|
 |
 |
 |
 |
 |
Plan Review Details - Permit 14100647
Plan Review Stops For Permit 14100647 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-11-07 |
|
|
Cont ID |
|
Sent By |
JWITMER |
Date |
2014-11-07 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-11-07 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-10-28 |
|
|
Cont ID |
|
Sent By |
SKENNEDY |
Date |
2014-10-28 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2014-10-28 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-10-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-10-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-10-23 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-12-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-12-24 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-12-23 |
Time |
12:42 |
Sent To |
|
|
Notes |
2014-12-23 12:43:55 | TO TKLARGE DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-12-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-12-02 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-21 |
Time |
11:05 |
Sent To |
|
|
Notes |
2014-10-22 11:06:11 | REVISION SENT TO B8 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-12-01 |
|
|
Cont ID |
|
Sent By |
HMOSER |
Date |
2014-12-01 |
Time |
|
Rev Time |
0.50 |
Received By |
rbergsma |
Date |
2014-12-01 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2014-12-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-12-24 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-12-24 |
Time |
08:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-11-01 |
|
|
Cont ID |
|
Sent By |
JWITMER |
Date |
2014-11-01 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-11-01 |
Time |
10:04 |
Sent To |
|
|
Notes |
2014-11-01 10:04:44 | 1) A DRINKING FOUNTAIN IS REQUIRED PER TABLE 403.1 OF | | THE 2010 FL. PLUMBING CODE. THE FL. ACCESSIBILITY CODE | | SEC. 211.2 REQUIRES A MINIMUM OF TWO FOUNTAINS. THE | | DRINKING FOUNTAINS SHALL COMPLY WITH SECS. 211 & 602 OF | | THE 2010 FACBC. | | 2) THE 2" PIPE FOR THE WATER HEATER PAN DRAIN WILL NOT | | HAVE ANYWAY OF RESEALING THE P-TRAP. COMPLY W/ 2010 FBC | | SEC.1002.4. | | 3) THE TWO LAVS IN THE MEN'S RESTROOM REQUIRE VENTS. | | FPC SEC.901.2, 901.2.1. | | 4) CLEANOUTS ARE REQD. IN ALL STACKS PER 2010 FPC | | SEC.708.3.4. | | 5) THE VIEW OF TWO RESTROOM'S DRAINAGE SYSTEM IS | | DIFFICULT TO READ DUE TO THE NAMES OF THE RESTROOMS | | PRINTED OVER THE RISER.SUBMIT A CLEAR, LEGIBLE CODE | | COMPLIANT RISER DOCUMENT. | | 6) AS PRESENTLY DESIGNED THERE ARE TWO MANY OF THE SAME | | TYPE OF FIXTURES ON A WET VENT. COMPLY W/ 2010 FPC | | SEC.909.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |