Plan Review Details - Permit 14120732
Plan Review Stops For Permit 14120732 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-05 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-05 |
Time |
14:09 |
Sent To |
|
|
Notes |
2015-07-05 14:20:02 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | PLAN REVIEW HAS BEEN PASSED WITH REDLINES. | | | | THE INSTALLATION SCHEDULE HAS BEEN REVISED AND THE NOA | | HAS BEEN CIRCLED SO THAT CONTRACTOR CAN SEE WHERE THE | | INFORMATION WAS OBTAINED. IF CONTRACTOR DOES NOT AGREE | | WITH THE CHANGES, PLEASE REVISE THE PRODUCT APPROVAL TO | | INDICATE ANCHORING PROPOSED, REVISE THE INSTALLATION | | SCHEDULE, AND PROVIDE EXPLANATION FOR THE FOLLOWING: | | | | PAGE 10, A DETAIL WITH WOOD SUBSTRATE CIRCLED, BUT IT | | APPEARS THAT WOOD IS NOT A SUBSTRATE FOR ANY OPENINGS. | | INSTALLATION SCHEDULE STATED THAT SUBSTRATE IS | | CONCRETE; MOST CBS STRUCTURES HAVE CONCRETE TOP (FORMED | | AND POURED TIE BEAM OR LINTEL) AND BLOCK BOTTOM | | SUBSTRATES. | | OPENINGS 7 & 8, DUE TO THE SIZE IT APPEARS THAT THEY | | ARE SLIDING GLASS DOORS. THE FLOOR PLAN IS NOT CLEAR. | | THESE TWO OPENINGS ARE LIKELY CONCRETE TOP & BOTTOM, | | BUT I WAS UNABLE TO LOCATE MOUNTING CONNECTION TYPE | | "D2" ON THE PRODUCT APPROVAL (SEE PAGES 4 & 5 - A, B, C | | ONLY). | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-07 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-07 |
Time |
13:08 |
Sent To |
|
|
Notes |
2015-03-07 13:14:51 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. OK | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT: | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | - AWNING, CASEMENT, SINGLE HUNG? | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | WINDOW IS FULLY OPEN. | | | | 3. NEW COMMENT - IT IS NOT POSSIBLE TO DETERMINE | | CORRELATE THE PRODUCT APPROVALS WITH THE OPENINGS. FOR | | INSTANCE: | | | | PRODUCT APPROVAL 14610.5 VINYL HORIZONTAL ROLLER NON | | IMPACT HAS "WINDOW #3" WRITTEN ON IT, BUT OPENING #3 | | DOES NOT HAVE SHUTTERS PROPOSED. | | | | 14610.6 AND 17472.2 ARE IMPACT PRODUCTS, "W-3" WRITTEN | | ON BOTH. | | | | REVISE THE FLOOR PLAN TO INDICATE TYPE OF WINDOW | | PROPOSED (CORRELATE WITH THE PRODUCT APPROVAL), | | INDICATE LOCATION OF THE IMPACT WINDOWS. PROVIDE THE | | SIZES OF ALL OPENIINGS AND THE ADDITIONAL INFORMATION | | REQUIRED FOR BEDROOM WINDOWS AS INDICATED IN ITEM #2. | | | | THE PAGE PROVIDED PREVIOUSLY NO LONGER CORRELATES WITH | | THE NEW FLOOR PLAN AND PRODUCT APPROVALS PROVIDED. FOR | | INSTANCE, OPENING #3 ON THE CHART PROVIDED IN FIRST | | SUBMITTAL STATES THAT FL1850 R9 IS PROPOSED, NOT | | CONSISTENT WITH THE NEW INFORMATION. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-12-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-29 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-12-29 |
Time |
09:19 |
Sent To |
|
|
Notes |
2014-12-29 09:21:07 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FOR THE PROPOSED ACCORDION SHUTTERS, COMPLETE THE | | SAMPLE INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION | | TO SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC | | R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS | | AVAILABLE IN THE LOBBY OR ON THE INTERNET AT | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT: | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | - AWNING, CASEMENT, SINGLE HUNG? | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | WINDOW IS FULLY OPEN. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-05 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-06-15 |
Time |
|
Sent To |
B |
|
Notes |
2015-06-16 11:20:10 | TO S.HILL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-07 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-25 |
Time |
11:45 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-12-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-29 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-12-29 |
Time |
09:21 |
Sent To |
|
|
Notes |
2014-12-22 16:32:24 | ROUTED TO MISC1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |