Plan Review Details - Permit 14100651
Plan Review Stops For Permit 14100651
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-04-28 Cont ID  
Sent By jwitmer Date 2015-04-28 Time 16:40 Rev Time 0.00
Received By jwitmer Date 2015-04-28 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-02-27 Cont ID  
Sent By jwitmer Date 2015-02-27 Time 14:46 Rev Time 0.00
Received By jwitmer Date 2015-02-27 Time 12:30 Sent To  
Notes
2015-02-27 14:46:29BUILDING PLAN REVIEW
 PERMIT: 14100651
 ADD: 526 NORTHWOOD
 CONT: K & M CONSTRUCTION
 TEL: (561)383-2817
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MAY 11, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 2ND REVIEW
 DATE: FRI. FEB. 27/ 2015
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) 2ND REQUEST, SEMI-COMPLIED. THE PLANS INDICATE A 146
 MPH WIND SPEED. THE PLANS DO NOT STATE IF THIS WIND
 SPEED IS IN VULT OR VASD. THE PRESSURES PROVIDED
 INDICATES A C EXPOSURE, TAKEN AT 30 FEET AND WORST CASE
 SCENARIO OR WALL ZONE 5 FOR 10 SQ. FT. THE PRESSURES
 WOULD EQUATE TO 132 MPH VASD NOT A 146MPH. 2010 FBC-B
 1609.1.5 & 1609.1.2.3.1.
  
 3) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4A) 2ND REQUEST. SHEET A-3 VARIOUS ELEVATIONS SHOW
 ORNATE ARCHITECTURAL FACADE WORK, THERE ARE NO DETAILS
 HOW THE FACADE WILL BE MADE OR SECURED TO THE BUILDING.
 SHEET A-7 SHOWS NEW COLUMNS, THERE IS A BEAM SCHEDULE
 THAT STATES POURED, THESE ARE EXISTING BEAMS? THE SUITE
 528 SHOWS ON THE FRONT OF THE BUILDING EXISTING BUT THE
 WEST FACADE DOES NOT STATE EXISTING ON THE FLOOR PLAN?
 IF THESE ARE TO BE NEW COLUMNS AND BEAMS, THERE SHOULD
 BE A SHORING PLAN SHOWING HOW THE ROOF FRAMIG ROOF DECK
 AND EXISTING PARAPET ARE GOING TO BE HELD IN PLACE
 WHILE THE BEARING WALL IS DEMOLISHED AND REBUILT?
  
 4B) WITH THE WEST ELEVATION WALL BEING REBUILT THE BEAM
 AND COLUMNS ARE SHOWN BUT THERE IS NO MENTION OF THE
 STRAPING OF THE 2X10S AND LOADS TO BE TRANSMITTED INTO
 THE NEW BEAM AND COLUMNS, PART OF THE MWFRS MAIN WIND
 FORCE RESISTING SYSTEM. 1609.1.
  
 4C) SHEET A-6 WALL SECTIONS SHOW STEM WALL
 CONSTRUCTION, SHEET A7 NOTES ON THIS SHEET ARE
 CONFUSSING ON FOUNDATIONS. AT ENTRY AREAS NOTE # 1
 ENTRY PIERS MAY UTILIZE P. T. SOUTHERN PINE NO, 2 GRADE
 2X6 FRAMING W/ CONCRETE SLAB EXTENSION. A 2ND NOTE
 BELOW THIS INDICATES: REMOVE PORTION OF SLAB FOR NEW
 CONCRETE PADS 42X 42X12 INCH W/ #5 6 INCHES EACH WAY.
 ARE ALL NEW COLUMNS GOING TO RECEIVE NEW FOOTER PADS,
 WOULDN'T THE ENTRY FRAMING LAND ON THSE NEW PADS, THE
 HEIGHT OF THE FOUNDATION IS NOT GIVEN? WILL THE STEM
 WALL CONSTRUCTION TAKE PLACE UNTIL THE HEIGHT OF THE
 FINISH FLOOR FOR THE COLUMN AND ENTRY PIERS, ONE POUR
 WITH NO COLD JOINTS?
 2114.2 CONCRETE BEARING LEDGE.
 BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A
 CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL
 THICKNESS OF THE BRICK, STONE OR OTHER VENEER, WHICH IS
 POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO
 SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL
 CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT
 SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE
 IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL
 BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL
 SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED
 IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW
 GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED
 TO THE CAVITY CREATED BETWEEN THE VENEER AND THE
 FOUNDATION, IN LIEU OF A PHYSICAL BARRIER.
  
 4D) TO DATE NO FRAMING DETAILS HAVE BEEN PROVIDED FOR
 THE COVERED ENTRY. 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 FOR BUILDINGS. 107.3.5.1 COMMERCIAL BUILDINGS:
 STRUCTURAL REQUIREMENTS SHALL INCLUDE: WALL/ ROOF
 SYSTEMS
  
 5) 2ND REQUEST. 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 FOR BUILDINGS. THE EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS:FLASHING DETAILS AND WILL THERE
 BE WOOD BUCKS FOR WINDOWS AND DOORS?
 1405.12.7 FLASHING.
 EXPOSED EDGES OF THIN EXTERIOR STRUCTURAL GLASS VENEER
 SHALL BE FLASHED WITH OVERLAPPING CORROSION-RESISTANT
 METAL FLASHING AND CAULKED WITH A WATERPROOF COMPOUND
 IN A MANNER TO EFFECTIVELY PREVENT THE ENTRANCE OF
 MOISTURE BETWEEN THE GLASS VENEER AND THE BACKING.
 1405.13 EXTERIOR WINDOWS AND DOORS.
 WINDOWS AND DOORS INSTALLED IN EXTERIOR WALLS SHALL
 CONFORM TO THE TESTING AND PERFORMANCE REQUIREMENTS OF
 SECTION 1715.5.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-11-18 Cont ID  
Sent By jwitmer Date 2014-11-18 Time 15:07 Rev Time 0.00
Received By jwitmer Date 2014-11-18 Time 11:59 Sent To  
Notes
2014-11-18 15:07:01BUILDING PLAN REVIEW
 PERMIT: 14100651
 ADD: 526 NORTHWOOD
 CONT: K & M CONSTRUCTION
 TEL: (561)383-2817
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 18/ 2014
 ACTION: DENIED
  
 1) THE DESCRIPTION OF WORK ON THE PERMIT APPLICATION
 AND THE SUBMITTED PLANS APPEARS TO BE DIFFERENT SCOP OF
 WORK, IF THE FUTURE ADDITION IS NOT TO BE PART OF THIS
 PERMIT PLEASE STRICKE IT FROM THE PLANS, NOT PART OF
 THIS PERMIT. THE OTHER ISSUE WITH THE PLAN ARE ALL THE
 SHOWN OPENINGS EXISTING OR IS THERE ANY RECONFIGURATION
 OF WINDOWS AND OR DOORS INCLUDING NEW COLUMNS AND
 LINTELS.
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) THE SUBMITTED PLANS DOES NOT INCLUDE THE WIND DESIGN
 CRITERIA FOR THE NEW OPENINGS.
  
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 2.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 2.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 2.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 2.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 2.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) SHEET A-3 VARIOUSELEVATIONS SHOW ORNATE
 ARCHITECTURAL FACADE WORK, THERE ARE NO DETAILS HOW THE
 FACADE WILL BE MADE OR SECURED TO THE BUILDING.
  
 5) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS:FLASHING DETAILS AND WILL THERE BE WOOD
 BUCKS FOR WINDOWS AND DOORS?
 1405.12.7 FLASHING.
 EXPOSED EDGES OF THIN EXTERIOR STRUCTURAL GLASS VENEER
 SHALL BE FLASHED WITH OVERLAPPING CORROSION-RESISTANT
 METAL FLASHING AND CAULKED WITH A WATERPROOF COMPOUND
 IN A MANNER TO EFFECTIVELY PREVENT THE ENTRANCE OF
 MOISTURE BETWEEN THE GLASS VENEER AND THE BACKING.
  
