Plan Review Details - Permit 14120732
Plan Review Stops For Permit 14120732
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-07-05 Cont ID  
Sent By shill Date 2015-07-05 Time 14:20 Rev Time 0.00
Received By shill Date 2015-07-05 Time 14:09 Sent To  
Notes
2015-07-05 14:20:02****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 PLAN REVIEW HAS BEEN PASSED WITH REDLINES.
  
 THE INSTALLATION SCHEDULE HAS BEEN REVISED AND THE NOA
 HAS BEEN CIRCLED SO THAT CONTRACTOR CAN SEE WHERE THE
 INFORMATION WAS OBTAINED. IF CONTRACTOR DOES NOT AGREE
 WITH THE CHANGES, PLEASE REVISE THE PRODUCT APPROVAL TO
 INDICATE ANCHORING PROPOSED, REVISE THE INSTALLATION
 SCHEDULE, AND PROVIDE EXPLANATION FOR THE FOLLOWING:
  
 PAGE 10, A DETAIL WITH WOOD SUBSTRATE CIRCLED, BUT IT
 APPEARS THAT WOOD IS NOT A SUBSTRATE FOR ANY OPENINGS.
 INSTALLATION SCHEDULE STATED THAT SUBSTRATE IS
 CONCRETE; MOST CBS STRUCTURES HAVE CONCRETE TOP (FORMED
 AND POURED TIE BEAM OR LINTEL) AND BLOCK BOTTOM
 SUBSTRATES.
 OPENINGS 7 & 8, DUE TO THE SIZE IT APPEARS THAT THEY
 ARE SLIDING GLASS DOORS. THE FLOOR PLAN IS NOT CLEAR.
 THESE TWO OPENINGS ARE LIKELY CONCRETE TOP & BOTTOM,
 BUT I WAS UNABLE TO LOCATE MOUNTING CONNECTION TYPE
 "D2" ON THE PRODUCT APPROVAL (SEE PAGES 4 & 5 - A, B, C
 ONLY).
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-03-07 Cont ID  
Sent By shill Date 2015-03-07 Time 13:16 Rev Time 0.00
Received By shill Date 2015-03-07 Time 13:08 Sent To  
Notes
2015-03-07 13:14:51****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. OK
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 3. NEW COMMENT - IT IS NOT POSSIBLE TO DETERMINE
 CORRELATE THE PRODUCT APPROVALS WITH THE OPENINGS. FOR
 INSTANCE:
  
 PRODUCT APPROVAL 14610.5 VINYL HORIZONTAL ROLLER NON
 IMPACT HAS "WINDOW #3" WRITTEN ON IT, BUT OPENING #3
 DOES NOT HAVE SHUTTERS PROPOSED.
  
 14610.6 AND 17472.2 ARE IMPACT PRODUCTS, "W-3" WRITTEN
 ON BOTH.
  
 REVISE THE FLOOR PLAN TO INDICATE TYPE OF WINDOW
 PROPOSED (CORRELATE WITH THE PRODUCT APPROVAL),
 INDICATE LOCATION OF THE IMPACT WINDOWS. PROVIDE THE
 SIZES OF ALL OPENIINGS AND THE ADDITIONAL INFORMATION
 REQUIRED FOR BEDROOM WINDOWS AS INDICATED IN ITEM #2.
  
 THE PAGE PROVIDED PREVIOUSLY NO LONGER CORRELATES WITH
 THE NEW FLOOR PLAN AND PRODUCT APPROVALS PROVIDED. FOR
 INSTANCE, OPENING #3 ON THE CHART PROVIDED IN FIRST
 SUBMITTAL STATES THAT FL1850 R9 IS PROPOSED, NOT
 CONSISTENT WITH THE NEW INFORMATION.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-29 Cont ID  
Sent By shill Date 2014-12-29 Time 09:19 Rev Time 0.00
Received By shill Date 2014-12-29 Time 09:19 Sent To  
Notes
2014-12-29 09:21:07****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. FOR THE PROPOSED ACCORDION SHUTTERS, COMPLETE THE
 SAMPLE INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION
 TO SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC
 R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS
 AVAILABLE IN THE LOBBY OR ON THE INTERNET AT
  
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/SCHEDULE_FOR_INSTALLATION.PDF
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-07-05 Cont ID  
Sent By shill Date 2015-07-05 Time 14:20 Rev Time 0.00
Received By shill Date 2015-06-15 Time   Sent To B
Notes
2015-06-16 11:20:10TO S.HILL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-07 Cont ID  
Sent By shill Date 2015-03-07 Time 13:16 Rev Time 0.00
Received By shill Date 2015-02-25 Time 11:45 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-29 Cont ID  
Sent By shill Date 2014-12-29 Time 09:21 Rev Time 0.00
Received By shill Date 2014-12-29 Time 09:21 Sent To  
Notes
2014-12-22 16:32:24ROUTED TO MISC1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved