Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-01-16 Cont ID  
Sent By jwitmer Date 2015-01-16 Time 16:07 Rev Time 0.00
Received By jwitmer Date 2015-01-16 Time 11:59 Sent To  
Notes
2015-01-16 15:59:55BUILDING PLAN REVIEW
 PERMIT: 14120084
 ADD: 401 S. DIXIE HWY. SUITE # 302
 CONT: IBIS BUILDING
 TEL: (561)318-8408
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: FRI. JAN. 16/2015
 ACTION: BUILDING PROVISO
  
 REVISON IS REQUIRED, SEE SHEET A-1.0 BREAK AREA. THE
 PLANS SHOW A SIDE APPROACH, THE SINK NEED TO BE
 CENTERED IN THE 48" OF THE SIDE APPROACH SO THE SINK IS
 NOT BEHIND OR IN FRONT OF THE WHEEL CHAIR. 2010 FL
 ACCESS. CODE 606.2 & 305.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-05 Cont ID  
Sent By jwitmer Date 2014-12-05 Time 11:36 Rev Time 0.00
Received By jwitmer Date 2014-12-05 Time 13:18 Sent To  
Notes
2014-12-05 11:36:53BUILDING PLAN REVIEW
 PERMIT: 14120084
 ADD: 401 S. DIXIE HWY. SUITE # 302
 CONT: IBIS BUILDING
 TEL: (561)318-8408
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. DEC. 05/2014
 ACTION: DENIED.
  
 1) SHEET A-1.0 THE DOOR SCHEDULE LIST THE FRONT ENTRY
 DOORS AS TYPE E, A EXISTING DOOR. THE LIFE SAFETY
 SHEETS INDICATE THIS TO BE A 1 HOUR FIRE RATED WALL,
 2010 FBC-B TABLE 715.4 OPENING PROTECTIVES A 1 HR. FIRE
 RATED CORRIDORR REQUIRES A 20 MIN. OPENING PROTECTIVE.
  
 2) SHEET A-1.0 THE FLOOR PLANS IDENTIFIES THE WINDOWS
 WITH A IDENTIFICATION TAG # 1. THE DOOR AND WINDOW
 SCHEDULE UNDER THE HEADING # 1 IDENTIFIES WINDOW & DOOR
 SCHEDULE IDENTIFIES THE WINDOWS TYPE AS A B3. SHEET
 A-2.0 IDENTIFIES THE WINDOW TYPE B3 AS A WOOD FRAMED
 DOOR WITH TEMPERED GLASS.
 THE WINDOW TYPE 1 IS NOT IDENTIFIED NOR DOES THE ISSUE
 OF THE GLAZING BEING A HAZARDOUS LOCATION. SEE 2010
 FBC-B 2406.4;
  
 6. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL
 ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF
 THE GLAZING IS WITHIN A 24-INCH (610 MM)
 ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED
 POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE
 GLAZING IS LESS THAN 60 INCHES (1524 MM)
 ABOVE THE WALKING SURFACE.
  
 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL,
 OTHER THAN IN THOSE LOCATIONS DESCRIBED IN PRECEDING
 ITEMS 5 AND 6, WHICH MEETS ALL OF THE
 FOLLOWING CONDITIONS:
 7.1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9
 SQUARE FEET (0.84 M2);
 7.2. EXPOSED BOTTOM EDGE LESS THAN 18 INCHES (457 MM)
 ABOVE THE FLOOR;
 7.3. EXPOSED TOP EDGE GREATER THAN 36 INCHES (914 MM)
 ABOVE THE FLOOR; AND
 7.4. ONE OR MORE WALKING SURFACE(S) WITHIN 36 INCHES
 (914 MM) HORIZONTALLY OF THE PLANE OF THE GLAZING.
  
 3) SHEET A-1.0 BREAK ROOM SINK DOES NOT SHOW COMPLIANCE
 FOR A FRONTAL APPROACH MEETING THE FOLLOWING
 ACCESSIBILITY ISSUE:
 2010 FBC-ACCESSIBILIITY 606;
 606.1 GENERAL..
 606.2 CLEAR FLOOR SPACE.
 606.3 HEIGHT.
 606.4 FAUCETS.
 606.5 EXPOSED PIPES AND SURFACES.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-01-16 Cont ID  
Sent By skennedy Date 2015-01-16 Time 16:12 Rev Time 0.00
Received By skennedy Date 2015-01-16 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-12-22 Cont ID  
Sent By dhayes Date 2014-12-22 Time 13:51 Rev Time 0.00
Received By dhayes Date 2014-12-18 Time 13:55 Sent To  
Notes
2014-12-22 13:50:3212/22/2014
 PROJECT: 401 S. DIXIE STE302
 PERMIT#: 14120085
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.1ST
 ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) 505.2 LIGHTING CONTROLS (MANDATORY). LIGHTING
 SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS REQUIRED IN
 SECTIONS 505.2.1, 505.2.2, 505.2.3 AND 505.2.4.
  
 2) FLOOR BOX SHALL BE APPROVED FOR INSTALLATION IN A
 FIRE RATED FLOORE/CEILING. NEC 110.3(B)
 A.) FBC 713.4.1 FIRE-RESISTANCE-RATED ASSEMBLIES.
 PENETRATIONS OF THE FIRE-RESISTANCE-RATED FLOOR,
 FLOOR/CEILING ASSEMBLY OR THE CEILING MEMBRANE OF A
 ROOF/CEILING ASSEMBLY SHALL COMPLY WITH SECTIONS
 713.4.1.1 THROUGH 713.4.1.4. PENETRATIONS IN HORIZONTAL
 SMOKE BARRIERS SHALL ALSO COMPLY WITH 713.5.
 B.) FBC 713.4.1.1 THROUGH PENETRATIONS. THROUGH
 PENETRATIONS OF FIRE-RESISTANCE-RATED HORIZONTAL
 ASSEMBLIES SHALL COMPLY WITH SECTION 713.4.1.1.1 OR
 713.4.1.1.2.
 C.) FBC 713.4.1.1(3) PENETRATIONS BY LISTED ELECTRICAL
 BOXES OF ANY MATERIAL, PROVIDED SUCH BOXES HAVE BEEN
 TESTED FOR USE IN FIRE-RESISTANCE-RATED ASSEMBLIES AND
 INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED
 IN THE LISTING.
  
 3) MULTIWIRE CIRCUITS, NOT PERMITTED. INDIVIDUAL
 PARTITIONS OR GROUPS OF INTERCONNECTED INDIVIDUAL
 PARTITIONS SHALL NOT CONTAIN MULTIWIRE CIRCUITS.NEC
 605.8 (D)
 A.) WIRED PARTITIONS THAT ARE FIXED (SECURED TO
 BUILDING SURFACES) SHALL BE PERMANENTLY CONNECTED TO
 THE BUILDING ELECTRICAL SYSTEM BY ONE OF THE WIRING
 METHODS OF CHAPTER 3. MULTIWIRE BRANCH CIRCUITS
 SUPPLYING POWER TO THE PARTITION SHALL BE PROVIDED WITH
 A MEANS TO
 DISCONNECT SIMULTANEOUSLY ALL UNGROUNDED CONDUCTORS AT
 THE PANELBOARD WHERE THE BRANCH CIRCUIT ORIGINATES. NEC
 605.6 FIXED-TYPE PARTITIONS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 SEE LINK: HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS
 /SITES/33/2013/09/APPLICATION_RESUBMITTAL_FORM_04132010
 .PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-12-03 Cont ID  
Sent By pleduc Date 2014-12-03 Time   Rev Time 0.00
Received By pleduc Date 2014-12-03 Time 14:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-01-16 Cont ID  
Sent By skennedy Date 2015-01-16 Time 16:13 Rev Time 0.00
Received By skennedy Date 2015-01-09 Time 14:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-27 Cont ID  
Sent By skennedy Date 2014-12-27 Time 10:30 Rev Time  
Received By skennedy Date 2014-12-02 Time   Sent To  
Notes
2014-12-03 06:11:51INCOMING SENT TO B01 BOX .

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-12-27 Cont ID  
Sent By skennedy Date 2014-12-27 Time 10:30 Rev Time 0.00
Received By skennedy Date 2014-12-18 Time 13:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-12-09 Cont ID  
Sent By tklarge Date 2014-12-06 Time 03:52 Rev Time 0.00
Received By tklarge Date 2014-12-06 Time 06:21 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved