Plan Review Details - Permit 14110936
Plan Review Stops For Permit 14110936 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-09-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-24 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-23 |
Time |
18:19 |
Sent To |
|
|
Notes |
2015-09-24 07:58:02 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | REVISION DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NEW STRUCTURAL SHEET S-10 FOR FORMED AND POURED | | CONCRETE STAIRS WAS RE-SUBMITTED WITH THIS REVISION. | | THE SAME S-10 DRAWINGS WERE SUBMITTED WITH ANOTHER | | REVISION (# 15090378). SUBMIT TWO SETS OF REVISED | | ARCHITECTURAL DRAWINGS THAT SHOW THE LOCATION, | | ELEVATIONS AND ORIENTATION OF THE REVISED STAIRS. FBC | | 107.2.1 | | | | 2) SUBMIT TWO SETS OF REVISED ARCHITECTURAL DRAWINGS | | THAT SHOW THE ELEVATOR AND ELEVATOR EQUIPMENT. THE | | ELEVATOR AND EQUIPMENT ARE REQUIRED TO COMPLY WITH CITY | | OF WEST PALM BEACH FLOOD ORDINANCE AND FEMA | | REQUIREMENTS. FBC 107.2.1 & FBC-R322 | | | | 3) SEE COMMENTS FROM FIRST REVIEW. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
07:11 |
Sent To |
Z |
|
Notes |
2014-12-10 09:27:09 | BUILDING PROVISO | | THE ELEVATOR ENCLOSURE IS LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (A5 FLOOD ZONE ) AND IS REQUIRED TO COMPLY | | WITH FBC-R322 AND ASCE 24-05. THEREFORE, THE FOLLOWING | | ARE ITEMS ARE REQUIRED: | | 1) THE ENCLOSURE IS REQUIRED TO BE DESIGNED TO RESIST | | FLOOD LOADS (I.E., HYDROSTATIC, HYDRODYNAMIC, | | FLOOD-BORNE DEBRIS, EROSION AND SCOUR). PROVIDE A | | LETTER OF AFFIRMATION FROM THE ENGINEER. | | 2) THE ELEVATOR EQUIPMENT SHALL BE LOCATED ABOVE THE | | 7.5' BASE FLOOD ELEVATION. IF EQUIPMENT MUST BE LOCATED | | BELOW THE BFE, IT SHALL BE PROTECTED USING FLOOD | | DAMAGE-RESISTANT COMPONENTS. | | 3) THE ELEVATOR CAB MUST BE EQUIPPED WITH CONTROLS THAT | | PREVENT THE CAB FROM DESCENDING INTO FLOOD-WATERS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-09-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-24 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-09 |
Time |
09:44 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-12-11 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-12-11 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-11-26 |
Time |
10:44 |
Sent To |
|
|
Notes |
2014-12-11 09:55:11 | 12/11/14 - DENIED, FILED IN SMALL BIN UNDER W. DK | 2014-11-26 10:45:32 | INCOMING SENT TO R. MCDOUGALS' DESK . JW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-24 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2015-09-10 |
Time |
10:16 |
Sent To |
|
|
Notes |
2015-09-10 13:41:07 | 9/10/15 SENT TO RM IN BUILDING. DK | | | | | 2015-09-10 13:40:07 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 9/10/15 | | | | REVISION SUBMITTED WAS THE ADDITION OF SHEET S-10. THE | | FOLLOWING ZONING COMMENTS FROM 12/11/14 WERE NOT | | ADDRESSED: | | | | 1. PLEASE PROVIDED REVISED ELEVATIONS INDICATING HEIGHT | | OF THE ELEVATOR STRUCTURE. HEIGHT SHALL NOT EXCEED 30 | | FEET (ZLDR SEC. 94-72(A)(3)), UNLESS OTHERWISE | | PERMITTED UNDER ZLDR SEC. 94-306, HEIGHT EXCEPTIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-12-11 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-12-11 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-12-11 |
Time |
09:10 |
Sent To |
|
|
Notes |
2014-12-11 09:52:00 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 12/11/14 | | | | 1. PLEASE PROVIDED REVISED ELEVATIONS INDICATING HEIGHT | | OF THE ELEVATOR STRUCTURE. HEIGHT SHALL NOT EXCEED 30 | | FEET (ZLDR SEC. 94-72(A)(3)), UNLESS OTHERWISE | | PERMITTED UNDER ZLDR SEC. 94-306, HEIGHT EXCEPTIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy