Plan Review Details - Permit 14120391
Plan Review Stops For Permit 14120391 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-07 |
Time |
17:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-03-07 |
Time |
17:35 |
Sent To |
|
|
Notes |
2015-03-07 17:38:04 | ****PROVISO**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | CONTRACTOR HAS ELECTED NOT TO SUBMIT FIXTURE CALCS | | DURING PLAN REVIEW. | | | | CONTRACTOR TO PROVIDE FIXTURE CALCS AT INSPECTION. | | SUBJECT TO FIELD INSPECTOR'S DISCRETION, A REVISION | | (WITH FEES) MAY BE REQUIRED. IF THIS IS NOT ACCEPTABLE | | TO THE CONTRACTOR, HE SHOULD NOT PICK UP THE PERMIT AND | | SHOULD RESUBMIT WITH FIXTURE CALCS. | | | | PER ENGINEER'S CALCS: | | | | FIXTURE TO BE MOUNTED AT 25' ABOVE BOTTOM OF BASE PLATE | | OR TRANSFORMER PLATE | | FIXTURE EPA NOT TO EXCEED 2.4 SF | | FIXTURE WEIGHT NOT TO EXCEED 54# | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-01-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-01-07 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-01-07 |
Time |
12:25 |
Sent To |
|
|
Notes |
2015-01-07 12:41:19 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. LIGHT POLE CALCULATIONS USE RISK CATEGORY II, | | 160MPH. RISK CATEGORY I IS TO BE A MINIMUM OF 150MPH, | | RISK CATEGORY II AT THIS LOCATION IS 169MPH (170MPH IS | | "WORST CASE" FOR THIS JURISDICTION). PLEASE REVISE | | CALCS; 160MPH IS ACCEPTABLE BUT MUST STATE RISK | | CATEGORY 1. | | | | 2. THE ENGINEER'S SEAL (DANNY EUGENE DOSS, PE) ON | | SHEETS SL1, P1.0 (AND ANY OTHER APPLICABLE SHEETS) USE | | AN EXPIRED SEAL ("CERTIFICATE" RATHER THAN "LICENSE"), | | FAC61G15-23, PLEASE CORRECT. | | | | 3. ENGINEERING FOR FIXTURES CAN BE PROVIDED NOW OR WILL | | BE REQUIRED AT INSPECTION, FBC 1609. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-03-06 |
|
|
Cont ID |
|
Sent By |
sciard |
Date |
2015-03-06 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
sciard |
Date |
2015-03-06 |
Time |
11:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-12-30 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-12-30 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-12-30 |
Time |
14:25 |
Sent To |
Z |
|
Notes |
2014-12-30 16:26:24 | 12/30/2014 | | PROJECT: SITE LIGHTING AUTOZONE | | PERMIT#: 14120391 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) SHEET E-1 IS PART OF APPLICATION #14110892 FOR THE | | RENNOVATION OF THE AUTOZONE STORE AND HAS NO BEARING ON | | THE INSTALLATION OF THE SITE LIGHTING. | | | | 2) SHEET E-4 IS ALSO PART OF APPLICATION #14110892 FOR | | THE RENNOVATION OF THE AUTOZONE STORE AND HAS NO | | BEARING ON THE INSTALLATION OF THE SITE LIGHTING. | | | | 3) IT APPEARS THERE IS A NEW SITE LIGHTING CIRCUIT | | PROPOSED FROM PANEL A" PROVIDE A PANEL SCHEDULE FOR | | PANEL A. | | | | 4) THERE IS A SYMBOL INDICATED FOR WALL PACKS ON THE | | EXTERIOR OF THE NEW AUTOZONE ADITION. IS THIS A PART OF | | THE SITE LIGHTING SCOPE? IF SO INCLUDE THE CIRCUITRY | | THAT FEEDS THEM. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-07 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-13 |
Time |
|
Sent To |
|
|
Notes |
2015-02-18 09:39:30 | SENT TO ZONING BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-01-07 |
Time |
12:41 |
Rev Time |
|
Received By |
shill |
Date |
2014-12-09 |
Time |
|
Sent To |
|
|
Notes |
2014-12-10 14:52:02 | SENT TO D. HAYES'S DESK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2015-02-24 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2015-02-24 |
Time |
09:53 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-12-31 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2014-12-31 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2014-12-31 |
Time |
16:31 |
Sent To |
B |
|
Notes |
2014-12-31 16:37:29 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 12.31.2014 | | PERMIT NO.: 14120391 | | ADDRESS: 7300 SOUTH DIXIE HIGHWAY | | CONTRACTOR/CONTACT: JACOB LAWSON | | TELEPHONE NO.: 772.794.4110 | | SCOPE OF REVIEW: WAREHOUSE/STORAGE ADDITION TO EXISTING | | AUTO PARTS STORE - LANDSCAPING. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PRIOR TO THE ISSUANCE OF A PERMIT, A UNITY OF TITLE | | SHALL BE RECORDED IN THE PUBLIC RECORDS OF PALM BEACH | | COUNTY. PLEASE CONTACT VINCE NOEL, CITY SURVEYOR AT | | 561.494.1096 OR [email protected] FOR AN APPLICATION. A | | COPY OF THE UNITY OF TITLE SHALL BE PROVIDED WITH THE | | BUILDING PERMIT PACKAGE. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1448 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.WPB.ORG | | | | 12/1/14 |
|
|
|
Account Summary | Usage Policy | Privacy Policy