Plan Review Details - Permit 14110820
Plan Review Stops For Permit 14110820
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-15 Cont ID  
Sent By jwitmer Date 2014-12-15 Time 07:41 Rev Time 0.00
Received By jwitmer Date 2014-12-11 Time 15:43 Sent To  
Notes
2014-12-11 16:01:40BUILDING PLAN REVIEW
 PERMIT: 14110820
 ADD: 224 DATURA ST
 CONT: SPECIAL FORCES CONSTRUCTION
 TEL: (772)334-2990
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. DEC. 15/ 2014
 ACTION: PASSED
  
 THIS PERMIT WILL ONLY COVER THE EXTERIOR DEMO OF THE
 LOOSE EXTERIOR STUCCO TO ALLOW A STRUCTURAL ENGINEER TO
 VERIFY THERE IS NO STRUCTURAL DAMAGE. IF NO STRUCTURAL
 DAMAGE THE STRUCTURAL ENGINEER WILL RIGHT A REPORT ON
 HOW THE REPAIRS ARE TO TAKE PLACE.
  
 A SECOND PERMIT WILL BE NECESSARY FOR THE STUCCO REPAIR
 THE VALUE OF THE JOB ($29,000.00) WILL THEN BE APPLIED
 TO THIS PERMIT. NOTE $75.00 OF THE INSPECTION ONLY
 PERMIT WILL BE APPLIED TO THIS PERMIT PLUS A CREDIT OF
 $37.60 DUE TO OVER PAYMENT OF A INSPECTION ONLY PERMIT>
  
 IF THERE IS STRUCTURAL DAMAGE, THIS BUILDING QUALIFIES
 AS A THRESHOLD BUILDING.
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA
 AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS.
  
 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 THRESHOLD INSPECTOR:
 WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE. THE THRESHOLD INSPECTION FORMS ARE TO BE FILLED
 OUT BY ALL INTERESTED PARTIES AND RETURN TO THE
 BUILDING DEPARTMENT BEFORE THE ISSUANCE OF THIS PERMIT.
 CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR
 PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION
 BEFORE THE PERMIT MAY BE ISSUED.
  
 THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
 1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
 THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN
 CONRAD: [email protected]
  
 2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME'
 OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE
 RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS
 SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE
 WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED,
 AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
 CONTACT KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-11-25 Cont ID  
Sent By jwitmer Date 2014-11-25 Time 16:10 Rev Time 0.00
Received By jwitmer Date 2014-11-25 Time 15:50 Sent To Z
Notes
2014-11-25 16:10:23BUILDING PLAN REVIEW
 PERMIT: 14110820
 ADD: 224 DATURA ST
 CONT: SPECIAL FORCES CONSTRUCTION
 TEL: (772)334-2990
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 25/ 2014
 ACTION: DENIED
  
 1) REPAIRS 2010 FBC-EXISTING TO DETRMINE IF THERE IS
 STRURTURAL DAMAGE OR IF THIS IS JUST COSMETIC PLEASE
 SHOW COMPLIANCE WITH 506.2.2.1 EVALUATION.
 THE BUILDING SHALL BE EVALUATED BY A REGISTERED DESIGN
 PROFESSIONAL, AND THE EVALUATION FINDINGS SHALL BE
 SUBMITTED TO THE CODE OFFICIAL. THE EVALUATION SHALL
 ESTABLISH WHETHER THE DAMAGED BUILDING, IF REPAIRED TO
 ITS PREDAMAGED STATE, WOULD COMPLY WITH THE PROVISIONS
 OF THE CODES THAT WERE IN EFFECT WHEN THE BUILDING WAS
 PERMITTED.
  
 2) PLEASE PROVIDE HOW ACCESS TO THE DAMAGED AREAS OF
 WALLS WILL BE ACCESSED, BY SCAFFOLDING, OR SWING STAGE?
 DOES ANY OF THE DAMAGED AREAS OCCUR OVER THE RIGHT OF
 WAY?
  
 3) 2010 FBC-B 3202.5 SIDEWALK OR STREET OBSTRUCTIONS.
 UNLESS ALLOWED BY THE APPLICABLE GOVERNING AUTHORITY
 HAVING JURISDICTION OF THE RIGHT-OF-WAY OR PUBLIC
 PROPERTY, PUBLIC PROPERTY SHALL BE MAINTAINED CLEAR OF
 ANY AND ALL OBSTRUCTIONS, INCLUDING AMONG OTHERS,
 SCAFFOLDING , POSTS, COLUMNS, OR OTHER IMPEDEMENTS. IF
 WORK IS OCCURING WITHIN THE RIGHT OF WAY ENGINEERING
 PERMITS WILL ALSO NEED TO BE OBTAINED.
  
 4) 2010 FBC-B 3306.2 WALKWAYS. A WALKWAY SHALL BE
 PROVIDED FOR PEDESTRIAN TRAVEL IN FRONT OF EVERY
 CONSTRUCTION AND DEMOLITION SITE UNLESS THE APPLICABLE
 GOVERNING AUTHORITY AUTHORIZES THE SIDEWALK TO BE
 FENCED OR CLOSED. WALKWAYS SHALL BE OF SUFFICIENT WIDTH
 TO ACCOMMODATE THE PEDESTRIAN TRAFFIC, BUT IN NO CASE
 SHALL THEY BE LESS THAN 4 FEET (1219 MM) IN WIDTH.
 WALKWAYS SHALL BE PROVIDED WITH A DURABLE WALKING
 SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN ACCORDANCE
 WITH CHAPTER 11 AND SHALL BE DESIGNED TO SUPPORT ALL
 IMPOSED LOADS AND IN NO CASE SHALL THE DESIGN LIVE LOAD
 BE LESS THAN 150 POUNDS PER SQUARE FOOT (PSF) (7.2
 KN/M2)
  
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2014-12-22 Cont ID  
Sent By cranford Date 2014-12-22 Time 10:41 Rev Time 0.00
Received By cranford Date 2014-12-22 Time 10:39 Sent To I
Notes
2014-12-22 10:40:54SPOKE WITH TAMMY FROM SPECIAL FORCES ON DEC 19TH AND
 SHE EXPLAINED THAT THEY WILL BE USING SWING SCAFFOLDING
 FOR THE INSPECTION AND DO NOT NEED TO PLACE SCAFFOLDING
 IN THE RIGHT-OF-WAY. IF THE SIDEWALK IS NOT GOING TO BE
 OBSTRUCTED, THEN A RIGHT-OF-WAY PERMIT IS NOT NEEDED.
  
 KELLY CRANFORD, PE

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2014-12-17 Cont ID  
Sent By cranford Date 2014-12-17 Time 15:44 Rev Time 0.00
Received By cranford Date 2014-12-17 Time 15:42 Sent To I
Notes
2014-12-17 15:44:12PLEASE SUBMIT APPLICATIONS FOR A CITY RIGHT-OF-WAY
 PERMIT FOR OBSTRUCTING THE SIDEWALK DURING THE
 INSPECTION. APPLICATION FORMS CAN BE FOUND AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
 (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES)

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-12-11 Cont ID  
Sent By fmittner Date 2014-12-11 Time 14:40 Rev Time 0.00
Received By fmittner Date 2014-12-11 Time 14:40 Sent To  
Notes
2014-12-11 14:41:23STUCCO REPAIR MUST MATCH EXISTING IN TEXTURE AND COLOR.
 PERMIT RETURNED TO JIM WITMER.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-17 Cont ID  
Sent By cranford Date 2014-12-17 Time 15:45 Rev Time 0.00
Received By cranford Date 2014-11-21 Time 08:01 Sent To  
Notes
2014-11-22 08:02:41SENT TO J WITMER

Review Stop Z ZONING
Rev No 1 Status P Date 2014-12-11 Cont ID  
Sent By aaponte Date 2014-12-11 Time 09:45 Rev Time 0.00
Received By aaponte Date 2014-12-11 Time 09:45 Sent To HIST
Notes
***NONE***