Plan Review Details - Permit 14120181
Plan Review Stops For Permit 14120181 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-01-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-31 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-31 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-12-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-12-31 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-12-31 |
Time |
10:33 |
Sent To |
E |
|
Notes |
2014-12-31 15:20:46 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) ON SHEET A-1, THE WRONG EDITION OF ASCE 7 IS | | SPECIFIED. ASCE 7 - 10 IS THE STANDARD THAT IS | | REFERENCED IN CHAPTER 43 OF THE 2010 FBC RESIDENTIAL. | | | | 2) THE FIRST FLOOR PLAN ON SHEET A-2 APPEARS TO SHOW | | THE NEW SLIDING GLASS DOORS AS THREE PANELS. THE DOOR | | AND WINDOW SCHEDULE ON SHEET A-2 INDICATES THAT THE 9' | | X 8' SLIDING GLASS DOORS ARE 2 PANELS. PLEASE CLARIFY. | | FBC 107.2.1 | | | | 3) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW | | 16' X 7' OVERHEAD GARAGE DOOR AND THE NEW 6' X 8' | | DOUBLE OUTSWING ENTRY DOOR THAT HAVE BEEN REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. DCA RULE | | 9N-3 AND FBC 107.3.4.1 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-01-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-01-23 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-01-23 |
Time |
12:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-01-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-01-31 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-01-27 |
Time |
10:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-01-23 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-12-08 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-12-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-12-20 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-12-20 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
|