 1405.13 EXTERIOR WINDOWS AND DOORS.
 WINDOWS AND DOORS INSTALLED IN EXTERIOR WALLS SHALL
 CONFORM TO THE TESTING AND PERFORMANCE REQUIREMENTS OF
 SECTION 1715.5.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2014-10-28 Cont ID  
Sent By rlecky Date 2014-10-28 Time 11:39 Rev Time 0.00
Received By rlecky Date 2014-10-28 Time 11:35 Sent To  
Notes
2014-10-28 11:40:08NO ELECTRICAL WORK SHOWN. RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2015-05-14 Cont ID  
Sent By pleduc Date 2015-05-14 Time   Rev Time 0.00
Received By pleduc Date 2015-05-14 Time 13:14 Sent To PC
Notes
2015-05-14 13:16:50PETER LEDUC, FIRE MARSHAL
  
 PLANS RESTAMPED, PREVIOUS COMMENTS REMAIN.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-02-19 Cont ID  
Sent By pleduc Date 2015-02-19 Time   Rev Time 0.00
Received By pleduc Date 2015-02-19 Time 11:37 Sent To  
Notes
2015-02-19 11:51:23PREVIOUS COMMENTS HAVE BEEN REPOSTED TO THIS PROJECT.
  
 THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 CONSIDER THESE AS PROVISO:
  
 DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE
 EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS,
 IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, TOOL,
 OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE
 EGRESS SIDE.
  
 IF THE DOORS WILL BE EQUIPPED WITH A LOCK/LATCH,
 INDICATE HOW THE LOCK/LATCH WILL BE RELEASED FROM THE
 EGRESS SIDE OF THE DOOR.
  
 PER SECTION 7.2.1.5.9, THE LOCK/LATCH RELEASING
 MECHANISM ON ALL DOORS SHALL OPEN THE DOOR WITH NOT
 MORE THAN ONE RELEASING OPERATION. THE RELEASING
 MECHANISM SHALL HAVE AN OBVIOUS METHOD OF OPERATION
 THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS.
 THE RELEASING DEVICE SHOULD BE CAPABLE OF BEING
 OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE TIGHT
 GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO
 OPERATE.
  
 THE MAIN ENTRY IS PERMITTED TO BE EQUIPPED WITH A KEYED
 LOCK WITH LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE
 STATING THE DOOR IS TO REMAIN UNLOCKED DURING BUSINESS
 HOURS. NO OTHER LOCKING OR LATCHING MECHANISMS ARE
 PERMITTED.
  
 THUMB-TURN LOCK IS TO BE EQUIPPED WITH AN ?OPEN/LOCKED?
 INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR).
  
 NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-10-23 Cont ID  
Sent By pleduc Date 2014-10-23 Time   Rev Time 0.00
Received By pleduc Date 2014-10-23 Time 11:40 Sent To  
Notes
2014-10-23 11:55:37THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 CONSIDER THESE AS PROVISOS
  
 DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE
 EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS,
 IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, TOOL,
 OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE
 EGRESS SIDE.
  
 IF THE DOORS WILL BE EQUIPPED WITH A LOCK/LATCH,
 INDICATE HOW THE LOCK/LATCH WILL BE RELEASED FROM THE
 EGRESS SIDE OF THE DOOR.
  
 PER SECTION 7.2.1.5.9, THE LOCK/LATCH RELEASING
 MECHANISM ON ALL DOORS SHALL OPEN THE DOOR WITH NOT
 MORE THAN ONE RELEASING OPERATION. THE RELEASING
 MECHANISM SHALL HAVE AN OBVIOUS METHOD OF OPERATION
 THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS.
 THE RELEASING DEVICE SHOULD BE CAPABLE OF BEING
 OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE TIGHT
 GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO
 OPERATE.
  
 THE MAIN ENTRY IS PERMITTED TO BE EQUIPPED WITH A KEYED
 LOCK WITH LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE
 STATING THE DOOR IS TO REMAIN UNLOCKED DURING BUSINESS
 HOURS. NO OTHER LOCKING OR LATCHING MECHANISMS ARE
 PERMITTED.
  
 THUMB-TURN LOCK IS TO BE EQUIPPED WITH AN ?OPEN/LOCKED?
 INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR).
  
 NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-14 Cont ID  
Sent By pleduc Date 2015-05-14 Time   Rev Time 0.00
Received By pleduc Date   Time   Sent To  
Notes
2015-04-16 17:57:25C17
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-02-27 Cont ID  
Sent By   Date 2015-02-27 Time   Rev Time 0.00
Received By skennedy Date 2015-02-17 Time 17:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2014-12-01 Time   Rev Time 0.00
Received By jgomez Date 2014-10-21 Time 15:33 Sent To  
Notes
2014-10-22 15:33:51SENT TO C13 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2015-02-27 Cont ID  
Sent By jwitmer Date 2015-02-27 Time 14:46 Rev Time 0.00
Received By jwitmer Date 2015-02-27 Time 14:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-11-18 Cont ID  
Sent By jwitmer Date 2014-11-18 Time 15:07 Rev Time 0.00
Received By jwitmer Date 2014-11-18 Time 15:07 Sent To  
Notes
2014-11-18 15:08:20PLANS SHOW A ADDITION NOT SURE IF IT IS TO BE PERMIT
 UNDER THIS PERMIT. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2014-12-01 Cont ID  
Sent By rbergsma Date 2014-12-01 Time   Rev Time 0.33
Received By rbergsma Date 2014-12-01 Time   Sent To  
Notes
2014-12-01 12:57:32NEW LEASING / FUTURE ADDITION NOT IN SCOPE OF
 APPLICATION SHOULD BE REMOVED -- NO MECHANICAL WORK
 SHOWN AT THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status N Date 2015-05-13 Cont ID  
Sent By tklarge Date 2015-05-13 Time 12:27 Rev Time 0.00
Received By tklarge Date 2015-05-13 Time 12:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-11-01 Cont ID  
Sent By tklarge Date 2014-11-01 Time 07:23 Rev Time 0.00
Received By tklarge Date 2014-11-01 Time 07:17 Sent To  
Notes
2014-11-01 07:23:481) THE SCOPE OF WORK SHOWN ON THE PLANS DOES NOT
 CORRELATE WITH THE SCOPE OF WORK SHOWN ON THE
 APPLICATION. WPB AMEND. TO 2010 FBC SEC. 107.2.1.
 2) SUBMIT A SANITARY AND WATER RISER FOR REVIEW. WPB
 AMEND. TO 2010 FBC SEC.107.3.5.1.3.
 3) SUBMIT COMPLETE DETAILS FOR THE HANDICAPPPED
 ACCESSIBLE TOILET ROOMS FOR REVIEW.WPB AMEND. TO 2010
 FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-05-13 Cont ID  
Sent By sgraham Date 2015-05-13 Time 11:13 Rev Time 0.00
Received By sgraham Date 2015-05-13 Time 11:13 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2015-02-24 Cont ID  
Sent By sgraham Date 2015-02-24 Time 09:57 Rev Time 0.00
Received By sgraham Date 2015-02-24 Time 09:57 Sent To  
Notes
2015-02-24 10:01:422/24/15 ZONING FAILED. SG
  
 1. WINDOWS MUST BE RECESSED A MINIMUN OF TWO INCHES
 FROM THE EXTERIOR FACE OF THE FACADE.
 2. AWNING AT THE SIDEWALK LEVEL MUST PROJECT A
 MINIMUNOF FOUR FEET FROM THE BUILDING FACADE AND HAVE A
 MINIMUN OF NINE FEET CLEARANCE FROM THE SIDEWALK LEVEL
 TO THE BOTTOM OF THE AWNING.

Review Stop Z ZONING
Rev No 1 Status F Date 2014-10-27 Cont ID  
Sent By sgraham Date 2014-10-27 Time 15:23 Rev Time 0.00
Received By sgraham Date 2014-10-27 Time 15:23 Sent To  
Notes
2014-10-27 15:23:3210/27/14 ZONING FAILED
  
 1. PLANS MUST REFLECT ONLY THE WORK BEING DONE NOW,
 SPOKE WITH CONTRACTOR, WILL BRING IN NEW PLANS,
 NEW ADDITION TO BUILT IN THE FUTURE