTIFICATION OF | | THE STAIR ENCLOSURE. | | (E) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL OF, AND | | THE DIRECTION TO, EXIT DISCHARGE. | | (F) THE SIGNAGE SHALL BE LOCATED INSIDE THE ENCLOSURE | | APPROXIMATELY 60-INCHES ABOVE THE FLOOR LANDING IN A | | POSITION THAT IS VISIBLE WHEN THE DOOR IS IN THE OPEN | | OR CLOSED POSITION. | | (G) THE FLOOR LEVEL DESIGNATION SHALL ALSO BE TACTILE. | | (H) THE SIGNAGE SHALL BE PAINTED OR STENCILED ON THE | | WALL OR ON A SEPARATE SIGN SECURELY ATTACHED TO THE | | WALL. | | (I) THE STAIRWAY IDENTIFICATION LETTER SHALL BE LOCATED | | AT THE TOP OF THE SIGN IN MINIMUM 1-INCH HIGH | | LETTERING. | | (J) SIGNAGE THAT READS "NO ROOF ACCESS" AND IS LOCATED | | UNDER THE STAIRWAY IDENTIFICATION LETTER SHALL | | DESIGNATE STAIRWAYS THAT DO NOT PROVIDE ROOF ACCESS. | | LETTERING SHALL BE A MINIMUM OF 1-INCH HIGH. | | (K) THE FLOOR LEVEL NUMBER SHALL BE LOCATED IN THE | | MIDDLE OF THE SIGN IN MINIMUM 5-INCH HIGH NUMBERS. | | MEZZANINE LEVELS SHALL HAVE THE LETTER "M" OR OTHER | | APPROPRIATE IDENTIFICATION LETTER PRECEDING THE FLOOR | | NUMBER, WHILE BASEMENT LEVELS SHALL HAVE THE LETTER "B" | | OR OTHER APPROPRIATE IDENTIFICATION LETTER PRECEDING | | THE FLOOR LEVEL NUMBER. | | (L) IDENTIFICATION OF THE LOWER AND UPPER TERMINUS OF | | THE STAIRWAY SHALL BE LOCATED AT THE BOTTOM OF THE SIGN | | IN MINIMUM 1-INCH HIGH LETTERS OR NUMBERS. | | | | SHEET FP001: ALL NFPA STANDARDS REFERENCES SHALL BE | | UPDATED TO REFLECT THOSE ADOPTED IN THE 5TH EDITION OF | | FLORIDA FIRE PREVENTION CODE EFFECTIVE DECEMBER 31, | | 2014. FOR EXAMPLE. THE SPRINKLER AND STANDPIPE DESIGNS | | SHALL CONFORM TO THE 2010 EDITION OF NFPA 13 AND NFPA | | 14 RESPECTIVELY. | | | | STANDPIPE DESIGN: PROVIDE 2-1/2" OUTLETS ONLY. REMOVE | | THE 1-1/2" REDUCING COUPLINGS ON ALL FIRE DEPARTMENT | | VALVES. | | | | SHEET FP201B: TRASH ROOM #105C IS MISSING THE | | DESIGNATION FOR ORDINARY HAZARD SPRINKLER PROTECTION. | | TYPICAL ALL FLOORS. | | | | SHEET FP402: ENGINEERING DOCUMENTS ARE REQUIRED TO | | INDICATE THE WATER SUPPLY RESULTS FROM A CURRENT | | HYDRANT FLOW TEST. FIRE PUMP SCHEDULE DOES NOT INDICATE | | A RATED PRESSURE OR HORSEPOWER RATING. THE ENGINEERING | | DOCUMENTS WILL BE REQUIRED TO DETERMINE IF PRESSURE | | REDUCING VALVES ARE NEEDED ON THE STANDPIPES AND | | SPRINKLER SYSTEMS. PRESSURE REDUCING VALVES WILL ALSO | | REQUIRE A 3-INCH DRAIN RISER IN LIEU OF A 2-INCH DRAIN | | RISER AS SHOWN ON THE PLANS. | | | | SHEET FP402: PER FBC SECTION403.3.2 WATER SUPPLY TO | | REQUIRED FIRE PUMPS - REQUIRED FIRE PUMPS SHALL BE | | SUPPLIED BY CONNECTIONS TO A MINIMUM OF TWO WATER MAINS | | LOCATED IN DIFFERENT STREETS. SEPARATE SUPPLY PIPING | | SHALL BE PROVIDED BETWEEN EACH CONNECTION TO THE WATER | | MAIN AND THE PUMPS. EACH CONNECTION AND THE SUPPLY | | PIPING BETWEEN THE CONNECTION AND THE PUMPS SHALL BE | | SIZED TO SUPPLY THE FLOW AND PRESSURE REQUIRED FOR THE | | PUMPS TO OPERATE. | | | | | | SHEET M201B: ALL HVAC KEY NOTES APPEAR TO BE MISLABLED. | | | | | | | | | | | | | | PHASE 2 - FIRE DEPARTMENT REVIEW | | | | SHEET G001: UPDATE THE CODE LIST TO REFERENCE THE 5TH | | EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | CONTAINS THE 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 | | WITH FLORIDA AMENDMENTS. PER SECTION 6.1.14.1.2, WHERE | | EXIT ACCESS FROM AN OCCUPANCY TRAVERSES ANOTHER | | OCCUPANCY, THE MULTIPLE OCCUPANCY SHALL BE TREATED AS A | | MIXED OCCUPANCY. | | | | SHEET G101: THE FIRE RATING FOR STAIR #4 DOES NOT | | CONTINUE TO THE EXTERIOR WALLS OR DOORS. PER SECTION | | 7.2.2.5.2.1 WHERE NONRATED WALLS OR UNPROTECTED | | OPENINGS ENCLOSE THE EXTERIOR OF A STAIRWAY AND THE | | WALLS OR OPENINGS ARE EXPOSED BY OTHER PARTS OF THE | | BUILDING AT AN ANGLE OF LESS THAN 180 DEGREES, THE | | BUILDING ENCLOSURE WALLS WITHIN 10 FEET HORIZONTALLY OF | | THE NONRATED WALL OR UNPROTECTED OPENING SHALL BE | | CONSTRUCTED AS REQUIRED FOR STAIRWAY ENCLOSURES, | | INCLUDING OPENING PROTECTIVES. PER SECTION 7.2.2.5.2.2 | | CONSTRUCTION SHALL EXTEND VERTICALLY FROM THE FINISHED | | GROUND LEVEL TO A POINT 10 FEET ABOVE THE TOPMOST | | LANDING OF THE STAIRS OR TO THE ROOFLINE, WHICHEVER IS | | LOWER. | | | | SHEET L101: SOUTH ACCESS ROAD INDICATES A 20 FOOT WIDE | | FIRE LANE AT THE POOL GATE; HOWEVER, THE SOUTHWEST AREA | | INDICATES EXISTING ROADS THAT DO NOT APPEAR TO BE 20 | | FEET WIDE AND MARKED AS A FIRE LANE. PER SECTION | | 18.2.3.4.1.1 (NFPA 1), FIRE DEPARTMENT ACCESS ROADS | | SHALL HAVE A SURFACE DESIGNED TO ACCOMMODATE FIRE | | APPARATUS WEIGHING AT LEAST 36 TONS. ACCESS ROADS SHALL | | HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND | | AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13 | | FEET 6 INCHES. PER SECTION 18.2.3.5.3 (NFPA 1), FIRE | | LANES SHALL BE MARKED WITH FREESTANDING SIGNS READING, | | "FIRE LANE - NO PARKING BY ORDER OF THE FIRE | | DEPARTMENT." SIGNS SHALL BE 12" X 18" WITH A WHITE | | BACKGROUND AND RED LETTERS AND SHALL BE A MAXIMUM OF | | SEVEN FEET IN HEIGHT TO THE BOTTOM OF THE SIGN. SIGNS | | SHALL BE WITHIN SIGHT OF THE TRAFFIC FLOW AND BE SPACED | | A MAXIMUM OF 60 FEET APART. | | | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2016-03-17 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-03 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-03 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-09-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-09-09 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-09-08 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-09-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-07-14 |
Time |
11:02 |
Sent To |
|
|
Notes |
2015-07-28 16:27:15 | CLOSED DUE TO MORE PLANS BEING UPLOADED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-06-23 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-03-06 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-01-28 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-01-05 |
Time |
14:29 |
Sent To |
|
|
Notes |
2015-08-03 09:55:04 | 1/28/15 APPLICANT HAS CHOSEN TO END THE REVIEW CYCLE | | AND RESUBMIT FULL PLANS AND CHANGE PERMIT TYPE, PERMIT | | DESCRIPTION, AND PAY ADDITIONAL FEES UPON RE-SUBMITTAL. | | SAK |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-29 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-29 |
Time |
18:03 |
Sent To |
|
|
Notes |
2015-07-29 18:03:47 | IMPACT FEES FOR PHASE I & II | | | | MU 2015 016915 0000 | | MU 2015 016916 0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2015-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-05 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-05 |
Time |
16:47 |
Sent To |
|
|
Notes |
2015-05-05 16:47:52 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | THIS CAN BE DONE AT ANY TIME DURING THE PLAN REVIEW | | PROCESS BUT MUST BE COMPLETED AND SUBMITTED FOR REVIEW | | PRIOR TO PERMIT ISSUANCE. | | | | SAMANTHA HILL | | 561-805-6724 | | [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-01-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-01-10 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-01-10 |
Time |
13:05 |
Sent To |
|
|
Notes |
2015-01-10 13:06:39 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-09-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-08-28 |
Time |
09:10 |
Sent To |
|
|
Notes |
2015-09-02 14:50:11 | PASS REVISION REQUIRED | | 1) PROVIDE ACCESS FOR VAV 2-7, 2-8 AND 2-9 ON PAGE | | M201.B | | 2) PUT ALL MECHANICAL PLANS TOGETHER TO MAKE PLAN | | REVIEW LESS CONFUSING | | 3) COULD NOT FIND ENERGY CALCULATIONS,COME TO FIND | | SUPPORTING DOCS HAD OVER | | 300 PAGES. PLEASE INDEX SUPPORTING DOCS. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-06-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-06-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-05-26 |
Time |
11:30 |
Sent To |
|
|
Notes |
2015-06-01 09:51:37 | PLAN DENIED | | 1) PROVIDE ENERGY CALCULATIONS WITH THE | | PLANS. PER SECTION 503.2.1 CALCULATIONS | | OF HEATING AND COOLING LOADS. 2010 | | FLORIDA ENERGY CODE. | | 2) PROVIDE FRESH AIR CALCULATIONS ON PLAN | | PER TABLE 403.3 FBC (M) 2010 | | 3) DRYER BOOSTER FANS ARE NOT PERMITTED | | IN THE CITY OF WEST PALM BEACH PER WPB. | | FIRE DEPARTMENT. | | 4) MISSING FIRE DAMPERS ON 1ST FLOOR | | REFER TO SECTION 607 FBC (M) 2010 | | 5) PROVIDE NOA ON ALL OUTSIDE GRILLS | | PER SECTION 107.3.4.1 GENERAL 2010 FBC. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2015-09-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-03 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-03 |
Time |
11:46 |
Sent To |
|
|
Notes |
2015-09-03 11:49:30 | PLUMBING PASSED WITH PROVISOS. SEE PLAN REVIEW COMMENTS | | DATED 8/17/15. ALL PLUMBING PLAN REVIEW CORRECTIONS | | SHALL BE SUBMITTED WITHIN 60 DAYS OF IISUANCE OF MAIN | | PERMIT. T. LARGE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2015-08-17 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-08-17 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-08-08 |
Time |
06:41 |
Sent To |
|
|
Notes |
2015-08-12 06:42:50 | 1) SHT.063-AS109 - DETAIL #1 - THE MAXIMUM HEIGHT OF | | THE SINK CABINET SHALL BE 36 INCHES PER THE FAIR | | HOUSING ACT CFR 100.205 (C) (1).ONE OF THE SINKS SHALL | | HAVE A 30 INCH WIDE BY 48 INCH LONG CLEAR FLOOR SPACE | | CENTERED ON THE FIXTURE. SHOW THE REQUIRED CLEAR FLOOR | | SPACE ON THE PLAN. THE RESPONSE NARRATIVE WHICH REFERS | | TO FBC-A SEC. 233.3.1 EXCEPTION IS NOT APPLICABLE. | | (COMMENT # 6). | | 2) SHT. 262-P.003 - THE PLAN STILL SHOWS A GENERATOR | | BUT THE RESPONSE NARRATIVE STATES THE GENERATOR HAS | | BEEN REMOVED FROM THE PERMIT SET. CLARIFY.(SEE PREVIOUS | | REVIEW COMMENT #9). | | 3) SHT.074-A101 - THE SINK IN THE ART STUDIO #124 AND | | BREAK ROOM (#167) SHALL COMPLY WITH THE FAIR HOUSING | | ACT CFR 100.205 (C) (1).THE SINKS SHALL HAVE A MAXIMUM | | HEIGHT OF 36 INCHES AND SHALL HAVE A CLEAR FLOOR SPACE | | OF 30" X 48" CENTERED ON THE FIXTURE. SHOW THE REQUIRED | | CLEAR FLOOR SPACES ON THE PLAN. THE RESPONSE NARRATIVE | | WHICH REFERS TO FBC-A SEC. 233.3.1 EXCEPTION IS NOT | | APPLICABLE. (COMMENT#10) . | | 4) SHT. 146- A400 - SHOW THE MINIMUM AND MAXIMUM HEIGHT | | DIMENSIONS FOR THE LOCATION OF THE REINFORCEMENT FOR | | THE GRAB BARS. 2ND REQUEST. COMPLY WITH CFR 100.205 (6) | | & ANSI A117.1. (SEE PREVIOUS REVIEW COMMENT #11). | | 5) CLARIFY THE RESPONSE NARRATIVE TO MY PREVIOUS REVIEW | | COMMENT #14. THIS PROJECT CLEARLY FALLS UNDER THE FAIR | | HOUSING ACT YET THE RESPONSE FROM PERKINS EASTMAN | | STATES THE A OR B DESIGN SPECIFICATION IS NOT REQUIRED | | SINCE THE PROJECT MEETS FBC-A 233.3.1, EXCEPTION. | | 6) SHT. 168-A451 - DETAIL # 10-MEN'S & WOMEN'S | | RESTROOMS - BOTH OF THE AMBULATORY STALLS SHALL HAVE | | GRAB BARS ON NOTH SIDES OF THE STALL PER 2010 | | FBC-ACCESS. SEC.604.8.2.3. | | 7) SHT. 169-A452 -DETAIL # 020 - THERE ARE NO DETAILS | | FOR THE SEAT IN THE SHOWER IN THE ACCESSIBLE CHANGING | | ROOM. THE SEAT SHALL COMPLY WITH ANSI A117.1 -1986 | | SEC.4.24. | | 8) SHT. 185-A510 - DETAIL # 2 - SHOW THE REQUIRE KNEE & | | TOE CLEARANCES FOR THE SINK PER ANSI A117.1 - 1986. | | 9) SHT. 153-403(A) -DETAIL #2 - SHOW THE REQUIRED 30 | | INCHES BY 48 INCHES CLEAR FLOOR SPACE REQUIRED FOR THE | | SHOWER PER THE FHA GUDELINES AND CFR 100.205. | | 10) SHOW THE DEPTH OF THE TYPICAL LAVATORY IN THE | | LIVING UNITS. THE LAVATORIES SHALL NOT EXCEED 24 INCHES | | IN DEPTH PER THE FHA GUIDELINES. | | 11) SHT. 148-A401B - DETAIL # 1A - SHOW THE DISTANCE | | BETWEEN THE CABINETS . COMPLY WITH THE FHA GUIDELINES | | REQUIREMENT #7 AND CFR 100.205.ALSO, SEE DETAIL #1. | | 12) SHT.144-A352 - DETAIL # 9 - CLEARLY IDENTIFY THE | | SCUPPER ON THE DETAIL AND SHOW THE SCUPPER OPENING. | | SCUPPERS SHALL NOT HAVE AN OPENING DIMENSION LESS THAN | | 4 INCHES PER 2010 FBC-SEC.1107.3. | | 13) PLAN REVIEW COMMENT #24 - THE RESPONSE NARRATIVE | | REFERS TO DRAWINGS # FS-2E & FS-3E. THERE ARE NO SUCH | | DRAWINGS IN THIS PLAN SET. CLARIFY. | | 14) WHY ARE PLANS FOR "EDWARD'S PAVILLION" INCLUDED | | WITH THESE PLANS? | | 15) SHT. 2075 -A407 IS NUMBERED AS A PHASE II DRAWING | | IN THE NAMING CONVENTION BUT THE PLAN IS LISTED AS | | BEING IN PHASE I ON THE PLAN ITSELF. CLARIFY.REFER TO | | LOWER RIGHT HAND CORNING OF DRAWING. SHT. 2129-P4.02 | | WHICH ARE THE RISERS FOR THIS AREA IS NOTED AS PHASE | | II. WHICH IS IT? | | 16) SHT.2128-P4.01 - ONE OF THE RISERS IS MISSING ITS | | IDENTIFYING NUMBER. | | 17) PLAN REVIEW COMMENT # 35 - SHT. 2126-P201B & 2130- | | P403 - IDENTIFY THE OTHER TWO WATER MAINS AND PROVIDE | | THE PAGE NUMBER FOR THE CONTINUATION POINT.WPB AMEND. | | TO FBC SEC. 107.2.1. THE RESPONSE NARRATIVE REFERS TO | | REVISED SHEETS P001 & P403. THESE SHEETS HAVE NOT BEEN | | REVISED & P003 IS A PLUMBING SITE PLAN. CLARIFY. 2ND | | REQUEST. | | 18) PLAN REVIEW COMMENT # 37 - EXPLAIN HOW HALF OF UNIT | | A1C CAN BE LOCATED IN PHASE I AND THE OTHER HALF IN | | PHASE II. THE RESPONSE NARRATIVE NOTES THAT THE ROOM | | NAME HAS BEEN CHANGED TO "STORAGE". THIS HAS NOT BEEN | | DONE. IT IS STILL A LIVING UNIT. CLARIFY. | | 19) PLAN REVIEW COMMENT # 39 - SHT.2135-P501 - SHOW THE | | SIZE OF THE COPPER DWV LINE FROM THE WASHING MACHINE. | | THE MINIMUM SIZE SHALL BE 2". THE RESPONSE NARRATIVE | | NOTES THAT THE DETAIL HAS BEEN REMOVED FROM THE SHEET | | BUT IN FACT IT HAS NOT. NOTHING HAS BEEN DONE TO THE | | SHEET IN THE SET. CLARIFY. | | 20) PLAN REVIEW COMMENT # 2131-P404 - THE SIZE OF THE | | WATER RISERS DO NOT MATCH FROM THE 9TH TO THE 10TH | | FLOOR. I ASSUME THE LINES ARE BEING REDUCED BECAUSE OF | | THE NUMBER OF FIXTURES AT THE 10TH FLOOR. THE RESPONSE | | NARRATIVE REFERS TO REVISED SHT.P404 BUT THERE IS NO | | REVISED SHEET IN THE SET. REFER TO RISERS # | | 24,26,27,29,30 & 31. ALSO , THERE ARE NO PIPE SIZES ON | | THE RISERS ON WATER RISER #24 AT THE TENTH FLOOR | | LEVEL.CLARIFY. | | 21) PLAN REVIEW COMMENT # 41 - SHT. 2131-P404 - WATER | | RISER #28 IS NOT SHOWN ON THE PLAN.THE RESPONSE | | NARRATIVE NOTES " SEE REVISED SHEET P404. THERE IS NO | | REVISED SHEET P404 IN THE SET. CLARIFY. | | 22) PLAN REVIEW COMMENT # 53 - SHT.261-P002 - SUBMIT | | MANUFACTURER'S SPECIFICATION SHEETS FOR THE ELEVATOR | | SUMP PUMP. COMPLY WITH 2010 FBC-PLUMBING SEC.1003.4 - | | EXCEPTION. THE RESPONSE NARRATIVE NOTES "SEE REVISED | | SHEET P002. THERE IS NO REVISED SHEET P002. CLARIFY. | | 23) PLAN REVIEW COMMENT # 55 - SHT.262-P003 - PLUMBING | | KEYNOTE #3 STATES THAT THE COOLING TOWER WATER TO | | DISCHARGE TO THE SANITARY. COOLING WATER CANNOT | | DISCARGE TO THE SANITARY PER CWPB ORD. SECTION 90-126 | | (5). COOLING TOWER WATER SHALL NOT DRAIN TO THE | | STORMWATER SYSTEM PER CITY ORD. SEC.90-203. THE NOTE IS | | STILL ON THE PLAN. CLARIFY. | | 24) PLAN REVIEW COMMENT # 56 - SHT. 299- P501 SHOW THE | | SIZE OF THE INTERCEPTORS AS 1500 GALS. THE MAXIMUM SIZE | | OF AN INDIVIDUAL GREASE INTERCEPTOR CHAMBER SHALL BE | | 1250 GALS. PER 2010 FBC-PLUMBING SEC.1003.5.1.WHEN THE | | CAPACITY IS GREATER THAN 1250 GALLONS, MULTI-CHAMBERED | | GREASE INTERCEPTORS OR GREASE INTERCEPTORS IS SERIES | | SHALL BE REQUIRED. | | 25) PLAN REVIEW COMMENT #69 - INDICATE ON THE STORM | | RISER PLANS OR ON SHEETS 275-P105 & 276-P106 THAT THE | | DESIGN OF THE STORM DRAINAGE SYSTEM INCLUDES 1/2 THE | | AREA OF ANY VERTICAL WALLS THAT DIVERTS RAINWATER TO | | THE ROOF. THE DESIGN SHALL ALSO INCLUDE THE SQUARE | | FOOTAGE OF ANY SLOPED ROOF THAT DIVERTS RAINWATER TO | | THE FLAT ROOFS.2010 FBC-PLUMBING SEC.1106.4. | | 26) SHT. 268-P101C - THE NOTES AT THE GREASE TRAP ARE | | DIFFICULT TO READ. THERE IS OTHER TEXT OVER TOP OF | | IT.PLEASE CORRECT, WPB AMEND. TO FBC SEC. 107.2.1. | | 27) SHT.299-P501 - SHOW THE PIPE SIZES OF ALL SECTIONS | | OF PIPE FOR THE DOMESTIC BOOSTER WATER PUMP,WATER | | SOFTENER AND PRESSURE REDUCING STATION. WPB AMEND. TO | | FBC SEC. 107.2.1. | | 28) SHT. 280-P301 - THE SANITARY AND WATER RISERS FOR | | UNIT A1C ARE MISSING THE IDENTIFYING NUMBERS. | | 29) SHT.297-P412 - SHOW THE DISTANCE IN DEVELOPED | | LENGTH FROM EACH LINE PRESSURE REGULATOR TO THE MOST | | REMOTE OUTLET AND THE LOAD OF THE SECTION.SHOW THE | | LENGTHS OF EACH SECTION OF PIPE FOR THE 2 PSI SYSTEM | | AND THE LESS THAN 2 PSI SYSTEM. 2010 FBC-FUEL GAS SEC. | | 402.4.1, NFPA 54 SEC.6.1.3. | | 30) SHT.297-P412 - THE GAS RISER IS SHOWING 4,996 CFH | | ON A 1 1/4" LINE AT 2 PSI. THE SIZING TABLE REFERENCED | | ON THE DRAWING ALLOWS A MAXIMUM OF 1,470 CFH AT 2 PSI | | ON AN 1 1/4" LINE. IT APPEARS THE LINE IS SEVERELY | | UNDERSIZED.THE MINIMUM SIZE SHALL BE 2 1/2 INCHES. | | 31) SHT. 297-P412 - THE BTU LOAD AT POINT D ON THE | | DRAWING DOES NOT EQUAL THE SUM OF THE BTU'S OF THE | | LISTED FIXTURES. CLARIFY. | | 32) SHOW THE BRANCH LINES TO THE POOL AND KITCHEN AREA | | ON THE GAS RISER DIAGRAM AND SIZE THE LINE AND SUPPLY | | THE BTU LOAD FOR THE BRANCH LINES.WPB AMEND. TO FBC | | SEC. 107.3.5.1. | | 33) THE SIZE OF THE GAS LINE TO THE FIREPLACE MAY | | BEREQUIRED TO BE A MINIMUM OF 3/4" PER TABLE 6.2 (A) OF | | NFPA 54. | | 34) THE CFH AT THE METER SHOW 5020.3 CFH BUT THE CFH ON | | THE 1 1/4" LINE DOWNSTREAM OF THE METER SHOWS 4,996 | | CFH, WHERE DID THE ADDITIONAL LOAD AT THE METER COME | | FROM? CLARIFY. | | 35) PLEASE EXPLAIN THE NOTATION OF "8 OZ." ON THE GAS | | DRAWING. | | 36) THE PRV 'S SHALL COMPLY WITH THE FBC- FUEL GAS | | SEC.410.2 (4),(5), (6),& 410.3. | | 37)THE LINE FROM THE METER TO POINT "B" SHALL BE A | | MINIMUM OF 2 1/2 INCHES PER NFPA 54 TABLE 6.2 (C). | | 38) LIST THE CORRECT APPLICABLE GAS SIZING TABLES FOR | | EACH TYPE OF MATERIAL BEING USED . WPB AMEND. TO FBC | | SEC. 107.3.5.1.3. | | 39) THE BTU LOAD DOWNSTREAM OF OF POINT "D" APPEARS | | INCORRECT. ADDING THE 1,996 CFH FROM THE POOL AND | | KITCHEN AREA TO THE BTU LOAD COMES TO 3,310.3. RE-CHECK | | YOUR CALCULATIONS.(SEE AREA AT 2020.3 CFH). CHECK THE | | ENTIRE SYSTEM FOR CORRECT SIZING. | | 40 ) THE BTU LOAD UPSTREAM OF POINT "D" SHOULD BE | | 6310.3.I CALCULATE THE ENTIRE BTU LOAD ON THE SYSTEM AS | | 7610.3 CFH. CLARIFY. | | 41) PVC IS NOT PERRMITED TO BE USED TO VENT REGULATORS | | INDOORS PER FBC-FUEL GAS SEC.403.6.3. | | 42.) SHT. 297-P412 - SHOWS THE GAS PIPING BEING | | INSTALLED UNDER THE SLAB. THIS METHOD IS PERMITTTED IF | | THERE IS NO OTHER METHOD TO INSTALL THE PIPING. IF THE | | PIPING CAN BE RUN OVERHEAD THAT IT HOW IT SHALL BE | | INSTALLED. IF THERE IS NO OTHER METHOD, THE | | INSTALLATION SHALL COMPLY WITH 2010 FBC-FUEL GAS | | SEC.404.12.1 OR 404.12.2. THE VENT TO THE ROOF IS NOT | | AN ACCEPTED METHOD. | | 43) THE PLAN SHOWS PE PIPE IN THE CONDUIT. PLASTIC PIPE | | SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY PER | | FBC-FUEL GAS SEC.404.15.1. | | 44) PLAN REVIEW COMMENT # 77 - SHT. 297-412 - SUBMIT | | CALCULATIONS FOR COMBUSTION AIR IN ACCORDANCE WITH 2010 | | FBC-FUEL GAS SEC. 304. SUBMIT DETAILS ON THE | | LOCATION/TERMINATION AND TYPES OF GAS VENTS, HEIGHT | | ABOVE THE ROOF, ETC.THE RESPNSE NARRATIVE REFERS TO | | DRAWINGS M206, M503 & M505. THERE ARE NO SUCH DETAILS | | ON M206 AND I COULD NOT FIND A SHEET LABELED M505. | | CLARIFY. | | 45) IT APPEARS THAT CALCULATIONS FOR COMBUSTION AIR FOR | | THE GAS SYSTEM HAVE NOT BEEN SUBMITTED. I COULD NOT | | FIND THE CALCULATIONS ON ANY PLANS. CLARIFY. | | 46) SHT.332-M504 - DETAIL #3 REFERS TO DETAIL #6 ON | | SHT. 327-M404. THERE IS NO SUCH DETAIL. CLARIFY. | | 47) SUBMIT VENT DETAILS FOR THE POOL HEATERS . WPB | | AMEND. TO FBC SEC. 107.3.5.1.3. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-18 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-11 |
Time |
12:06 |
Sent To |
|
|
Notes |
2015-05-06 10:24:23 | 1) THIS BUILDING IS CLASSIFIED AS AN R-2 OCCUPANCY ON | | SHT. G001 (001) AND IS EQUIPPED WITH AN ELEVATOR | | THEREFORE ALL THE RESIDENTIAL UNITS ON ALL THE FLOORS | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FEDERAL FAIR | | HOUSING ACT AND SEC. 233 OF THE 2010 FL. ACCESSIBILITY | | CODE.UNDER THE HEADING "FBC 2010 ACCESSIBILITY | | ACCESSIBLE UNITS" THERE IS A REFERENCE TO CODE SECTION | | 11-9.1.4. THERE IS NO SUCH CODE SECTION IN THE 2010 | | FBC.HOW ARE YOU ARRIVING TO THE FACT THAT ONLY 5% OF | | THE UNITS HAVE TO COMPLY WITH HANDICAP REQUIREMENTS? | | CALRIFY. | | 2) THE APPLICATION SUBMITTED WITH THESE PLANS STATE | | "FOUNDATION ONLY" YET THE PLANS ARE FULL SETS FOR PHASE | | I & PHASE II. THE APPLICATION DOES NOT STATE IF THE | | FOUNDATION PLAN IS FOR BOTH PHASES OR JUST ONE. | | CLARIFY. | | 3) SHT.G101 - CLARIFY HOW YOU ARRIVED AT THE REQD. | | FIXTURES FOR THE GROUP A-1, A-2, A-3 OCCUPANCIES. I | | CAME UP WITH SLIGHTLY DIFFERENT DECIMAL EQUIVQLENTS. | | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 4)SHT.G101 - DEFINE THE ASTERISKS ON THE PLUMBING | | FIXTURE TABLE. I DO NOT SEE ANY FOOTNOTES. CLARIFY. | | 5) SHT. AS 106 - THE WATER SUPPLY FOR THE FOUNTAIN | | SHALL BE EQUIPPED WITH A BACKFLOW PREVENTION DEVICE PER | | 2010 FPC SEC.608.1. | | 6) SHT. AS 109 ( DETAIL #1 ) THE SINK SHALL COMPLY | | W/THE FAIR HOUSING ACT FOR ACCESSIBLE AND USABLE PUBLIC | | AND COMMON USE AREAS PER CFR 100.205. | | 7) SHT. AS 106 - THE WATER SUPPLY FOR THE FOUNTAIN | | SHALL BE EQUIPPED WITH A BACKFLOW PREVENTION DEVICE PER | | 2010 FPC SEC.608.1. | | 8) SHT. AS109 - FLOOR DRAINS ARE SHOWN IN THE POOL | | SERVICE AREA. INDICATE IF THEY ARE CONNECTED TO THE | | STORM OR SANITARY SYSTEM. | | 9) SUBMIT COMPLETE DETAILS FOR THE EMERGENCY GENERATOR. | | SUBMIT MANUFACTURER'S SPECS, FUEL AND FUEL PIPING | | DETAILS,GENERATOR EXHAUST, ETC. WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 10) THE SINK IN THE ART STUDIO #124 ANF THE BREAK ROOM | | SINK #167 SHALL COMPLY W/THE FAIR HOUSING ACT FOR | | ACCESSIBLE AND USABLE PUBLIC AND COMMON USE AREAS PER | | CFR 100.205. | | 11) SHT. A-400 SHOW THE LENGTH AND WIDTH DIMENSIONS OF | | THE REINFORCING FOR THE GRAB BARS FOR THE SHOWERS, | | TUBS, & WATER CLOSETS. ALSO, SHOW THE MINIMUM AND | | MAXIMUM HEIGHT DIMENSIONS FOR THE LOCATION OF | | REINFORCEMENT. COMPLY WITH CFR 100.205 (6) & ANSI | | A117.1. | | 12) SHT. A401B - SHOW THE CLEAR INSIDE DIMENSIONS (L X | | W) OF THE SHOWER. A 30 X 48 INCH CLEAR FLOOR SPACE | | SHALL BE PROVIDED AT SHOWER STALLS, PARALLEL TO THE | | FIXTURE AND FLUSH WITH THE CONTROL WALL. | | 13) SHT. A403 SHOW THE HEIGHTS OF THE CABINETS, GRAB | | BARS, ETC. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 14) INDICATE ON THE PLANS THE DESIGN SPECIFICATION (A | | OR B) BEING USED FOR THE DESIGN OF THE USABLE BATHROOMS | | .SPECIFICATION A APPLIES TO ALL BATHROOMS IN THE | | COVERED DWELLING UNIT AND ALL FIXTURES IN THOSE | | BATHROOMS MUST BE USABLE . SPECIFICATION B APPLIES TO | | ONE BATHROOM AND ONLY ONE OF EACH TYPE OF FIXTURE MUST | | BE USABLE; ADDITIONAL BATHROOMS IN THE UNIT ARE EXEMPT | | ONLY FROM MANEUVERING AND CLEAR FLOOR SPACE AT | | FIXTURES. | | 15) SHT. A451 SHOW THE LENGTH OF THE AMBULATORY TOILET | | STALLS IN THE MEN'S & WOMEN'S RESTROOMS. COMPLY WITH | | THE 2010 FAC SEC. 604.8.2.1. DOORS SHALL NOT SWING INTO | | THE MINIMUM REQUIRED COMPARTMENT AREA PER SEC. | | 604.8.2./ANSI A117.1. | | 16) SHT. A452 GRAB BARS ARE REQUIRED IN THE ACCESSIBLE | | SHOWER IN THE ACCESSIBLE CHANGING ROOM. FAC SEC. 608.3 | | & 609.4. A SEAT SHALL ALSO BE PROVIDED PER FAC | | SEC.608.4. | | 17) SHT.A452 THE ACCESSIBLE CHANGING ROOM IS LISTED AS | | #149 ON THE PLAN VIEW IN DETAIL #014 AND AS #142 & 143 | | ON THE ELEVATION DETAILS. IS THIS A TYPO? CLARIFY. | | 18) SHT. A506 INDICATE ON THE PLAN IF THE FIREPLACE IS | | WOOD OR GAS BURNING. IF GAS, SUBMIT MANUF. | | SPECIFICATIONS FOR THE UNIT AND SHOW IT ON THE GAS | | RISER. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 19) SHT.A510 DETAIL #2 SHOW THE REQUIRED CLEARANCES FOR | | THE ACCESSIBLE LAVATORY PER THE FAC SEC.306. | | 20) PLACE THE PLANS IN ORDER AS THEY ARE LISTED IN THE | | INDEX SHEET. TIME IS WASTED SEARCHING FOR THE LOCATION | | OF PLANS. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 21) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL THE | | GAS EQUIPMENT & APPLIANCES. APPLIANCES & EQUIPMENT | | SHALL BE LISTED PER THE 2010 FBC-FUEL GAS CODE SEC. | | 301.3. MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ALL | | APPLIANCES/EQUIPMENT SHALL BE ON THE JOBSITE PER 2010 | | FBC-FUEL GAS CODE SEC.305.1. | | 22) FOOD SERVICE DRAWINGS. SUBMIT MANUFACTURING | | SPECIFICATIONS FOR ALL GAS EQUIPMENT. EQUIPMENT SHALL | | BE LISTED AND LABELED PER FBC-FUEL GAS SEC. 301.3. | | 23) FOOD SERVICE EQUIPMENT SHALL BE NSF APPROVED .2010 | | FBC-PLUMBING SEC.409. | | 24) SHT. FS-4 - PLUMBING CONNECTION DETAILS FOR ITEMS # | | 36,38,140. THERE IS NO LEGEND FOR THE ITEM #140 ON THE | | FS DRAWINGS. CLARIFY. | | 25) SHT. P105 (2-125) PHASE II THE PLAN SHOWS A 4" | | RAINWATER LEADER (RL 13) WITH 1535 SQ. FEET DRAINING | | INTO IT. THE MAXIMUM SQUARE FOOTAGE IS 1504 PER | | FBC-PLUMBING TABLE 1106.3.SEE DRAIN NEAR GRIDLINE | | G/2.8. | | 26) PROVIDE A SCUPPER DETAIL. SCUPPERS SHALL NOT HAVE | | AN OPENING DIMENSION LESS THAN 4 INCHES. 2010- FBC- | | PLUMBING SEC. 1107.3. SCUPPERS SHALL COMPLY WITH 2010 | | FBC SEC. 1503.4.2.1. | | 27) SHT.P100B (2-120) DOES NOT CORRELATE WITH THE | | SANITARY RISER ON SHT. P401 (2-128) AS TO THE LAYOUT. | | BRANCHES ARE SHOWN ON P100B THAT ARE NOT ON P401. ALSO | | SANITARY RISER #33 DOES NOT APPEAR TO CONNECT TO THE | | BUILDING DRAIN. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 28) SHT.P401 (2-128) THERE ARE NO CONTINUATION POINTS | | SHOWN FOR THE STACK VENTS OR BRANCH VENTS. CLARIFY. I | | HAVE IDENTIFIED THESE AREAS WITH A MARKUP. | | 29) SHT. P100B (2-120) THERE IS A CD RISER & A SANITARY | | RISER THAT IS NOT NUMBERED. CLARIFY.IT HAS BEEN | | IDENTIFIED THEM WITH A MARKUP. WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 30) SHT.P101B (2-121) ROOM #133.THERE IS A CD RISER | | THAT IS NOT NUMBERED.CLARIFY. IT HAS BEEN IDENTIFIED | | WITH A MARKUP. | | 31) SHT. P102B (2-122) THERE IS A SANITARY RISER THAT | | IS NOT IDENTIFIED BY A NUMBER. SEE GRIDLINE F/4.2. IT | | IS IDENTIFIED WITH A MARKUP. CLARIFY. THIS OCCURS ON | | ALL LEVELS. | | 31) SHT. P402 (2-129) WHERE IS SANITARY RISER #31? | | CLARIFY. | | 32) SHT. P402 (2-129) SANITARY RISER #29 WC-1 APPEARS | | TO BE DRAINING INTO A 2 INCH LINE. IT APPEARS AS THOUGH | | WC-1 MAY BE MISLABELED. IF IT IS A WATER CLOSET THEN | | THE 3 " VENT STACK NEEDS TO BE INCREASED TO 4 INCHES | | PER 2010 FPC TABLE 916.1. CLARIFY. | | 33) SHT. P402 (2-129) SANITARY RISER #29 DOES NOT | | COMPLY WITH FPC 2010 SEC. 909.1 FOR THE TYPE OF | | FIXTURES PERMITTED ON A HORIZONTAL WET VENT. ALSO, SIZE | | THE HORIZONTAL DRAIN BETWEEN WC-1 AND OB-1 ON THE | | RISER. | | 34) SHT. P402 (2-129) SANITARY RISERS #28 AND #31 ARE | | NOT SHOWN ON THE PLAN. CLARIFY. | | 35) SHT. P403 (2-130) & P201B (2-126) IDENTIFY THE | | OTHER TWO WATER MAINS AND PROVIDE PAGE NUMBER FOR | | CONTINUATION POINT. PROVIDE IDENTIFICATION LEGEND FOR | | THE MAINS. WPB AMEND. TO 2010 FBC SEC. 107.2.1., | | 107.3.5.1.3. | | 36) SHT. P201B (2-126) OB-1 AND WC-1 (UNIT D2 # 102) - | | THE SYMBOL IS SHOWN ON THE PLAN VIEW BUT THERE IS NO | | WATER PIPING SHOWN TO THE FIXTURE. CLARIFY. | | 37) SHT. P301 (2-127) - EXPLAIN HOW HALF OF UNIT A1C | | CAN BE LOCATED IN PHASE I AND THE OTHER HALF IN PHASE | | II. WHAT OCCURS IF BOTH PHASES ARE NOT BUILT AT THE | | SAME TIME? | | 38) IT IS EXTREMELY DIFFICULT TO FIGURE WHICH | | CONDENSATE, SANITARY AND WATER RISER APPLY TO WHICH | | MODEL UNITS. SHOW THE LOCATION AND IDENTIFY THE RISERS | | ON THE ENLARGED FLOOR PLANS FOR THE UNITS. WPB AMEND. | | TO 2010 FBC SEC.107.2.1, 107.3.5.1.3. | | 39) SHT. P501 (2-135) SHOW THE SIZE OF THE COPPER DWV | | LINE FROM THE WASHING MACHINE. THE MIN. SIZE OF THE | | TRAP & STANDPIPE SHALL BE 2" AND SHALL CONNECT TO A | | BRANCH DRAIN OR DRAINAGE STACK THAT IS A MINIMUM OF 3 | | INCHES. FPC SEC.406.3. SEE ALSO SHT. P404. | | 40) SHT. P404 (2-131) THE SIZE OF THE WATER RISERS DO | | NOT MATCH FROM THE 9TH TO THE 10TH FLOOR. REFER TO | | RISESRS # 24, 26, 27,29,30, & 31. CLARIFY. | | 41) SHT. P404 (2-131) WATER RISER #28 IS NOT SHOWN ON | | THE PLAN. CLARIFY. | | 42) 42) SHT.P105 (2-125) SUBMIT DETAILS FOR SECONDARY | | (EMERGENCY) ROOF DRAINAGE PER 2010 FBC-PLUMBING, | | SECS.1107.1, 1107.2, 1107.3 AND 2010 FBC-BUILDING, | | SECS. 1503.4.1, 1503.4.2.1. | | 43) SHT.P405 (2-132) INDICATE THE SLOPE OF ALL THE | | HORIZONTAL STORM DRAIN PIPING. COMPLY WITH 2010 | | FBC-PLUMBING TABLE 1106.3. | | COMMENTS ON THE STORM DRAIN SYSTEM ARE ASSUMING A 1% | | SLOPE ON THE PIPE. | | 44) SHT.P405 (2-132) IF THE SLOPE OF THE PIPE IS 1/8" | | UNIT VERTICAL IN 12 UNITS HORIZONTAL (1% SLOPE), THEN | | THE UNDERGROUND STORM DRAIN DOWNSTREAM OF RL/ 9 MUST BE | | 10", NOT 8". | | 45) SHT.P405 SIZE THE STORM DRAIN DOWNSTREAM OF RL/2. | | 46) SHT. P405 CHECK THE CALCULATIONS FOR THE TOTAL | | SQUARE FOOTAGE BEING DRAINED. MY CALCULATIONS ARRIVE AT | | 32,200 SQ. FT. | | 47) SHT.P407 (2-134) THE CONDENSATE RISER SHOWS 1/2" | | DRAINS FROM THE FAN COIL UNITS. THE MINIMUM SIZE DRAIN | | SHALL BE 3/4" I.D. PER FBC-PLBG., SEC.314.2.2 & TABLE | | 314.2.2. | | 48) SHT.P407 (2-134) IDENTIFY ALL THE CONDENSATE | | RISERS. (U/G, ROOF LEVEL, FAN COIL DETAILS) IT IS | | EXTREMELY DIFFICULT AND TIME CONSUMING TO TRY TO | | DETERMINE WHERE THESE RISERS ARE LOCATED. WPB AMEND. TO | | WPB SEC. 107.3.5.1.3. | | 49) THE CONDENSATE RISERS FOR THE FAN COILS SHOW A 3" | | FLOOR DRAIN DISCHARGING INTO THE RISER. WHAT IS | | DISCHARGING INTO THIS FLOOR DRAIN? | | 50) SHT.P407 (2-134) IDENTIFY THE PIECE OF EQUIPMENT | | SHOWN ON THE PLAN. WPB AMEND. TO 2010 FBC. 107.2.1. | | 51) SHT.P407 (2-134) SHOWS A 4" CONDENSATE DRAIN INTO | | THE SUMP AND A 4" DISCHARGE AND DETAIL #2 SHOWS A 1 " | | DISCHARGE. CLARIFY. | | 52) SHT. P501 (2-135)? SUBMIT MANUFACTURER'S | | SPECIFICATIONS/INSTALL MANUAL FOR THE CONDENSATE WATER | | PUMP PACKAGE STSP-3. WPB AMEND. TO 2010 FBC SEC. | | 107.2.1. SHOW THE DIMENSIONS OF THE SUMP. | | 53) 53) SHT.P002 (261) SUBMIT MANUF. SPECS FOR THE OIL | | SMART SUMP PUMP. WPB AMEND. TO 2010 FBC SEC.107.2.1. | | 54) SHT. P003 (262) - CLEARLY SHOW THE ENTIRE LIMITS OF | | PHASE ONE AND PHASE TWO ON THE PLAN. | | 55) SHT. P003 (262) PLBG. KEYNOTE #3 STATES THE COOLING | | BASIN OVERFLOW TO SANITARY. COOLING TOWER WATER CANNOT | | DRAIN TO THE SANITARY PER CITY ORDINANCE 90-126 (5). | | 56) SHT. P501 (299) THE GREASE TRAP SHALL COMPLY WITH | | 2010 FPC SEC.1003.5.1 & 1003.5.2, 1003.5.3. SUBMIT | | SIZING CALCULATIONS FOR HE INTERCEPTOR IN ACCORDANCE | | WITH 2010 FPC. TABLE 1003.5.1. | | 57) SHT. P501 (299) & SHT. P003 (262) SIZE THE INLET | | AND OUTLET LINE FROM THE INTERCEPTORS. | | 58) SHT.P003 (262) SIZE THE 3 STORM LINES COMING FROM | | THE NEW RESIDENT BUILDING AND SIZE THE CDU LINE. | | 59) SHT. P003 - THE CONDENSATE DISCHARGE LINE IS SHOWN | | AS 2" ON THE CIVIL PLANS AND AS 4". CLARIFY. | | 60) THE COOLING TOWER SHALL COMPLY WITH NFPA 214. | | SUBMIT DETAILS. | | 61) SUBMIT MANUF. SPECS FOR THE PIPE WRAP FOR THE | | UNDERGROUND CONDENSATE PIPE. WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 62) INDICATE ON THE PLAN IF THE GENERATOR IS NEW OR | | EXISTING. IF NEW, SUBMIT SPECIFICATIONS FOR IT. | | 63) SHT. 101C (268) LABEL THE RAINWATER LEADER LOCATED | | IN THE CARTS ROOM #155, THE DINING ROOM AND HOSTESS | | ROOM #157. | | 64) SHT.P102A (269) LABEL THE CD RISER LOCATED IN ROOM | | #237 THAT GOES TO AREA MARKED ?OPEN TO BELOW. | | 65 ) SHT. 205C (102B) LABEL THE CD RISER FROM THE FCU | | IN ROOM NEXT TO TRASH ROOM . | | 66) SHT. P103A (271) IDENTIFY THE CD RISER IN COMMUNITY | | ROOM # 837. LABEL ALL THE CONDENSATE RISERS ON SHTS. | | P102A, P103A, 103B, ETC. | | 67) IDENTIFY ALL THE SHEETS FOR CONTINUATION OF THE | | MATCH LINES. THERE ARE NO REFERENCE SHEET NUMBERS AT | | THE MATCH LINES . | | 68) SUBMIT A LEGEND FOR IDENTIFICATION OF THE WATER | | MAINS AND WHAT THEY ARE. WPB AMEND. TO 2010 FBC SEC. | | 107.2.1. | | 69) ROOF DRAINAGE INDICATE ON THE STORM RISER PLANS | | THAT THE SIZING OF THE STORM DRAINAGE INCLUDES 1/2 OF | | THE SQUARE FOOTAGE OF ANY VERTICAL (PARAPET) WALLS PER | | FBC-PLUMBING, SEC.1106.4. | | 70) SHT. P401A (285) ? THE ISOMETRIC SHOWS A FLAT DRY | | VENT BY SAN. RISER #1. THE SHOWER DOWNSTREAM OF STACK | | S/8 MUST BE LOCATED DOWNSTREAM A MINIMUM OF 10 PIPE | | DIAMETERS OF THE UPPER DRAINAGE STACK. IDENTIFY THE | | PLUMBING FIXTURE DOWNSTREAM OF STACK S/15. SEE ALSO | | FIXTURE S-1 DOWNSTREAM OF STACK S/16. SEE FPC | | SEC.704.3. | | 71) 71) SHT. P402 (287)SAN RISERS #1, #3, & # 6 DO NOT | | COMPLY WITH FPC SEC. 909 FOR ALLOWED FIXTURES ON A | | HORIZONTAL WET VENT. THE WASHING MACHINES AND S-2 ARE | | NOT FIXTURES IN A BATHROOM GROUP AND ARE NOT PERMITTED | | ON A WET VENT. ALSO, THE FIXTURE BT-1 IS NOT VENTED ON | | SAN. RISER #4. | | 72) SHT.P412 (297) SHOWS 3 " GAS DROPS TO THE WATER | | HEATERS AND SHT.502 (300) SHOWS 1 1/4" AND A 2" GAS | | LINE TO THE WATER HEATERS. CLARIFY. | | 73) SHT. P412 SHOWS THE LONGEST RUN AS 400 FT. BUT MY | | CALCULATIONS COME TO 498 FT. CLARIFY. | | 74) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL GAS | | EQUIPMENT. ALL EQUIPMENT/APPLIANCES SHALL BE LISTED AND | | LABELED PER FBC-FUEL GAS SEC. 301.3. | | 75) SHT. P412 NATURAL GAS RISER DIAGRAM - IF THE | | LONGEST RUN IS CONFIRMED AT 498 FT. THEN THE PIPE SIZES | | OF THE FOLLOWING SECTIONS NEED TO BE REVISED AS | | FOLLOWS: PIPE SECTION I-J SHALL BE A MIN. OF 1 ??. | | SECTION H-I SHALL BE 3?. SECTION D-E SHALL BE 5? | | MINIMUM. A MAXIMUM OF 2110 CFH IS ALLOWED ON A 4" LINE | | AT ? PSI PER THE REFERENCED TABLE FROM NFPA. | | 76) SHT. P412 - INSTALLATION OF UNDERGROUND PIPING | | SHALL COMPLY WITH NFPA SEC.7.1.6.2 OR 2010 FBC -FUEL | | GAS, SEC.404.6.2. INDICATE TYPE OF PIPING TO BE USED. | | 77) SUBMIT CALCULATIONS FOR COMBUSTION AIR IN | | ACCORDANCE WITH 2010 FBC - FUEL GAS SEC.304. SUBMIT | | DETAILS ON LOCATION AND TYPES OF VENTS, HEIGHT ABOVE | | ROOF, ETC. | | 78)SHT. P501 - SIZE ALL SECTIONS OF THE PIPING FOR THE | | DOMESTIC BOOSTER WATER PUMP, WATER SOFTENER AND | | PRESSURE REDUCING STATION. WPB AMEND. TO 2010 FBC SEC. | | 107.2.1. | | | | ***PLEASE CONTACT CAROLINE PUELL, PERMIT LIBRARIAN, | | PRIOR TO UPLOADING REVISED PLANS TO ENSURE PROPER | | NAMING CONVENTIONS ORDER.*** | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2015-08-17 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-01-07 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-01-07 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2015-08-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-10 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-10 |
Time |
07:21 |
Sent To |
|
|
Notes |
2015-08-10 07:22:53 | ****PROVISO**** | | ISSUED AT CONTRACTOR?S RISK | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 2010 FLORIDA BUILDING CODE WITH 2012 FBC SUPPLEMENTS | | ADOPTED APRIL 25/2013. | | | | NO ROOF COVERING INFORMATION HAS BEEN SUBMITTED AT THIS | | TIME | | | | ROOF PRODUCT APPROVALS, REVIEWED BY DESIGNER OF RECORD, | | ARE TO BE SUBMITTED WITH ROOF PERMIT APPLICATION PRIOR | | TO INSTALLATION | | | | THE ROOF COVERING ASSEMBLY AT THE CONNECTING CORRIDOR | | IS TO HAVE A CLASS B RATING (PER SHEET G101, PER FBC | | 706.6 EXCEPTION 3) | | | | ALL ROOFS TO MEET THE FOLLOWING DESIGN PRESSURES PER | | SHEET S8.5: | | | | ZONE 1 +52.0 / -76.4 | | ZONE 2 +76.4 / -119.9 | | ZONE 3 +52.0 / -119.9 | | | | | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-06 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-06 |
Time |
15:14 |
Sent To |
|
|
Notes |
2015-05-06 15:15:32 | ****PROVISO**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | [email protected] | | | | 1. NO ROOF PRODUCT APPROVALS SUBMITTED. | | | | PRIOR TO INSTALLATION, ROOF PRODUCT APPROVALS ARE TO BE | | SUBMITTED FOR REVIEW. DESIGNER OF RECORD IS TO REVIEW | | THE PRODUCT APPROVALS AND ENGINEERING (IF APPLICABLE) | | PRIOR TO SUBMITTAL. | | | | NOTES: | | | | DESIGN PRESSURES ON SHEET S8.5 | | FLAT METAL DECK | | WOOD DECK (PITCHED) | | | | | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-01-08 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-01-07 |
Time |
14:23 |
Sent To |
|
|
Notes |
2016-01-22 07:14:42 | THE PLANS DO NOT MATCH THE ISSUED PERMIT. FOR INSTANCE, | | SEE THE FOLLOWING SHEETS: | | | | PHASE II, VOLUME II: | | | | FP 301, FP302 PROJECT DOX VERSION IS DATED 11/6/14, | | PAPER PLAN IS DATED 2/13/15. | | | | THE SIGNATURE DOCUMENTS ARE TO BE CONSISTENT WITH THE | | PERMIT ISSUED DOCUMENTS. | | | | | | | 2016-01-07 14:24:06 | GIVEN TO SHILL TO VERIFY |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2015-09-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-23 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-23 |
Time |
13:07 |
Sent To |
|
|
Notes |
2015-09-23 17:00:40 | THE PAPER PLAN SET WAS SUBMITTED ONLY FOR THE PURPOSE | | OF PROVIDING SIGNATURE AND SEALS FOR ALL DESIGN | | PROFESSIONALS. | | | | ANOTHER CONSOLIDATED SIGNATURE AND SEAL FOR THE PERMIT | | PLANS WILL BE REQUIRED. CONTRACTOR WILL BE ADVISED OF | | THE PROCESS VIA EMAIL. | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
3 |
Status |
P |
Date |
2015-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-05 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-05 |
Time |
08:05 |
Sent To |
|
|
Notes |
2015-08-05 08:06:08 | CONTRACTOR WAS GIVEN ONE SET ON 8/5/15 | | ONE SET ROUTED TO RECORDS (SCANNING) | | ONE SET ROUTED TO KEN CONRAD'S DESK | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-27 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-27 |
Time |
09:54 |
Sent To |
|
|
Notes |
2015-07-27 09:54:27 | ****CORRECTIONS**** | | 14120908, 14120909 | | THRESHOLD INSPECTION PLAN, SPECIAL INSPECTOR AGREEMENT | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THRESHOLD INSPECTION PLAN, ITEM 6.02 B AND C REFER | | TO OPENINGS IN THE FIRST 60 FEET. FBC 1609.1.2(2), | | PLEASE REVISE TO COMPLY WITH THIS SECTION (ALL OPENINGS | | REQUIRED TO HAVE IMPACT PROTECTION). | | | | 2. THE SPECIAL INSPECTOR AGREEMENT IS LACKING THE | | SIGNATURE OF THE DESIGNER OF RECORD, PAGE 5 OF 6 (THIS | | SHOULD BE SIGNED AND SEALED). | | | | PLEASE REMOVE THE OLD SHEETS AND REPLACE WITH THE NEW | | SHEETS. | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-18 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-18 |
Time |
13:20 |
Sent To |
|
|
Notes |
2015-05-18 13:21:13 | SPECIAL INSPECTOR AGREEMENT AND RESUMES FOR CONTRACTOR | | AND INSPECTORS REQUIRED | | SEE BUILDING COMMENTS | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2015-09-04 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-09-04 |
Time |
16:18 |
Rev Time |
5.00 |
Received By |
eschneid |
Date |
2015-09-04 |
Time |
16:18 |
Sent To |
|
|
Notes |
2015-09-04 16:33:05 | PASSED W/PROVISOS | | | | 1) ALL ELEVATIONS, SECTIONS, ROOF PLANS AND DETAIL | | SHEETS SHALL BE REVISED TO ACCURATELY REFLECT THE LOWER | | BUILDING HEIGHT TO MEET THE REQUIREMENTS OF RESOLUTION | | NO. 49-13. THE BACK-UP MATERIAL SHOWS THE SLOPED TOWER | | ROOF MEETING THIS REQUIREMENT, BUT THERE SEEM TO BE | | SOME OF THE AREAS SURROUNDED BY PARAPETS THAT MAY | | EXCEED THE HEIGHT. | | | | 2) THE RETAINING WALL UNDER PERMIT 15090033. ALL PLANS | | SHALL BE REVISED TO MATCH THE APPROVED RETAINING WALL. | | CURRENTLY THERE ARE A NUMBER OF DIFFERENT | | CONFIGURATIONS SHOWN. | | | | 3) THE SITE PLANS SHOW A DIFFERENT ORIENTATION FOR THE | | BICYCLE RACK AND AREA BETWEEN THE BUILDINGS THAN THE | | ZONING APPROVED PLANS. THE CHANGES SHALL BE REFLECTED | | ON THE REVISED SITE PLANS AND ON A MINOR PD AMENDMENT. | | PLEASE NOTE THAT MORSELIFE CURRENTLY HAS A MINOR PD | | AMENDMENT UNDER REVIEW THAT COULD BE MODIFIED TO | | INCLUDE THE CHANGES. | | | | 4) SHEET G101 SHOWS NOTE REFERENCING A 17 FOOT CLEAR | | FIRE TRUCK ACCESS ROAD (SOUTH OF POOL WALL). THE | | APPROVED SITE PLAN SHOWS THIS AS A 20 FOOT WIDE | | DRIVEWAY. PLEASE CORRECT SHEET G101. THIS CHANGE IS | | ALSO SHOWN ON SHEET L101. THIS SHALL BE INCLUDED ON THE | | PLAN REVISIONS. | | | | 5) SHEET C101 SHOWS THE 20 FOOT FIRE DEPARTMENT ACCESS | | DRIVE ON THE EAST SIDE OF THE BUILDINGS AS NOT INCLUDED | | WITH THE CONSTRUCTION THE INITIAL TOWER. THIS WAS A | | REQUIREMENT OF THE FIRE DEPARTMENT TO SERVICE THE | | BUILDING AND THUS SHALL BE PROVIDED FOR IN PHASE 1. | | | | 6) SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE | | FOLLOWING: | | | | A. LANDSCAPE - PLEASE NOTE THAT THE ROW OR PARKING TO | | THE NORTH OF THE 20 FOOT FIRE DEPARTMENT ACCESS AREA | | SHALL BE TERMINATED BY THE REQUIRED TREE IN PHASE 1. | | B. IRRIGATION | | C. TEMPORARY CONSTRUCTION ACCESS DRIVE - NOTE: A TREE | | ALTERATION PERMIT IS REQUIRED PRIOR TO THE APPROVAL OF | | THE TEMPORARY ACCESS DRIVE TREE REMOVAL. | | D. PARKING LOT PAVING AND STRIPING | | E. BICYCLE RACK | | F. COMPACTOR ENCLOSURE | | G. POOL, SPA AND FOUNTAIN | | H. FENCES AND GATES | | I. GENERATOR BUILDING | | J. SITE LIGHTING | | K. COOLING TOWER AREA | | | | 7) NOTE: THE FUTURE TRACT LINE DOES NOT MATCH UP WITH | | THE DOORWAY AS SHOWN ON SHEET L101. THE FUTURE TRACT | | LINE SHALL NOT CUT THROUGH THE CORRIDOR AT AN | | UNPROTECTED POINT. | | | | 8) PLEASE REMEMBER THE DEADLINE FOR THE PLAT APPROVAL | | APPROVED BY ROBERT BROWN, BUILDING OFFICIAL. | | | | 9) PLEASE NOTE THAT THE TRADITIONS PHASE II SHALL HAVE | | MET THE COMMENCEMENT OF DEVELOPMENT DATE OF NOVEMBER 3, | | 2015, IN ACCORDANCE WITH ITS FINAL EXTENSION. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-08-07 |
Time |
11:00 |
Rev Time |
8.00 |
Received By |
eschneid |
Date |
2015-08-07 |
Time |
11:00 |
Sent To |
|
|
Notes |
2015-08-07 11:02:12 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSE TO COMMENTS. | | | | 1) THE BUILDING APPEARS TO BE TALLER THAN THE 110 FEET | | PERMITTED BY THE TRADITIONS PHASE II APPROVALS | | (ORIGINALLY ORD. NO. 4110-08, CURRENT RES. NO. 49-13). | | THE WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS STATE, "...THE HEIGHT SHALL BE MEASURED AS | | THE VERTICAL DISTANCE FROM THE AVERAGE ELEVATION OF THE | | FINISHED GRADE OF THE BUILDING TO THE HIGHEST POINT OF | | THE TOP OF THE STRUCTURE OF A FLAT ROOF...". SECTION | | 94-306 ALLOWS CERTAIN HEIGHT EXCEPTIONS AS FOLLOWS: | | "HEATING, VENTILATION, AND AIR CONDITIONING EQUIPMENT; | | CHURCH STEEPLES, BELL TOWERS, FLAG POLES, CHIMNEYS, | | PARAPETS, STAIR ENCLOSURES, TANKS, DECORATIVE FEATURES, | | ELEVATOR HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO | | ANTENNAS, AND RELATED MECHANICAL OR FUNCTIONAL FEATURES | | MAY EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN | | PERCENT." THE ELEVATION DRAWINGS SHALL BE AMENDED TO | | INCLUDE THE FOLLOWING DIMENSION LINES: | | | | A. THE BASE MEASURE SHALL BE FROM THE AVERAGE ELEVATION | | OF THE FINISHED GRADE OF THE BUILDING. IT APPEARS THAT | | THE ELEVATIONS PROVIDED ARE USING FINISHED FLOOR OR TOP | | OF THE SLAB. THE STRUCTURAL DRAWINGS INDICATE THAT THE | | FOUR (4) INCH SLAB IS ON GRADE, NOT AT GRADE, WHICH | | WOULD MAKE IT FOUR (4) INCHES HIGHER THAN THE AVERAGE | | ELEVATION OF THE FINISHED GRADE (THIS IS ALSO INDICATED | | ON THE BUILDING SECTION DRAWINGS). PLEASE CLARIFY. | | B. EXTEND THE DIMENSION LINE TO THE HIGHEST POINT OF | | THE BUILDING. STAFF HAS SCALED THE DRAWING AND IT | | APPEARS THAT THE HIGHEST POINTS ON THE BUILDING ARE 123 | | FEET. SECTION 94-306 ALLOWS THE HEIGHT EXCEPTION FOR | | THIS BUILDING TO EXTEND TO 121 FEET (HEIGHT WAIVER TO | | 110 FEET X 10% = 11 FEET ADDITIONAL HEIGHT EXCEPTION). | | | | 2) PLEASE CLARIFY IF THE RETAINING WALL IS INCLUDED AS | | PART OF THIS PERMIT. THE SITE AND CIVIL PLANS SHOW THE | | MAJORITY OF THE RETAINING WALL AREA AS PART OF THIS | | PERMIT. THE FOUNDATION PLAN SHOWS MOST OF THE WALL NOT | | INCLUDED. PRESUMABLY THE BALANCE OF THE RETAINING WALL | | WOULD BE INCLUDED WITH THE DINING ROOM PERMIT. WHY | | SPLIT UP THE RETAINING WALL AND NOT BUILD IT UNDER ITS | | OWN PERMIT? | | | | 3) THE NEW RETAINING WALL IS SHOWN IN DIFFERENT | | LOCATIONS ON THE PLANS LISTED BELOW. PLEASE EXPLAIN WHY | | DIFFERING WALL LOCATIONS ARE SHOWN. | | | | COTLEUR & HEARING PLANS | | MICHAEL B. SCHORAH & ASSOCIATES, INC. PLANS | | ONM&J PARTIAL FOUNDATION PLANS | | PERKINS EASTMAN ARCHITECTURAL PLANS | | | | 4) THE LANDSCAPE PLANS CALL FOR LITTORAL PLANTING TO | | THE WEST OF THE OVERLOOK PORTION OF THE RETAINING WALL. | | PLEASE EXPLAIN HOW THIS WILL OCCUR GIVEN THE DEPTH AND | | SLOPE THAT ARE BEING PROPOSED. | | | | 5) THE SITE PLANS SHOW A DIFFERENT ORIENTATION FOR THE | | BICYCLE RACK AND AREA BETWEEN THE BUILDINGS THAN THE | | APPROVED PLANS. THE CHANGES SHALL BE REFLECTED ON A | | MINOR PD AMENDMENT. PLEASE NOTE THAT MORSELIFE | | CURRENTLY HAS ONE UNDER REVIEW THAT COULD BE MODIFIED | | TO INCLUDE THE CHANGES. | | | | 6) SHEET G101 SHOWS NOTE REFERENCING A 17 FOOT CLEAR | | FIRE TRUCK ACCESS ROAD (SOUTH OF POOL WALL). THE | | APPROVED SITE PLAN SHOWS THIS AS A 20 FOOT WIDE | | DRIVEWAY. PLEASE CORRECT SHEET G101. THIS CHANGE IS | | ALSO SHOWN ON SHEET L101 | | | | 7) SHEET C101 SHOWS THE 20 FOOT FIRE DEPARTMENT ACCESS | | DRIVE ON THE EAST SIDE OF THE BUILDINGS AS NOT INCLUDED | | WITH THE CONSTRUCTION THE INITIAL TOWER. THIS WAS A | | REQUIREMENT OF THE FIRE DEPARTMENT TO SERVICE THE | | BUILDING AND THUS SHALL BE PROVIDED FOR PHASE 1. | | | | 8) THE PARKING LOT, CONSTRUCTION ACCESS ROADWAY AND | | DRIVE, IRRIGATION, LANDSCAPING, SITE LIGHTING, | | GENERATOR BUILDING, BICYCLE RACKS, COMPACTOR ENCLOSURE, | | COOLING TOWER AREA, AND FENCES/GATES REQUIRE SEPARATE | | PERMIT SUBMITTALS, WITH PLANS. PLEASE DO NOT RESUBMIT | | THESE SHEETS. PLEASE NOTE THAT THE ROW OR PARKING TO | | THE NORTH OF THE 20 FOOT FIRE DEPARTMENT ACCESS AREA | | SHALL BE TERMINATED BY THE REQUIRED TREE IN PHASE 1. | | | | 9) TREE ALTERATION PERMIT IS REQUIRED PRIOR TO THE | | APPROVAL OF THE TEMPORARY ACCESS DRIVE TREE REMOVAL. | | | | 10) NOTE: THE FUTURE TRACT LINE DOES NOT MATCH UP WITH | | THE DOORWAY AS SHOWN ON SHEET L101. THE FUTURE TRACT | | LINE SHALL NOT CUT THROUGH THE CORRIDOR AT AN | | UNPROTECTED POINT. | | | | 11) PLEASE REMEMBER THE DEADLINE FOR THE PLAT APPROVAL | | APPROVED BY ROBERT BROWN, BUILDING OFFICIAL. | | | | 12) PLEASE NOTE THAT THE TRADITIONS PHASE II SHALL HAVE | | MET THE COMMENCEMENT OF DEVELOPMENT DATE OF NOVEMBER 3, | | 2015, IN ACCORDANCE WITH ITS FINAL EXTENSION. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2015-04-02 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-04-02 |
Time |
16:12 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2015-04-02 |
Time |
16:12 |
Sent To |
|
|
Notes |
2015-04-02 16:12:40 | FAILED | | | | 1) THE PROPOSED BUILDING STRADDLES THE CURRENT LOT LINE | | BETWEEN TRACTS B AND C. ORDINANCE NO. 4110-08, WHICH | | ADOPTED THE TRADITIONS PHASE 2 DEVELOPMENT, INCLUDED A | | CONDITION THAT PRIOR TO THE SUBMITTAL OF THE BUILDING | | PERMIT FOR VERTICAL CONSTRUCTION, A UNITY OF TITLE FOR | | TRACTS B AND C HAS TO BE RECORDED. | | | | 2) MORSELIFE HAS SUBMITTED AN APPLICATION TO CHANGE THE | | TRACT BOUNDARIES TO MOVE THE LOT LINES BETWEEN THE | | BUILDINGS; HOWEVER, THIS HAS NOT YET BEEN APPROVED. | | PLEASE BE AWARE THAT THE NEW TRACT LINE LOCATION | | BISECTS THE CORRIDOR CONNECTING THE TWO BUILDINGS, | | WHICH MAY REQUIRE A FIRE RATED DOOR ON THE TRACT LINE. | | | | 3) THE MINOR PLANNED DEVELOPMENT AMENDMENT FOR THE | | REVISED TRADITIONS PHASE 2 HAS NOT RECEIVED FINAL | | APPROVAL FROM THE PLANNING DIVISION. | | | | 4) ZONING CANNOT REVIEW OR APPROVE UNTIL THE ITEMS IN | | 1-3 ABOVE ARE SATISFIED. | | | | 3) LANDSCAPE, PARKING, BICYCLE RACKS, ETC. REQUIRE | | SEPARATE PERMIT WITH PLANS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | 2015-03-10 13:54:17 | 3/10/15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2015-01-28 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-01-28 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-01-28 |
Time |
10:31 |
Sent To |
|
|
Notes |
2015-01-28 10:31:47 | REVIEW CYCLE ENDED AS APPLICANT WILL SUBMIT REDESIGN. |
|
|
|