Plan Review Details - Permit 14120532
Plan Review Stops For Permit 14120532
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-12-24 Cont ID  
Sent By jwitmer Date 2014-12-24 Time 14:31 Rev Time 0.00
Received By jwitmer Date 2014-12-24 Time 14:31 Sent To  
Notes
2014-12-24 14:33:40BUILDING PROVISO;
 THE ACCESSIBLE REST ROOM NEEDS TO HAVE AN ACCESSIBLE
 DOOR, MUST MEET MANEUVERING CLEARANCES 2010 FBC-ACC.
 TABLE 404.4.2.1. 18 INCHES LATCH SIDE OF DOOR TO WALL.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-01-09 Cont ID  
Sent By sciard Date 2015-01-09 Time 10:02 Rev Time 0.00
Received By sciard Date 2015-01-09 Time 10:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-02 Cont ID  
Sent By sciard Date 2015-01-02 Time 12:27 Rev Time 0.00
Received By sciard Date 2015-01-02 Time 12:27 Sent To  
Notes
2015-01-02 12:34:581. SHOW LOCATION OF PANELS A & B AND IDENTIFY ON PLANS.
 BRANCH CIRCUITS IN AREA BEING SERVED ORIGINATE IN BOTH
 PANELBOARDS.
 2. N.E.C. 700.12(F) SHOW LOCATION OF ALL EMERGENCY
 LIGHTS NEEDED FOR 1 FT. CANDLE FOR EGRESS.
 3. N.E.C. 210.63. LOCATION OF RECEPTACLE OUTLET WITHIN
 25 FEET OF AIR CONDITIONING EQUIPMENT AND GFCI
 PROTECTED PER N.E.C. 210.8(B).

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-12-16 Cont ID  
Sent By pleduc Date 2014-12-16 Time   Rev Time 0.00
Received By pleduc Date 2014-12-16 Time 14:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-01-09 Cont ID  
Sent By sciard Date 2015-01-09 Time 10:02 Rev Time 0.00
Received By sciard Date 2015-01-08 Time   Sent To  
Notes
2015-01-09 08:17:18INCOMING SENT TO STEVE CIARDIELLOS' DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-02 Cont ID  
Sent By hmoser Date 2015-01-02 Time 13:14 Rev Time 0.00
Received By hmoser Date 2014-12-15 Time 17:22 Sent To  
Notes
2014-12-15 17:27:45B29

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-12-24 Cont ID  
Sent By jwitmer Date 2014-12-24 Time 14:31 Rev Time 0.00
Received By jwitmer Date 2014-12-24 Time 14:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-01-02 Cont ID  
Sent By hmoser Date 2015-01-02 Time 13:14 Rev Time 0.00
Received By hmoser Date 2015-01-02 Time 12:50 Sent To  
Notes
2015-01-02 13:21:03SIZE DUCT GOING TO 14 X 4 SIDE WALL BE FOR ROUGH
 INSPECTION
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
2015-01-02 13:14:03 
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-12-20 Cont ID  
Sent By tklarge Date 2014-12-20 Time 10:52 Rev Time 0.00
Received By tklarge Date 2014-12-20 Time 10:37 Sent To  
Notes
***NONE***