Plan Review Stops For Permit 14120369 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-04-16 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-02-03 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-02-03 |
Time |
16:54 |
Sent To |
|
|
Notes |
2015-02-03 17:30:40 | BUILDING PLAN REVIEW | | PERMIT: 14120369 | | ADD: 101 N. CLEMATIS ST. | | CONT: TBD | | TEL: (305)606-0567 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: TUES. FEB. 03/ 2015 | | ACTION: DENIED | | | | 1)COMPLIED. | | | | 2) 2ND REQUEST SUBMITTED FLOOR INSULATION FOR GENIEMAT | | TESTED TO ASTM E2179 THE WRONG STANDARD, PLEASE PROVIDE | | COMPLIANCE WITH THE (2) REQUIREMENTS LISTED BELOW: | | | | 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 2B) FBC-B 2010 603.2 EXCEPTION (2) TILE FLOORING. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-12-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-17 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-17 |
Time |
14:10 |
Sent To |
|
|
Notes |
2014-12-17 14:18:55 | BUILDING PLAN REVIEW | | PERMIT: 14120369 | | ADD: 101 N. CLEMATIS ST. | | CONT: TBD | | TEL: (305)606-0567 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. DEC. 16/ 2014 | | ACTION: DENIED | | | | 1) THE ARCHITECTURAL SHEETS ARE SIGNED INBOTH SETS OF | | PLANS BUT NOT SEALED. | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | FL ADMIN CODE 61G16.003 ARCHITECTS. | | | | 2) IT APPEARS THAT THE BATHROOM WILL HAVE A NEW TILED | | FLOOR, PLEASE PROVIDE COMPLIANCE WITH THE 2010 FBC-B: | | | | 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 2B) FBC-B 2010 603.2 EXCEPTION (2) TILE FLOORING | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-03-10 |
|
|
Cont ID |
|
Sent By |
sciard |
Date |
2015-03-10 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
sciard |
Date |
2015-03-10 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-01-12 |
|
|
Cont ID |
|
Sent By |
sciard |
Date |
2015-01-12 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
sciard |
Date |
2015-01-12 |
Time |
14:24 |
Sent To |
|
|
Notes |
2015-01-12 14:45:38 | 1. FBC 107.3.5.3. PROVIDE LOAD CALCULATION A ND PANEL | | SCHEDULE FOR RELOCATED PANEL WITH ADDITION OF TANKLESS | | WATER HEATER. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-12-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-12-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-12-16 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-03-10 |
|
|
Cont ID |
|
Sent By |
sciard |
Date |
2015-03-10 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
sciard |
Date |
2015-01-29 |
Time |
07:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-01-14 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-01-14 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-01-07 |
Time |
07:05 |
Sent To |
|
|
Notes |
2015-01-08 07:08:01 | RESUBMITTAL WAS PUT IN WITH ORIGINAL PLANS THAT HAD NOT | | COMPLETED THE REVIEW CYCLE. MECHANICAL AND ELECTRICAL | | REVIEWS WERE NOT COMPLETED AT THIS TIME. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-14 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-01-14 |
Time |
14:22 |
Rev Time |
|
Received By |
hmoser |
Date |
2014-12-09 |
Time |
|
Sent To |
|
|
Notes |
2014-12-10 15:57:34 | INCOMING SENT TO B23. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-01-14 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-01-14 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-01-14 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-12-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-12-20 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-12-20 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-12-22 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-12-22 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-12-22 |
Time |
15:32 |
Sent To |
|
|
Notes |
2014-12-11 10:37:24 | 12/11/14 |
|
|