Plan Review Details - Permit 14100830
Plan Review Stops For Permit 14100830
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-01 Cont ID  
Sent By shill Date 2014-12-01 Time 14:25 Rev Time 0.00
Received By shill Date 2014-12-01 Time 14:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-11-05 Cont ID  
Sent By shill Date 2014-11-05 Time 11:25 Rev Time 0.00
Received By shill Date 2014-11-05 Time 11:25 Sent To FIRE
Notes
2014-11-05 11:31:50****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC 2010
 107.2.1:
  
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES
 AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE
 QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL
 CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5).
  
 SEE ALSO FBC 107.2.1.4: QUALITY OF BUILDING PLANS:
  
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS
 FOR PLANS AND SPECIFICATIONS, IN
 ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF
 FLORIDA STATUTES.
  
 2. SEE ALSO 107.3.5, MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS. PLAN SUBMITTED IS NOT TO SCALE, DOES NOT
 HAVE ROOMS LABELED AS TO USE, DETAIL FOR PROPOSED WALL
 AND DOOR FRAMING NOT PROVIDED, OVERALL DIMENSIONS NOT
 SHOWN. PROVIDE AN ARCHITECTURAL QUALITY PLAN, TO SCALE,
 WHICH SHOWS PROPOSED IMPROVEMENT.
  
 3. AS IT APPEARS THAT YOU ARE ADDING BEDROOMS, IMPACT
 FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED (PER
 WILLIE SWOPE). PLEASE CALL 561-233-5025 FOR MORE
 INFORMATION.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-11-21 Cont ID  
Sent By pleduc Date 2014-11-21 Time 10:28 Rev Time 0.00
Received By dhayes Date 2014-11-21 Time 10:28 Sent To FIRE
Notes
2014-11-21 10:49:3011/21/2014
 PROJECT: BEDROOM WALL
 PERMIT#: 14100830
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 2ND ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL
 314 AND 315. PROVIDE OR VERIFY THE REQUIRED SMOKE
 DETECTORS IN THE LOCATIONS REQUIRED BY THE FBC-R314,
 315
  
 2) RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL
 SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE
 OUTLET.). NEC 210.52(A)(1) IT APPEARS AS THOUGH AN
 ADDITIONAL OUTLET IS REQUIRED IN THE NEW PARTITION.
 EITHER INDICATE A NEW OUTLET WILL BE INSTALLED OR
 INDICATE HOW THE EXISTING OUTLETS COMPLY WITH THE NEC
 210.52(A)(1)
  
 3) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER
 RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11
  
 4) AT LEAST ONE WALL SWITCH?CONTROLLED LIGHTING OUTLET
 SHALL BE INSTALLED IN EVERY HABITABLE ROOM AND
 BATHROOM. CLARIFY HOW THE INTENT OF NEC 210.70(A)(1)
 WILL BE MET.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-11-14 Cont ID  
Sent By dhayes Date 2014-11-14 Time 16:23 Rev Time 0.00
Received By dhayes Date 2014-11-14 Time 16:23 Sent To  
Notes
2014-11-14 16:32:2811/14/2014
 PROJECT: BEDROOM WALL
 PERMIT#: 14100830
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) MINIMUM ELECTRICAL PLAN REVIEW CRITERIA SHALL
 INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: WIRING,
 SERVICES, FEEDERS AND BRANCH CIRCUITS, OVERCURRENT
 PROTECTION, GFCIS, GROUNDING, WIRING METHODS AND
 MATERIALS, WPB AMENDMENTS TO FBC 107.3.5.1.2
  
 2) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL.
 WPB AMENDMENTS TO FBC 107.2.1
  
 3) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL
 314 AND 315
  
 4) RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL
 SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE
 OUTLET. 210.52(A)(1)
  
 5) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER
 RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-11-24 Cont ID  
Sent By pleduc Date 2014-11-24 Time   Rev Time 0.00
Received By pleduc Date 2014-11-21 Time 15:48 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-11-06 Cont ID  
Sent By pleduc Date 2014-11-06 Time   Rev Time 0.00
Received By pleduc Date 2014-11-06 Time 11:20 Sent To E
Notes
2014-11-06 11:36:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 THE SUBMITTED PLAN LACKS THE REQUIRED DETAIL REGARDING
 LIFE SAFETY SYSTEMS DEVICE LOCATIONS, INCLUDING BUT NOT
 LIMITED TO, SMOKE DETECTORS, SPRINKLER HEADS, AND FIRE
 ALARM DEVICES; BOTH EXISTING AND PROPOSED.
  
 WHAT IS THE PROPOSED OCCUPANCY TYPE, RESIDENTIAL,
 BUSINESS OR OTHER?
  
 THE ROOMS ARE NOT LABELED AND IS THE DRAWING THE ENTIRE
 SPACE OR JUST A PORTION OF A LARGER SPACE?
  
 A LIFE SAFETY PLAN IS NOT PROVIDED, INDICATING ALL
 OCCUPANCY LOADS, EXIT PATHS, EXITS SIGNS(IF REQUIRED
 FOR BUSINESS), EMERGENCY LIGHTS(IF REQUIRED FOR
 BUSINESS) AND EXIT DOORS.
  
 PLEASE ALSO REVIEW OTHER DEPARTMENT COMMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-01 Cont ID  
Sent By shill Date 2014-12-01 Time 14:26 Rev Time 0.00
Received By shill Date 2014-11-20 Time 10:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-11-14 Cont ID  
Sent By dhayes Date 2014-11-14 Time 16:32 Rev Time 0.00
Received By dhayes Date 2014-10-28 Time 13:26 Sent To  
Notes
2014-11-05 11:32:1211/5 TO FIRE
  
2014-10-28 13:26:54SENT TO BLDG. BOX <$5K. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-12-01 Cont ID  
Sent By dhayes Date 2014-11-14 Time 16:32 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2014-10-28 Cont ID  
Sent By jwitmer Date 2014-10-28 Time 13:27 Rev Time 0.00
Received By jwitmer Date 2014-10-28 Time 13:27 Sent To  
Notes
***NONE***