Plan Review Details - Permit 14120130
Plan Review Stops For Permit 14120130 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-06-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-29 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-29 |
Time |
10:39 |
Sent To |
|
|
Notes |
2015-06-29 10:52:19 | BUILDING PLAN REVIEW | | PERMIT: 14120130 | | ADD: 1901 S. DIXIE HWY. | | CONT: SISCACONSTRUCTION | | TEL: (561)686-5545 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | DATE: MON. JUNE 29/ 2015 | | ACTION: BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | 1C) PROVISO: THE PLANS INDICATE A PROPOSED UNDERGROUND | | FIRE LINE TAP.2010 FBC-B 903.1.2 GROUP A2 WHEN THE FIRE | | AREA HAS AN OCCUPANT LOAD OF 100 OR MORE FIRE | | SPRINKLERS ARE REQUIED. 107.3.5 MINIMUM PLAN REVIEW | | CRITERIA FOR BUILDINGS. 107.3.5.1 COMMERCIAL BUILDINGS | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC | | FIRE SPRINKLERS | | | | 2A) BUILDING PROVISO: MON. JUNE 29/ 2015 RECEIVED | | SIGNED & SEALED LETTER FROM THE DESIGNER OF RECORD THAT | | A REVISION WILL BE FORTH COMING CORRECTING THE FRONT | | ENTRY DOORS TO BE OUT SWING BUT OVER THE PROPERTY LINE, | | THE REVISION WILL NEED TO BE INTO THE BUILDING | | DEPARTMENT AND APPROVED BEFORE THE FRAMING INSPECTION | | CAN OCCUR. | | | | 2B) APPROVED, LETTER FROM THE DESIGNER OF RECORD | | SHOWING COMPLIANCE WITH 2010 FL. ACCESSIBILTY CODE SEE | | SECTION 202.4.1 DISPROPORTIONATE COST. | | | | 3A) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | APPROVED BY THE BUILDING OFFICIAL. 2010 FBC-B 1609.1.2 | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | SYSTEMS | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (G) PRE-ENGINEERED A/C STANDS | | | | 4) PROVISO: SUBMIT BEFORE 1ST INSPECTION FOR FOOTINGS. | | SHEET S4.0 ALSO HAS STATEMENTS FOR SOILS REPORTS FOR | | ALL OF THE NEW FOUNDATIONS FOR THE MEZZANINE LEVEL. THE | | ASSUMED SAFE BEARING VALUE OF THE SOILS IS 2500 PSF. | | NOTE 3 READS: SOILS SUPPORTING ALL FOOTING MUST BE | | INSPECTED AND APPROVED BY A REGISETERD SOILS ENGINEER | | BEFORE COMMENCING WORK. APPROVED IN WRITING MUST | | INDICATE THE SOIL IS ADEQUATE TO SAFETLY SUSTAIN | | SPECIFIED SOIL BEARING PRESSURE. 2010 FBC-B 1803.2 | | INVESTIGATIONS REQUIRED. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-19 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-19 |
Time |
15:07 |
Sent To |
|
|
Notes |
2015-06-19 17:04:18 | BUILDING PLAN REVIEW | | PERMIT: 14120130 | | ADD: 1901 S. DIXIE HWY. | | CONT: SISCACONSTRUCTION | | TEL: (561)686-5545 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: FRI. JUNE 19/ 2015 | | ACTION: DENIED | | | | 1) COVERSHEET INDICATES UNDER THE CODE ANALYSIS: | | 1A-B) COMPLIED. . | | | | 1C) PROVISO: THE PLANS INDICATE A PROPOSED UNDERGROUND | | FIRE LINE TAP.2010 FBC-B 903.1.2 GROUP A2 WHEN THE FIRE | | AREA HAS AN OCCUPANT LOAD OF 100 OR MORE FIRE | | SPRINKLERS ARE REQUIED. 107.3.5 MINIMUM PLAN REVIEW | | CRITERIA FOR BUILDINGS. 107.3.5.1 COMMERCIAL BUILDINGS | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC | | FIRE SPRINKLERS | | | | 2) SITE PLAN AP 1.0: | | | | 2A) 3RD REQUEST. ALL 3 VERSIONS OF THIS PLAN SHOWS A | | NEW FRONT ENTRY, WITH DOORS THAT SWING OUT OVER THE | | PROPERTY LINE. THE CURRENT SET OF DOORS ARE IN SWING | | DOORS. 2010 FBC-B 3202.2 ENCROACHMENTS ABOVE GRADE AND | | BELOW 8 FEET IN HEIGHT. DOORS AND WINDOWS SHALL NOT | | OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | 2B) THE CITY HAS AN ISSUE WITH SUBMITTED | | DISPROPORTIONATE COST BREAK DOWN FOR THIS PROJECT. THE | | PERMIT APPLICATION VALUE IS INDICATED AS $336,000.00 | | DOLLARS BUTTHE TOTAL DISPROPORTIONATE COST TOTALS | | $304,175.00 DOLLARS. THE MEP SUBCONTRACTORS, FIRE | | SPRINKLER AND OTHER MISC. PERMITS CAN'T ADD UP TO | | $31,825 DOLLARS. PLEASE HAVE THE CONTRACTOR PROVIDE A | | TRUE COST BREAK DOWN OF THE TOTAL JOB COST AND THE COST | | ASSOCIATED WITH THE ACCESSIBLE ELEMENTS THAT MAY MEET | | DISPROPORTIONATE COST. | | 2010 FL. ACCESSIBILTY CODE SEE SECTION 202.4.1 AND | | 202.4.1 DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR | | DESIGNER OF RECORD ON THEIR LETTER HEAD PROVIDE A COST | | BREAKDOWN WHERE $67,200.00 DOLLORS WILL BE SPENT IN | | ACCESSIBLE UPGRADES. PLEASE NOT THE ORDER IN WHICH THE | | FUNDS ARE TO BE SPENT. FL ACC. CODE 202.4.2. (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | 2C) COMPLIED | | | | 3) COMPLIED. | | | | 4) THE OPTION OF DEFERRRED SUBMITTALS IS UP TO THE | | CONTRACTOR AND OR THE DESIGNERS, NOT MY REQUEST. IF | | EITHER THE CONTRACTOR AND OR DESIGNER WOULD PREFER TO | | TAKE ADVANTAGE OF THE DEFERRED SUBMITTALS PLEASE | | INDICATE YOU WOULD LIKE TO DO SO AND THE PRODUCT | | APPROVALS WILL BE DEFERRED UNTIL AFTER PERMIT ISSUANCE. | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | SYSTEMS | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (G) PRE-ENGINEERED A/C STANDS | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 6) COMPLIED. | | | | 7) PROVISO: SUBMIT BEFORE 1ST INSPECTION FOR FOOTINGS. | | SHEET S4.0 ALSO HAS STATEMENTS FOR SOILS REPORTS FOR | | ALL OF THE NEW FOUNDATIONS FOR THE MEZZANINE LEVEL. THE | | ASSUMED SAFE BEARING VALUE OF THE SOILS IS 2500 PSF. | | NOTE 3 READS: SOILS SUPPORTING ALL FOOTING MUST BE | | INSPECTED AND APPROVED BY A REGISETERD SOILS ENGINEER | | BEFORE COMMENCING WORK. APPROVED IN WRITING MUST | | INDICATE THE SOIL IS ADEQUATE TO SAFETLY SUSTAIN | | SPECIFIED SOIL BEARING PRESSURE. 2010 FBC-B 1803.2 | | INVESTIGATIONS REQUIRED. | | | | 8-10) COMPLIED. | | | | 12) COMPLIED. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-09 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-05-12 |
Time |
13:40 |
Sent To |
|
|
Notes |
2015-04-09 15:51:10 | BUILDING PLAN REVIEW | | PERMIT: 14120130 | | ADD: 1901 S. DIXIE HWY. | | CONT: SISCACONSTRUCTION | | TEL: (561)686-5545 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: THURS. 09/ 2015 | | ACTION: DENIED | | | | 1) COVERSHEET INDICATES UNDER THE CODE ANALYSIS: | | 1A-B) COMPLIED. | | | | 1C) 2ND REQUEST SUBMIT FIRE SPRINKLER PLANS. THE PLANS | | INDICATE THERE IS AN EXISTING FIRE SPRINKLER. NOT SHOWN | | ON PLANS NOR IS THERE ANY ADDITIONAL LAYOUT OF FIRE | | SPRINKLER HEADS FOR THE PROPOSED MEZZANINE LEVEL. SINCE | | THIS IS A CHANGE OF OCCUPANCY UNDER THE EXISITNG | | BUILDING CODE SECTION 904.1 REFERS TO SECTION 912. | | | | 2010 EXT. BLDG. CODE 912.2.1 FIRE SPRINKLER SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. | | | | 2010 FBC-B 903.1.2 GROUP A2 WHEN THE FIRE AREA HAS AN | | OCCUPANT LOAD OF 100 OR MORE FIRE SPRINKLERS ARE | | REQUIED. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC | | FIRE SPRINKLERS | | | | 2) SITE PLAN AP 1.0: | | | | 2A) 2ND REQUEST. NOTE THE SITE PLAN APPEARS THE FRONT | | ENTRY WALL AND DOOR IS WITHIN OR ON THE PROPERTY LINE. | | 2010 FBC-B 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 | | FEET IN HEIGHT. DOORS AND WINDOWS SHALL NOT OPEN OR | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | 2B) 2ND REQUEST. THE DISPROPORTIONATE COST SUBMITTED | | WAS REJECTED BY THE BUILDING OFFICIAL THERE ARE LINE | | ITEMS THAT DO NOT PERTAIN TO ACCESSIBILITY. PLEASE | | REVIEW SECTION | | 202.4.2 ACCESSIBILITY WHICH CAN BE DEDUCTED, : (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (V) | | ACCESSIBLE DRINKING FOUNTAINS AND (VI) WHEN POSSIBLE | | PARKING LOTS. THE FRONT ENTRY OVER THE PROPERTY LINE | | THE COST OF REFRAMING, THE DOOR FRAME AND LABOR CAN NOT | | BE COUNTED, A NEW ACCESSIBLE THRESHOLD OR DOOR LATCH | | YES, RESTROOMS COSTS ASSOCIATED WITH MAKING RESTROOMS | | ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, ENLARGING | | TOILET STALLS, INSULATING PIPES, OR INSTALLING | | ACCESSIBLE FAUCET CONTROLS; THE BUILDING OFFICIAL WOULD | | ALLOW THE REFRAMING FOR ACCESSIBLE RESTROOMS. | | | | THE SITE PLAN DOES NOT SHOW THE PARKING LOT DOUBLE | | STRIPED TO THE CITY MUNI CODE. THE SITE PLANS FAILS TO | | SHOW COMPLIANCE WITH THE 2010 FL. EXT. BLDG. CODE 906.1 | | WHICH REFERS YOU BACK TO THE 2010 FL. ACCESSIBILTY CODE | | SEE SECTION 202.4.1 AND 202.4.1 DISPROPORTIONATE COST. | | EITHER THE CONTRACTOR OR DESIGNER OF RECORD ON THEIR | | LETTER HEAD PROVIDE A COST BREAKDOWN WHERE $67,200.00 | | DOLLORS WILL BE SPENT IN ACCESSIBLE UPGRADES. PLEASE | | NOT THE ORDER IN WHICH THE FUNDS ARE TO BE SPENT. FL | | ACC. CODE 202.4.2. (I) AN ACCESSIBLE ENTRANCE; (II) AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST | | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX | | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE | | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | ZONING STATED THAT THE 50% RULE FOR LANDSCAPING BUT IT | | WOULD NOT REQUIRE THE RESTRIPPING OF THE PARKING LOT, | | IT WILL BE DETERMINED BY IF THE FUNDS SENT FOR | | DISPROPORTIONALITY ARE USED UP BEFORE THE PARKING LOT | | GETS INVOLVED FOR ACCESSIBLITY. | | | | 2C) NOTE TO GAIN ENTRY TO THE FRONT OF THE BUILDING YOU | | WILL BE CROSSING A ALLEYWAY WHERE DETECTABLE WARNINGS | | WOULD BE REQUIRED SINCE THIS IS A PUBLIC RIGHT OF WAY. | | 2010 FL. ACCESSIBILITY CODE 705. | | | | 3) COMPLIED, WINDOW PRESSURES ARE GOOD. | | | | 4-5) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | SYSTEMS | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (G) PRE-ENGINEERED A/C STANDS | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 6) COMPLIED. | | | | 7) 2ND REQUEST. SHEET S4.0 ALSO HAS STATEMENTS FOR | | SOILS REPORTS FOR ALL OF THE NEW FOUNDATIONS FOR THE | | MEZZANINE LEVEL. THE ASSUMED SAFE BEARING VALUE OF THE | | SOILS IS 2500 PSF. NOTE 3 READS: SOILS SUPPORTING ALL | | FOOTING MUST BE INSPECTED AND APPROVED BY A REGISETERD | | SOILS ENGINEER BEFORE COMMENCING WORK. APPROVED IN | | WRITING MUST INDICATE THE SOIL IS ADEQUATE TO SAFETLY | | SUSTAIN SPECIFIED SOIL BEARING PRESSURE. 2010 FBC-B | | 1803.2 INVESTIGATIONS REQUIRED. | | | | 8) 2ND REQUEST. RESPONCE SEE DETAIL 11/A5.0, THIS | | DETAIL IS FOR A BULKHEAD OR SOFFIT NOT A DROPPED | | CEILING. SHEET A1.1 SHOWS A DROPPED CEILING OVER | | EXPOSITION KITCHEN AND PICK UP AREA, PLEASE PROVIDE | | DETAILS OF HOW THIS SYSTEM WILL BE ATTACHED TO THE | | FRAMING SYSTEM ABOVE THE GIRDERS APPEAR TO BE SPACED | | 10'-0" APART.107.2.1.3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 9)COMPLIED> SHEET A1.1 CEILING PLAN THERE IS A SYMBOL T | | THAT APPEARS NUMEROUS TIMES ON THE PLANS, THIS SYMBOL | | IS NOT FOUND IN THE CEILING PLAN LEGEND. 107.2.1.3 | | ADDITIONAL INFORMATION IS REQUIRED. | | | | 10) 2ND REQUEST SHEET A1.0, A1.2 THE MAIN FLOOR PLAN | | DOES NOT PROVIDE ANY INTERIOR ELEVATIONS FOR THE PICK | | UP AREA SHOWING COMPLIANCE WITH 2010 FL ACCESS. CODE | | 904.4. SALES AND SERVICE COUNTERS. SALES COUNTERS AND | | SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2. | | THE ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND | | THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. | | | | 11) COMPLIED. | | | | 12) COMPLIED. | | | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-01-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-19 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-18 |
Time |
13:15 |
Sent To |
|
|
Notes |
2014-12-19 14:40:35 | BUILDING PLAN REVIEW | | PERMIT: 14120130 | | ADD: 1901 S. DIXIE HWY. | | CONT: SISCACONSTRUCTION | | TEL: (561)686-5545 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. DEC. 19/ 2014 | | ACTION: DENIED | | | | 1) COVERSHEET INDICATES UNDER THE CODE ANALYSIS: | | 1A) THIS PLAN IS DESIGNED UNDER THE 2010 FBC-EXISTING | | BUILDING CODE AS A LEVEL II ALTERATION. PLEASE NOTE FOR | | THIS ADDRESS THE CITY HAS A CURRENT BUSINESS TAX | | (OCCUPATIONAL LICENSE) FOR REWARDS LIGHTING. WITH A | | CHANGE OF OCCUPANCY PLANS ARE TO BE DESIGNED IN | | ACCORDANCE WITH CHAPTER 9 OF THE EXISTING BUILDING | | CODE, CHANGE OF OCCUPANCY SEE SECTIONS 901.3 . WHERE | | THE OCCUPANCY CLASSIFICATION OF A BUILDING CHANGES, THE | | PROVISIONS OF SECTIONS 902 THROUGH 912 SHALL APPLY. | | | | 1B) THE CODE ANALYSIS DOES NOT PROVIDE WHAT TYPE OF | | CONSTRUCTION THIS BUILDING IS? 2010 FBC-B TABLE 503. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: (3) MINIMUM TYPE OF | | CONSTRUCTION SHALL BE DETERMINED (SEE TABLE 503). | | | | 1C) THE PLANS INDICATE THERE IS AN EXISTING FIRE | | SPRINKLER. NOT SHOWN ON PLANS NOR IS THERE ANY | | ADDITIONAL LAYOUT OF FIRE SPRINKLER HEADS FOR THE | | PROPOSED MEZZANINE LEVEL. SINCE THIS IS A CHANGE OF | | OCCUPANCY UNDER THE EXISITNG BUILDING CODE SECTION | | 904.1 REFERS TO SECTION 912. | | | | 2010 EXT. BLDG. CODE 912.2.1 FIRE SPRINKLER SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. | | | | 2010 FBC-B 903.1.2 GROUP A2 WHEN THE FIRE AREA HAS AN | | OCCUPANT LOAD OF 100 OR MORE FIRE SPRINKLERS ARE | | REQUIED. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC | | FIRE SPRINKLERS | | | | 2) SITE PLAN AP 1.0: | | | | 2A) NOTE THE SITE PLAN APPEARS THE PROPERTY LINE IS | | WITHIN OR ON THE PROPERTY LINE. THE LIFE SAFETY PLANS | | INDICATE REAR DOORS THA WILL SWING OUT OVER THE | | PROPERTY LINE INTO THE TRAFFIC LANE OF THE ALLEYWAY. | | 2010 FBC-B 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 | | FEET IN HEIGHT. DOORS AND WINDOWS SHALL NOT OPEN OR | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | 2B) THE SITE PLAN DOES NOT SHOW THE PARKING LOT DOUBLE | | STRIPED TO THE CITY MUNI CODE. THE SITE PLANS FAILS TO | | SHOW COMPLIANCE WITH THE 2010 FL. EXT. BLDG. CODE 906.1 | | WHICH REFERS YOU BACK TO THE 2010 FL. ACCESSIBILTY CODE | | SEE SECTION 202.4.1 AND 202.4.1 DISPROPORTIONATE COST. | | EITHER THE CONTRACTOR OR DESIGNER OF RECORD ON THEIR | | LETTER HEAD PROVIDE A COST BREAKDOWN WHERE $67,200.00 | | DOLLORS WILL BE SPENT IN ACCESSIBLE UPGRADES. PLEASE | | NOT THE ORDER IN WHICH THE FUNDS ARE TO BE SPENT. FL | | ACC. CODE 202.4.2. (I) AN ACCESSIBLE ENTRANCE; (II) AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST | | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX | | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE | | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | 2C) NOTE TO GAIN ENTRY TO THE FRONT OF THE BUILDING YOU | | WILL BE CROSSING A ALLEYWAY WHERE DETECTABLE WARNINGS | | WOULD BE REQUIRED SINCE THIS IS A PUBLIC RIGHT OF WAY. | | 2010 FL. ACCESSIBILITY CODE 705. | | | | 3) SHEET A2.0 THERE IS A SECTION THRU THE BUILDING | | PROVIDING SCALED MEAN ROOF HEIGHT OF 18.22 FT. AND THE | | PARAPET HEIGHT OF APPROX. 19.90 FT. THE ROOF PRESSURES | | FOUND ON SHEET S-4 ARE TAKEN AS A EXPOSURE C AT 20'-0" | | WHERE AS THE WINDOW AND DOOR PRESSURES ARE LOW FOR A | | BUILDING 20 FT HIGH, THEY ARE TAKEN FOR A 15 FOOT HIGH | | BUILDING C EXPOSURE. IT ALSO APPEARS THE PREESURES ARE | | LOW ON SHEET S7.0. NOTE THE PLANS ARE DRAWN IN 3/16 | | INCH SCALE BUT THERE IS NO MEASUREMENTS GIVEN TO DERIVE | | THE SIZE OF WINDOWS AND DOORS FOR ACCURATE SQ. FT OF | | AREA VERSES PRESSURES. | | | | | | 4) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | SYSTEMS | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (G) PRE-ENGINEERED A/C STANDS | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 6) NEITHER THE ARCHITECTURAL, STRUCTURAL OR MECHANICAL | | SHEETS SHOW THE ATTACHMENT METHOD FOR THE ROOFTOP UNITS | | (CURBS) WALK IN COOLER CONDENSING UNIT ROOF TOP STANDS | | OR THE HOOD EXHAUST FANS AND STANDS. PLEASE SHOW HOW | | THESE UNITS WILL BE ATTACHED TO THE ROOF FRAMING | | MEMBERS, HOW THE INFILE FRAMING TO SUPPORT THESE UNITS | | WIL BE DESIGNED, STRAPPING AND ANCHORING OF CURBS AND | | ANCHORING OF THE RTU,S AND EXHAUST FANS O THEIR CURBS. | | 2010 FBC-B | | 1609.8 ROOFTOP STRUCTURES AND EQUIPMENT. | | | | 7) SHEET S4.0 ALSO HAS STATEMENTS FOR SOILS REPORTS FOR | | ALL OF THE NEW FOUNDATIONS FOR THE MEZZANINE LEVEL. THE | | ASSUMED SAFE BEARING VALUE OF THE SOILS IS 2500 PSF. | | NOTE 3 READS: SOILS SUPPORTING ALL FOOTING MUST BE | | INSPECTED AND APPROVED BY A REGISETERD SOILS ENGINEER | | BEFORE COMMENCING WORK. APPROVED IN WRITING MUST | | INDICATE THE SOIL IS ADEQUATE TO SAFETLY SUSTAIN | | SPECIFIED SOIL BEARING PRESSURE. 2010 FBC-B 1803.2 | | INVESTIGATIONS REQUIRED. | | | | 8) SHEET A1.1 SHOWS A DROPPED CEILING OVER EXPOSITION | | KITCHEN AND PICK UP AREA, PLEASE PROVIDE DETAILS OF HOW | | THIS SYSTEM WILL BE ATTACHED TO THE FRAMING SYSTEM | | ABOVE THE GIRDERS APPEAR TO BE SPACED 10'-0" | | APART.107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 9) SHEET A1.1 CEILING PLAN THERE IS A SYMBOL T THAT | | APPEARS NUMEROUS TIMES ON THE PLANS, THIS SYMBOL IS NOT | | FOUND IN THE CEILING PLAN LEGEND. 107.2.1.3 | | ADDITIONAL INFORMATION IS REQUIRED. | | | | 10) SHEET A1.0 THE MAIN FLOOR PLAN DOES NOT PROVIDE ANY | | INTERIOR ELEVATIONS FOR THE PICK UP AREA SHOWING | | COMPLIANCE WITH 2010 FL ACCESS. CODE 904.4. | | | | 11) THE PLANS WILL ALSO NEED TO SHOW COMPLIANCE WITH | | THESE ACCESSIBLE ELEMENTS: 902.1 GENERAL. DINING | | SURFACES AND WORK SURFACES SHALL COMPLY WITH 902.2 AND | | 902.3. | | EXCEPTION: DINING SURFACES AND WORK SURFACES FOR | | CHILDREN?S USE SHALL BE PERMITTED TO COMPLY WITH 902.4. | | ADVISORY 902.1 GENERAL. | | DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, | | TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK | | SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, | | STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER | | TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON | | COUNTERS, AND WHERE COVERED BY THE ABA SCOPING | | PROVISIONS, EMPLOYEE WORK STATIONS. | | | | 11A) 2010 FL ACC CODE 902.2 CLEAR FLOOR OR GROUND | | SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305 | | POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. | | KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE | | PROVIDED. | | | | 11B) 2010 FL ACC CODE 902.3 HEIGHT. THE TOPS OF DINING | | SURFACES AND WORK SURFACES SHALL BE 28 INCHES (710 MM) | | MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-04-02 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-04-02 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-04-02 |
Time |
11:35 |
Sent To |
|
|
Notes |
2015-04-02 12:23:07 | NOTE PLACED ON PLANS INDICATING THAT THE ELECTRIC | | EQUIPMENT, GRILLS, OVENS, ETC. MUST BE LISTED BY A | | NATIONALLY RECOGNIZED TESTING LABORATORY. NEC 90.7 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-01-27 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-01-27 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-01-22 |
Time |
12:20 |
Sent To |
|
|
Notes |
2015-01-27 12:53:44 | 14120130 | | 1901 S DIXIE HWY | | INTERIOR IMPROVEMENT | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENT. | | | | VERIFY THIS BUILDING WILL HAVE ONLY ONE POINT OF | | ELECTRICAL SERVICE. INDICATE | | THE INTENDED USE FOR THE ELECTRICAL PANELS SHOW ON THE | | WEST EXTERIOR ELEVATION OF SHEET A3. NEC 230.2 | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR ALARM | | SYSTEMS, SECURITY, SITE LIGHTING AND DATA SYSTEMS. | | | | ROBERT LECKY, CBO | | ELECTRICAL PLANS REVIEW | | 561-373-3701 | | [email protected] | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2015-05-20 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-05-20 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-05-20 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-04-16 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-04-16 |
Time |
15:35 |
Sent To |
|
|
Notes |
2015-04-16 16:52:40 | 1901 SOUTH DIXIE HIGHWAY | | PERMIT #14120130 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SOLID FUEL COOKING OPERATIONS NEED TO CONFORM TO ALL | | THE REQUIREMENTS OF NFPA 96 (HOODS, EXHAUST, AIR | | MOVEMENT, FIRE PROTECTION, CLEANING/MAINTENANCE, FUEL | | STORAGE, EMBER/ASH MANAGEMENT, ETC.). THE PLANS AND | | EQUIPMENT ARE SEVERLY LACKING INFORMATION TO SHOW | | COMPLIANCE WITH ALL THE DETAILED REQUIREMENTS OF NFPA | | 96. | | | | ENGINEERED FIRE SPRINKLER CONSTRUCTION DOCUMENTS ARE | | REQUIRED FOR A GENERAL BUILDING PERMIT. AFTER THE | | BUILDING PERMIT HAS BEEN ISSUED, THE SUBCONTRACTORS CAN | | THEN SUBMIT SHOP DRAWINGS (CONFORMING TO THE ENGINEERED | | CONSTRUCTION DOCUMENTS) FOR A SUB-PERMIT. PER FLORIDA | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | PRE-ENGINEERED SYSTEMS. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2014-12-23 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-12-23 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-12-23 |
Time |
11:23 |
Sent To |
|
|
Notes |
2014-12-23 11:49:22 | 1901 SOUTH DIXIE HIGHWAY | | CHANGE OF OCCUPANCY FROM MERCANTILE TO ASSEMBLY | | PERMIT #14120130 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | GENERAL: PROVIDE DRAWING NOTE INDICATING, "FIRE | | PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | GENERAL: PER SECTION 10.12.1.2 (NFPA 1), PROVIDE | | BUILDING ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL | | BE ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES | | IN HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | BACKGROUND. | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | ORDERED FROM WWW.KNOXBOX.COM. | | | | CIVIL SITE: NO PARKING SIGNS WILL BE NEEDED ON KANUGA | | DRIVE TO PROVIDE FIRE DEPARTMENT ACCESS TO PROPOSED | | FIRE DEPARTMENT CONNECTION, BACKFLOW PREVENTER AND | | EXISTING FIRE HYDRANT. BACKFLOW PREVENTER WILL NEED TO | | BE PROTECTED FROM VEHICULAR TRAFFIC. | | | | SHEET LS: SECONDARY EXIT (KANUGA DRIVE) DOOR SWINGS | | INTO THE PUBLIC RIGHT OF WAY. | | | | SHEET A1.0: MAIN ENTRY DOOR EQUIPPED WITH THUMB TURN | | LOCK. FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN | | OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER | | THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE | | PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER | | LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE | | RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR | | PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE | | AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A | | READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN | | UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS | | SHALL BE AT LEAST 1 INCH IN HEIGHT. KEYED LOCK TO BE | | EQUIPPED WITH AN ?OPEN/LOCKED? INDICATOR WINDOW (SUCH | | AS ADAMS RITE 4089 OR SIMILAR). A THUMB TURN STYLE LOCK | | IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED LOCK. | | | | SHEET A1.2: AREA AT BOTTOM OF STAIR INDICATED AS | | RECEIVING AREA. WHAT SAFE GUARDS WILL BE IN PLACE TO | | ENSURE THE EXIT STAIR (SINGLE MEANS OF EGRESS) IS NEVER | | BLOCKED OR OBSTRUCTED? | | | | SHEET A2.0: THE CEILING AND STRUCTURE HEIGHTS CANNOT BE | | DETERMINED FOR THE UPPER LEVEL. HEAD CLEARANCES OF | | 7'-6" SHALL BE PROVIDED AND INDICATED ON THE PLANS. | | | | SHEET A2.0: PROVIDE A STORAGE LAYOUT. IN GENERAL, | | INDICATE THE COMMODITIES TO BE STORED, THE QUANTITY TO | | BE STORED, AND THE HEIGHT OF STORAGE, ETC. | | | | SHEET P2.1: EQUIPMENT SCHEDULE INDICATES A CHARCOAL | | GRILL (ITEM #74). SOLID FUEL AND FIRE PROTECTION | | INFORMATION AND DETAILS NEEDED FOR APPROVAL. | | | | FIRE PROTECTION: FOR ISSUANCE OF A GENERAL BUILDING | | PERMIT, SECTION 105.3.1.2(2) OF THE FLORIDA BUILDING | | CODE REQUIRES SEALED FIRE PROTECTION CONSTRUCTION | | DOCUMENTS FOR THE DESIGN OR ALTERATION OF 50 OR MORE | | AUTOMATIC FIRE SPRINKLERS. PER FLORIDA ADMINISTRATIVE | | CODE SECTION 61G15-32.004, FIRE PROTECTION ENGINEERING | | DOCUMENTS SHALL INCLUDE THE POINT OF SERVICE FOR THE | | WATER SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS | | APPLICABLE TO THE PROJECT, CLASSIFICATION OF HAZARD | | OCCUPANCY FOR EACH ROOM OR AREA, SUPPRESSION SYSTEM | | TYPE, DESIGN DENSITIES, WATER SUPPLY DATA (FIRE PUMP | | DATA, HYDRANT FLOW TEST DATA) AND ANY PERFORMANCE BASED | | INFORMATION SUCH AS PRE-ENGINEERED SYSTEMS. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2015-06-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-28 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-28 |
Time |
09:00 |
Sent To |
|
|
Notes |
2015-06-28 09:15:18 | THE GAS IS NOT APPROVED UNDER THIS PERMIT. A SEPARATE | | GAS PERMIT APPLICATION ALONG WITH SIGNED AND SEALED | | DRAWINGS AND COMBUSTION AIR CALCULATIONS SHALL BE | | SUBMITTED FOR REVIEW AND APPROVAL. | | T.LARGE |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2015-06-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-10 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-10 |
Time |
09:41 |
Sent To |
|
|
Notes |
2015-06-10 09:24:05 | 1) SHT. P1.2 - PLEASE EXPLAIN HOW YOU ARRIVED AT THE | | CUBIC FOOTAGE OF 94,880 FOR THE RESTAURANT. IT IS | | UNCLEAR TO ME HOW YOU ARRIVED AT YOUR COMBUSTION AIR | | CALCULATIONS. IN ACCORDANCE WITH THE STANDARD METHOD IN | | THE 2010 FGC SEC.304.5.1, 50 CU. FT. OF COMBUSTION AIR | | IS REQUIRED FOR EACH 1,000 BTU OF THE APPLIANCE RATING. | | TAKING THE TOTAL BTU LOAD THAT I HAVE CALCULATED AS THE | | BASIS FOR THE REQUIRED COMBUSTION AIR (1,559,000 | | DIVIDED BY 1000 = (1,559 ) X (50 CU. FT. ) = 77,950 CU. | | FT. OF COMBUSTION AIR REQUIRED. THE CUBIC FOOTAGE OF | | THE RESTAURANT ON P1.2 IS SHOWN AS 94,880 AND ALSO AS | | 81,900 BEING DIVIDED BY 50 CU.FT.AND ARRIVING AT AN | | ALLOWABLE BTU LOAD OF 1,897,000 BTU'S. PLEASE ENLIGHTEN | | ME AS I HAVE ABSOLUTELY NO IDEA AS TO HOW THESE REULTS | | WERE ATTAINED FOR THE REQUIREMENTS FOR THE COMBUSTION | | AIR. THERE IS NO REVISED DRAWING P1.2 THAT WAS | | SUBMITTED AS STATED IN YOUR RESPONSE OF 4/20/15. THERE | | IS VERSION 2 WHICH IS WHAT MY REVIEW COMMENTS ARE BASED | | UPON. CLARIFY. | | 2) THE BTU LOAD OF THE APPLIANCES LISTED ON SHT. P1.2 | | AND SHT. P0.3 DO NOT CORRELATE NOR DO THE TOTAL BTU'S.I | | HAVE ADDED THE BTU'S ON SHT. P1.2 AND IT TOTALS | | 1,559,000, NOT 1,649,000 AS SHOWN. CLARIFY. | | 3) SHT. P0.3 SHOWS THE BTU LOAD FOR RANGE #2 AS 70,000 | | AND SHT. P1.2 HAS THE BTU LOAD AS 140,000. CLARIFY. | | 4) SHT. P0.3 - TOTAL GAS CONSUMPTION TABLE SHOWS ONE | | (1) RANGE #1 LISTED AND SHT. P1.2 SHOWS TWO (2) RANGE | | #1 UNITS LISTED FOR A TOTAL OF 490,000 BTU'S. CLARIFY. | | 5) SHT. P0.3 - RANGE #3 IS SHOWN ON THE GAS RISER AND | | ON THE GAS CONSUMPTION LIST BUT NOT ON SHT.P1.2. | | CLARIFY. | | | | NOTE: A COMPREHENSIVE GAS REVIEW CANNOT BE DONE UNTIL | | ALL THE CORRECT BTU LOADS AND COMBUSTION AIR | | CALCULATIONS ARE SUBMITTED.I SUGGEST CONTACTING ME TO | | SET UP A MEETING TO REVIEW AND DISCUSS THESE COMMENTS. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-04-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-19 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-19 |
Time |
09:29 |
Sent To |
|
|
Notes |
2015-04-23 13:37:34 | 1) SUBMIT MANUF. SPECIFICATIONS FOR ALL GAS | | APPLIANCES/EQUIPMENT.ALL EQUIPMENT SHALL BE LISTED AND | | LABELED PER THE 2010 FUEL GAS CODE SEC.301.3. THE | | NARRATIVE RESPONSE REFERS TO SHT. QF 101FOR GAS | | EQUIPMENT AND SPECIFICATIONS. THERE IS NO SHT. QF 101. | | CLARIFY. | | 2) SUBMIT VENTING DETAILS FOR THE TANKLESS WATER | | HEATERS. THE TANKLESS WATER HEATERS ARE DIRECT VENT | | APPLIANCES AND THE VENTING IS USUALLY SHOWN IN THE | | MANUFACTURER'S INSTALLATION MANUAL. SUBMIT THE VENT | | DETAILS FROM THE MANUFACTURER.THE NARRATIVE RESPONSE | | STATES TO SEE SHT.P0.2 FOR WATER HEATER VENT | | DETAIL.THERE IS NO VENT DETAIL ON P0.2, JUST A CLOUDED | | EMPTY BOX. WPB AMEND. TO 2010 FBC SEC. 107.3.5.1.5. | | 3) SUBMIT MANUF. SPECIFICATION SHEETS FOR THE VENTLESS | | GAS REGULATORS. THE NARRATIVE RESPONSE REFERS TO SHT. | | P1.1B & ATTACHED CUT SHEET.THERE IS NO ADDITIONAL | | INFORMATION ON SHT.P1.1B & NO ATTACHED CUT SHEET. | | CLARIFY. | | 4) THE BTU LOAD OF THE APPLIANCES LISTED ON SHT. P1.2 | | AND SHT.P0.3 DO NOT CORRELATE. I HAVE ADDED THE BTU | | LOAD A FEW TIMES ON SHT. P1.2 AND THE TOTAL BTU LOAD I | | CALCULATED IS 1,559,000. CLARIFY. | | 5) SHT. P1.2 - PLEASE EXPLAIN HOW YOU ARRIVED AT THE | | CUBIC FOOTAGE OF 94,880 FOR THE RESTAURANT. IT IS | | UNCLEAR TO ME HOW YOU ARRIVED AT YOUR COMBUSTION AIR | | CALCULATIONS. IN ACCORDANCE WITH THE STANDARD METHOD IN | | THE 2010 FGC SEC.304.5.1, 50 CU. FT. OF COMBUSTION AIR | | IS REQUIRED FOR EACH 1,000 BTU OF THE APPLIANCE RATING. | | TAKING THE TOTAL BTU LOAD FROM COMMENT #4, 1,559,000 | | DIVIDED BY 1000 = (1,559 ) X (50 CU. FT. ) = 77,950 CU. | | FT. OF COMBUSTION AIR REQUIRED. THE CUBIC FOOTAGE OF | | THE RESTAURANT ON P1.2 IS SHOWN AS 94,880 AND ALSO AS | | 81,900 BEING DIVIDED BY 50 CU.FT. I DO NOT KNOW HOW YOU | | ARRIVED AT YOUR BTU PARAMETERS FOR THE COMBUSTION AIR. | | CLARIFY. | | 6) THE VENTING OF THE TANKLES WATER HEATRS SHALL COMPLY | | WITH THE APPROPRIATE TABLE FROM FGC SEC.504 AND TABLE | | 504.2 FOR THE APPLICABLE TYPE OF VENT MATERIAL BEING | | USED OR SUBMIT THE MANUFACTURER'S INSTALLATION DETAILS | | FOR THE VENTING OF MULTIPLE UNITS. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2015-04-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-14 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-04-14 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-03-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-12-30 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-12-30 |
Time |
15:51 |
Sent To |
|
|
Notes |
2015-03-02 15:20:50 | APPROVED BY HPB WITH CLEAR GLAZING. | 2014-12-30 15:53:31 | NOT CLEAR IF ORIGINAL WINDOW OPENINGS ARE BEING | | MODIFIED. FRAME COLOR, GLAZING COLOR? ADDITIONAL | | INFORMATION IS NEEDED INCLUDING RESOLUTION OF | | APPLICATION THAT HAS BEEN SUBMITTED FOR HEARIGN BY THE | | HISTORIC PRESERVATION BOARD ON 1/27. QUESTIONS CONTACT | | FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER | | AT (561) 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-06-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-24 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-05-12 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-04-27 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-03-24 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-01-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-01-27 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2014-12-05 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2015-03-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-03-16 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-03-16 |
Time |
16:29 |
Sent To |
|
|
Notes |
2015-03-16 16:31:58 | P. B. C. IMPACT FEE ASSESSMENT: | | MU-2015-5863 | | RECEIPT: 2015-0317-97 | | $178.08 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-12-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-19 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-19 |
Time |
16:56 |
Sent To |
|
|
Notes |
2014-12-19 16:56:05 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
rcaranci |
Date |
2015-06-23 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rcaranci |
Date |
2015-06-23 |
Time |
16:23 |
Sent To |
Z |
|
Notes |
2015-06-23 16:24:39 | WITH PROVISOS: | | | | A SEPARATE LANDSCAPE PERMIT SHALL BE SUBMITTED WITH | | COST ESTIMATE THAT ADDRESSES ALL THE FOLLOWING ITEMS: | | | | 1. PARKING SPACE IS NOT FUNCTIONAL WEST OF PROPOSED | | DUMPSTER, CONVERT TO LANDSCAPE AREA, COMPLETE CLUSIA | | HEDGE. | | | | 2. WHEEL STOPS MUST BE PROVIDED TO PROTECT LANDSCAPE | | AREAS PER CODE. | | | | 3. REMOVE INVASIVE EXOTIC SCHEFFLERA TREE AND REPLACE | | WITH SHADE OR FLOWERING TREE. | | | | 4. ADJUST SITE PLAN TO MATCH CHANGES |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2015-06-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-06-15 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-06-15 |
Time |
11:02 |
Sent To |
|
|
Notes |
2015-06-15 15:38:04 | PASS PROVISO | | 1) KITCHEN HOODS ARE NOT PART OF THIS REVIEW. | | HOODS REQUIRE SEPARATE APPLICATION, PLANS AND PERMIT | | 2) PROVIDE A DETAIL FROM THE ENGINEER ON CURB TO ROOF | | AND RTU TO CURB TIE DOWN, SHOW TYPE AND SIZE OF | | ANCHOR USED. PER SECTION 301.12 WIND RESISTANCE | | 2010 FBC (M) | | 3) CALL IN INSPECTION BEFOR RTU IS INSTALLED SO | | INSPECTOR CAN SEE SECURE STRAP AND TEX SCREWS. | | 4) REFER TO SECTION 503.2.4.4 SHUTOFF DAMPER CONTROLS | | 2010 FLORIDA ENERGY CODE | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-04-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-04-27 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-04-27 |
Time |
13:21 |
Sent To |
|
|
Notes |
2015-04-27 14:43:19 | PLAN DENIED | | 1) PROVIDE ENERGY CALCULATION WITH THE PLAN | | PER SECTION 503.2.1CALCULATION OF HEATING AND COOLING | | 2010 FLORIDA ENERGY CODE 2010 | | 2) REFER TO SECTION 304.1 GENERAL PROVIDE | | INSTALLATION INSTRUCTION FOR TUSCANY | | WOOD FUELED BBQ | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-01-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-01-05 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-01-05 |
Time |
12:15 |
Sent To |
|
|
Notes |
2015-01-05 12:19:49 | PASS PROVISO | | 1) REFER TO SECTION 304.11 GUARDS 2010 FBC (M) | | 2) REFER TO SECTION 503.2.5.4 SHUTOFF DAMPER CONTROLS | | 2010 FLORIDA ENERGY CODS | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-06-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-10 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-10 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-04-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-19 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-19 |
Time |
06:06 |
Sent To |
|
|
Notes |
2015-04-19 09:22:20 | 1) SUBMIT MANUF. SPECIFICATIONS FOR ALL GAS | | APPLIANCES/EQUIPMENT.ALL EQUIPMENT SHALL BE LISTED AND | | LABELED PER THE 2010 FUEL GAS CODE SEC.301.3. THE | | NARRATIVE RESPONSE REFERS TO SHT. QF 101FOR GAS | | EQUIPMENT AND SPECIFICATIONS. THERE IS NO SHT. QF 101. | | CLARIFY. | | 2) SUBMIT VENTING DETAILS FOR THE TANKLESS WATER | | HEATERS. THE TANKLESS WATER HEATERS ARE DIRECT VENT | | APPLIANCES AND THE VENTING IS USUALLY SHOWN IN THE | | MANUFACTURER'S INSTALLATION MANUAL. SUBMIT THE VENT | | DETAILS FROM THE MANUFACTURER.THE NARRATIVE RESPONSE | | STATES TO SEE SHT.P0.2 FOR WATER HEATER VENT | | DETAIL.THERE IS NO VENT DETAIL ON P0.2, JUST A CLOUDED | | EMPTY BOX. WPB AMEND. TO 2010 FBC SEC. 107.3.5.1.5. | | 3) SUBMIT MANUF. SPECIFICATION SHEETS FOR THE VENTLESS | | GAS REGULATORS. THE NARRATIVE RESPONSE REFERS TO SHT. | | P1.1B & ATTACHED CUT SHEET.THERE IS NO ADDITIONAL | | INFORMATION ON SHT.P1.1B & NO ATTACHED CUT SHEET. | | CLARIFY. | | 4) THE BTU LOAD OF THE APPLIANCES LISTED ON SHT. P1.2 | | AND SHT.P0.3 DO NOT CORRELATE. I HAVE ADDED THE BTU | | LOAD A FEW TIMES ON SHT. P1.2 AND THE TOTAL BTU LOAD I | | CALCULATED IS 1,559,000. CLARIFY. | | 5) SHT. P1.2 - PLEASE EXPLAIN HOW YOU ARRIVED AT THE | | CUBIC FOOTAGE OF 94,880 FOR THE RESTAURANT. IT IS | | UNCLEAR TO ME HOW YOU ARRIVED AT YOUR COMBUSTION AIR | | CALCULATIONS. IN ACCORDANCE WITH THE STANDARD METHOD IN | | THE 2010 FGC SEC.304.5.1, 50 CU. FT. OF COMBUSTION AIR | | IS REQUIRED FOR EACH 1,000 BTU OF THE APPLIANCE RATING. | | TAKING THE TOTAL BTU LOAD FROM COMMENT #4, 1,559,000 | | DIVIDED BY 1000 = (1,559 ) X (50 CU. FT. ) = 77,950 CU. | | FT. OF COMBUSTION AIR REQUIRED. THE CUBIC FOOTAGE OF | | THE RESTAURANT ON P1.2 IS SHOWN AS 94,880 AND ALSO AS | | 81,900 BEING DIVIDED BY 50 CU.FT. I DO NOT KNOW HOW YOU | | ARRIVED AT YOUR BTU PARAMETERS FOR THE COMBUSTION AIR. | | CLARIFY. | | 6) THE VENTING OF THE TANKLES WATER HEATRS SHALL COMPLY | | WITH THE APPROPRIATE TABLE FROM FGC SEC.504 AND TABLE | | 504.2 FOR THE APPLICABLE TYPE OF VENT MATERIAL BEING | | USED OR SUBMIT THE MANUFACTURER'S INSTALLATION DETAILS | | FOR THE VENTING OF MULTIPLE UNITS. | | 7) SHT. P0.2 - THE SANITARY RISER AS DRAWN DOES NOT | | COMPLY WITH 2010 FPC SEC. 909 FOR A WET VENT SYSTEM.THE | | WATER CLOSETS SHALL BE INDIVIDUALLY VENTED OR THE | | SYSTEM SHALL BE DESIGNED AS A CIRCUIT VENT IN | | COMPLIANCE WITH FPC SEC.911. | | 8) THE MOP SINK IS SHOWN WITH A VENT ON THE PLAN VIEW | | DRAWING ( P1.1A ) BUT NOT ON THE RISER. CLARIFY. | | 9) THE STAFF RESTROOM CLEARLY OPENS INTO THE FOOD PREP | | AREA. THERE IS A DOUGH PREP AREA ALMOST DIRECTLY IN | | FRONT OF IT.TOILET ROOMS SHALL NOT OPEN DIRECTLY INTO A | | ROOM USED FOR THE PREPARATION OF FOOD FOR SERVICE TO | | THE PUBLIC PER THE 2010 FBC SEC.1210.5. | | 10) SUBMIT A COMPLETE FOOD SERVICE EQUIPMENT PLAN.WPB | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-12-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-12-22 |
Time |
06:06 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-12-21 |
Time |
09:09 |
Sent To |
|
|
Notes |
2014-12-22 05:18:26 | 1) SHT.A4.0 - DETAIL #1 - STAFF R.R.- THE HEIGHT OF THE | | GRAB BAR ABOVE THE FINISH FLOOR SHALL BE MEASURED TO | | THE TOP OF THE GRIPPING SURFACE, NOT TO THE CENTERLINE | | OF THE BAR AS SHOWN.2010 FL. ACCESS. CODE SEC.609.4. | | 2) LIFE SAFETY PLAN - INDICATE THE PREVIOUS OCCUPANCY | | ON THE PLAN. WPB AMEND. TO 2010 FBC SEC.107.2.1.. SEE | | THE BUILDING PLAN REVIEW COMMENT. | | 3) A SERVICE SINK IS REQUIRED PER TABLE 403.1. | | 4) SUBMIT MANUFACTURER SPECIFICATION SHEETS AND | | INSTALLATION MANUAL FOR THE TANKLESS WATER HEATERS. THE | | TANKLESS WATER HEATERS SHALL BE LISTED AND LABELED PER | | THE 2010 FL. GAS CODE SEC. 301.3. | | 5) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | THE GAS APPLIANCES/EQUIPMENT. ALL EQUIPMENT SHALL BE | | LISTED AND LABELED PER SEC. 301.3 OF THE 2010 FGC. | | 6) SHT. P0.2 - THE SANITARY RISER DOES NOT COMPLY WITH | | SEC.909 OF THE FL. PLUMBING CODE FOR THE NUMBER AND | | TYPE OF FIXTURES PERMITTED ON A WET VENT. | | 7) SHT.P1.1A - A FLOOR DRAIN IS SHOWN IN THE WARE | | WASHING AREA (#113) BUT IS NOT SHOWN ON THE GREASY | | WASTE RISER ON P0.2.CLARIFY. | | 8) SHT.P1.1A - SHOW THE INDIRECT WASTE FROM FIXTURE #7 | | TO THE FLOOR DRAIN ON RISER P0.2. | | 9) SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE | | TANKLESS WATER HEATERS & ALL THE GAS APPLIANCES ON THE | | FIRST FLOOR. 201 FL. GAS CODE SEC.304. | | 10) SUBMIT VENTING DETAILS FOR THE TANKLESS WATER | | HEATERS. 201 FGC SEC.503.THE PLUMBING PLANS REFER TO | | THE MECHANICAL SHEETS FOR DETAILS BUT THERE IS JUST A | | PLAN VIEW WITH NO DETAILS. | | 11) SUBMIT MANUF. SPECS FOR THE VENTLESS GAS | | REGULATORS. WPB AMEND. TO 2010 FBC SEC.107.2.1, FGC | | SEC.410.0. | | 12) SHOW THE INCREMENTAL BTU/CFH LOAD ON THE GAS PIPING | | SYSTEMFROM THE ENTRANCE METER TO THE FURTHEST OUTLET. | | 13) WHERE IS PAGE 2 OF 2 FOR THE GREASE INTERCEPTOR | | DETAILS.? | | 14) THE GREASE TRAPS APPEAR TO BE LOCATED ON LOT 6. IS | | THIS PROPERTY OWNED BY THE RESTAURANT? | | 15) PROVIDE A LEGEND FOR THE HOT, COLD, HOT WATER | | RETURN AND THE TEMPERED WATER. THE RISER SHOWS THE | | INDIVIDUAL WATER IDENTIFIED WITH DOTS AND DASHES.WPB | | AMEND. TO 2010 FBC SEC.107.2.1 | | 16) PROVIDE INFORMATION/DETAILS FOR THE REGULATOR VENT | | FOR THE TANKLESS WATER HEATERS. WPB AMEND. TO 2010 FBC | | SEC.107.2.1.COMPLY W/ 2010 FGC SEC.410.3.1. | | 17) TOILET ROOMS SHALL NOT OPEN DIRECTLY INTO A ROOM | | USED FOR THE PREPARATION OF FOOD FOR SERVICE TO THE | | PUBLIC. 2010 FL. BLDG. CODE. SEC.1210.5. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2015-07-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-01 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-01 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2015-06-29 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-29 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-29 |
Time |
12:05 |
Sent To |
|
|
Notes |
2015-06-29 15:26:26 | 1ST REVIEW: FBC 2010 | | | | THERE ARE 48 FILES BUT YOU HAVE SUBMITTEED SIGNATURE | | DOCUMENTS AND REPORTS FOR ONLY 10 FILES. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | 2015-06-16 15:18:52 | PEDDS SUBMITTED 6/16/15 WAITING ON PASSED PLAN REVIEW. | | CP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2015-06-24 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2015-06-24 |
Time |
14:23 |
Sent To |
|
|
Notes |
2015-06-24 14:24:45 | PER FRIEDERIKE MITTNER: OK TO PASS ZONING REVIEW | | BECAUSE IT WAS PENDING SUBMITTAL OF A LANDSCAPE PLAN | | WHICH HAS NOW BEEN SUBMITTED AND REVIEWED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2015-04-29 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-29 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-04-14 |
Time |
16:05 |
Sent To |
|
|
Notes |
2015-04-14 16:05:44 | STILL MISSING LANDSCAPE PLAN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-12-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-12-30 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-12-30 |
Time |
15:53 |
Sent To |
|
|
Notes |
2014-12-30 16:04:39 | VALUE OF PERMIT $336,000 EXCEEDS 50% OF $268,897 VALUE | | OF IMPROVEMENT. REQUIRES A LANDSCAPE PLAN. | 2014-12-16 18:10:06 | 12/16/14 |
|
|
|