Plan Review Details - Permit 14110003
Plan Review Stops For Permit 14110003 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-11-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-25 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-25 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-11-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-24 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-24 |
Time |
12:08 |
Sent To |
|
|
Notes |
2014-11-24 12:23:42 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | NOTE: E-MAIL SENT ON 11/21/14 DOESN'T ADDRESS THE ITEMS | | REQUESTED. ONLY SUBMITED THE PRODUCT APPROVAL | | FL11903-R1 COVER PAGES. THIS IS THE SAME INFORMATION | | THAT WAS ORIGINALLY SUBMITTED. PLEASE SUBMITT THE | | INFORMATION REQUESTED BELOW: | | | | | | 1- METAL ROOFING FLORIDA PRODUCT APPROVAL FL11903-R1 | | SUBMITTED: ONLY THE COVER PAGE WAS SUBMITTED. PROVIDE | | TWO COPIES OF THE SPECIFIC METAL ROOFING SYSTEM TO BE | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. | | | | 2- MODIFIED BITUMEN ROOF SYSTEM FLORIDA PRODUCT | | APPROVAL FL10497-R2 SUBMITTED: | | A) PROVIDE COMPLETE INFORMATION SHOWING WHICH APPROVED | | SYSTEM IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2010 | | FBC-RESIDENTIAL. | | | | B) IF SELECTED SYSTEM DOESN'T MEET THE REQUIRED DESIGN | | PRESSURES, THEN NEED TO PROVIDE TWO SIGNED AND SEALED | | RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER | | AND CORNER AREAS AS REQUIRED BY NOTE #8 OF FLORIDA | | PRODUCT APPROVAL FL10497 SUBMITTED. | | ***NOTE: SEE NOTE #9 IF FULLY BONDED ASSEMBLY IS USED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-11-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-19 |
Time |
18:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-19 |
Time |
17:45 |
Sent To |
|
|
Notes |
2014-11-19 18:27:25 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- METAL ROOFING FLORIDA PRODUCT APPROVAL FL11903-R1 | | SUBMITTED: ONLY THE COVER PAGE WAS SUBMITTED. PROVIDE | | TWO COPIES OF THE SPECIFIC METAL ROOFING SYSTEM TO BE | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. | | | | 2- MODIFIED BITUMEN ROOF SYSTEM FLORIDA PRODUCT | | APPROVAL FL10497-R2 SUBMITTED: | | A) PROVIDE COMPLETE INFORMATION SHOWING WHICH APPROVED | | SYSTEM IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2010 | | FBC-RESIDENTIAL. | | | | B) IF SELECTED SYSTEM DOESN'T MEET THE REQUIRED DESIGN | | PRESSURES, THEN NEED TO PROVIDE TWO SIGNED AND SEALED | | RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER | | AND CORNER AREAS AS REQUIRED BY NOTE #8 OF FLORIDA | | PRODUCT APPROVAL FL10497 SUBMITTED. | | ***NOTE: SEE NOTE #9 IF FULLY BONDED ASSEMBLY IS USED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-11-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-11-18 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-11-18 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-11-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-25 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-25 |
Time |
09:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-11-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-24 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-24 |
Time |
12:07 |
Sent To |
|
|
Notes |
2014-11-24 12:08:11 | E-MAIL FROM LILLIAN. JG. |
|
|
|
Account Summary | Usage Policy | Privacy Policy