Plan Review Details - Permit 14100630
Plan Review Stops For Permit 14100630 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-05-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-04 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-04 |
Time |
09:59 |
Sent To |
|
|
Notes |
2015-05-04 14:06:52 | ****PROVISO**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. SEE PROVISO ITEM FROM PERMIT ISSUANCE: | | | | (33). EXITING FROM POOL THROUGH DOOR 138.11 APPEARS TO | | ALSO USE 138.9. GATES ARE TO MEET THE SAME REQUIREMENTS | | AS DOORS, FBC 1008.2. REVISE TO INCLUDE THE GATE | | INFORMATION FOR COMPONENTS SERVING IN THE MEANS OF | | EGRESS AROUND THE POOL AREA. PLAN HAS BEEN REDLINED; | | PLEASE INCORPORATE INTO ARCHITECT'S DRAWINGS. | | | | PLEASE INCORPORATE THIS LANGUAGE INTO ARCHITECT'S PLAN | | AT THIS TIME. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-02-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-02-28 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-28 |
Time |
10:02 |
Sent To |
|
|
Notes |
2015-02-28 13:14:22 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. SEE PROVISO ITEM FROM PERMIT ISSUANCE: | | | | (33). EXITING FROM POOL THROUGH DOOR 138.11 APPEARS TO | | ALSO USE 138.9. GATES ARE TO MEET THE SAME REQUIREMENTS | | AS DOORS, FBC 1008.2. REVISE TO INCLUDE THE GATE | | INFORMATION FOR COMPONENTS SERVING IN THE MEANS OF | | EGRESS AROUND THE POOL AREA. PLAN HAS BEEN REDLINED; | | PLEASE INCORPORATE INTO ARCHITECT'S DRAWINGS. THIS | | SHEET IS NOT REQUIRED TO BE SUBMITTED AT THIS TIME. | | | | 2ND REVIEW, I APOLOGIZE FOR THE AMBIGUOUS LANGUAGE IN | | PREVIOUS REVIEW. PROVISO 33 WAS FROM THE TIME OF PERMIT | | ISSUANCE (AND COPIED AND PASTED INTO REVISION REVIEW). | | PLAN WAS REDLINED AT THAT TIME WITH THE REQUEST THAT | | THE LANGUAGE BE INCORPORATED INTO THE ARCHITECT?S PLAN | | BUT NOT REQUIRED TO BE SUBMITTED AT THAT TIME (MEANING | | THE TIME OF ISSUANCE OF THE PERMIT). | | | | THE LANGUAGE WAS NOT INCORPORATED INTO THE PLAN, AS | | EVIDENCED BY THE REVISION SUBMITTED WITHOUT THE REVISED | | LANGUAGE REGARDING GATES. SO THAT REQUREMENTS ARE CLEAR | | TO ALL PARTIES (CONTRACTOR, SUBS, INSPECTORS), PLEASE | | INCORPORATE THIS LANGUAGE INTO ARCHITECT'S PLAN AT THIS | | TIME. | | | | 3. A0.1.2 AND OTHER SHEETS (LEVELS), EXIT ACCESS IS | | INTERRUPTED BY THE PARKING GARAGE AREA, SEE FBC 1020.1; | | LEVEL OF PROTECTION IS TO BE MAINTAINED UNTIL EXIT | | DISCHARGE. OCCUPANT ENTERS THE RATED CORRIDOR FROM THE | | UNIT, THEN ENTERS THE PARKING GARAGE OR OTHER NON RATED | | STORAGE AREA (SEE MARK ON PLAN), THEN ENTERS THE RATED | | EXIT STAIR. PLEASE REVISE TO PROVIDE CONTINUOUS | | PROTECTION. | | 2ND REVIEW, THIS PORTION OF THE PLAN WAS NOT REVISED. | | SHEET A0.1.2 HAS BEEN MARKED TO NOTE LOCATION OF NON | | CONTINUITY. | | | | 8. A0.1.5, 8TH LEVEL LIFE SAFETY PLAN, SOME ITEMS FROM | | THE ROOF DECK BELOW ARE NOT GREYED OUT. FOR INSTANCE, A | | DOOR IS SHOWN OPENING INTO WHAT APPEARS TO BE A | | CONCRETE EYEBROW TO WHAT APPEARS TO BE OPEN SPACE, ROOF | | DECK BELOW (AT STAIR 3). THIS DOOR IS NOT SHOWN ON | | A2.1.8. PLEASE CORRELATE, GREY OUT ITEMS NOT ACTUALLY A | | PART OF THE 8TH LEVEL, OR PROVIDE AREA/ROOM DESIGNATION | | FOR CLARITY, FBC 107. | | 2ND REVIEW, PURPOSE OF THE DOOR IS NOT CLEAR. IT | | APPEARS TO OPEN ONTO A DROP TO THE LEVEL BELOW. ALSO | | THERE IS ANOTHER AREA WHICH IS NOT CLEAR AS TO WHAT THE | | RECTANGLES DEPICT. THESE TWO AREAS HAVE BEEN MARKED | | (CLOUDED) ON THE PLAN. | | | | NEW COMMENTS: | | | | REV2 1: THIS IS A REMINDER THAT TEST REPORTS FOR | | FLOORING UNDERLAYMENT WILL BE REQUIRED PRIOR TO | | INSTALLATION. PLEASE BE ADVISED THAT, AT THIS TIME, NO | | MANUFACTURER HAS PROVIDED ALL THREE TESTS (FLAME SPREAD | | PER FBC 603.1/803.1.1, IIC PER FBC 1207.3, STC PER FBC | | 1207.2) FOR TILE ON A 6" SLAB WITHOUT A DROPPED | | CEILING. IF YOU DO NOT INTEND TO FIELD TEST FOR SOUND | | (SO A STC/IIC OF 45 IS REQUIRED RATHER THAN 50) YOU ARE | | ENCOURAGED TO ADDRESS THIS ISSUE TIMELY. PLEASE FEEL | | FREE TO CONTACT ME TO DISCUSS WHEN YOU ARE READY TO | | MAKE THE FLOORING UNDERLAYMENT SELECTION. | | | | REV2 2: LOUVERS ARE SHOWN ON SHEET A2.1.2 AND POSSIBLY | | OTHER LOCATIONS, GLASS BLOCK SHOWN ON LEGEND ON A SHEET | | ELEVATIONS (FOR EXAMPLE, A3.1.2). PRODUCT APPROVALS FOR | | ALL COMPONENTS, CLADDING, LOUVERS ARE TO BE SUBMITTED | | (AS A SUBMITTAL, NO FEE) FOR REVIEW PRIOR TO | | INSTALLATION. REVIEW BY DESIGNER OF RECORD REQUIRED | | PRIOR TO SUBMITTAL. IF SUBMITTED IN PAPER FORM, THREE | | SETS REQUIRED. PLEASE NOTE THAT DIGITAL ONLY WILL BE | | REQUIRED AT SOME POINT IN THE NEAR FUTURE. | | | | REV2 3: A2.1.6, A PORTION OF TWO APARTMENTS AND WHAT | | APPEARS TO POSSIBLY BE STAIR #2 ARE SHOWN OUTSIDE OF | | THE BUILDING ENVELOPE (NW CORNER OF BUILDING). THIS HAS | | BEEN MARKED (CLOUDED) ON THE SHEET. PLEASE REMOVE OR | | CLARIFY. | | | | REV2 4: SHEET S0.3 GENERAL NOTE M11 REFERS TO NOA | | 14-0903.02 (CAST CRETE LINTELS). WHEN RESUBMITTING, | | PLEASE UPLOAD THIS NOA FOR THE PERMIT RECORD. | | | | REV2 5: SHEET M2.1.3, CORRIDOR TO STORAGE (SE PORTION | | OF BUILDING), PENETRATIONS THROUGH RATED WALLS REQUIRE | | A FIRE DAMPER, FBC 709.9, 716. 4TH FLOOR ALSO MISSING | | FD IN SAME LOCATION. CHECK ALL AND REVISE ACCORDINGLY. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-12-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-08 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-11-09 |
Time |
12:51 |
Sent To |
|
|
Notes |
2014-12-08 18:33:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. SEE PROVISO ITEMS 17 AND 33 FROM BUILDING PLAN | | REVIEW 3 FOR PERMIT 14030096 AND ADDRESS AT THIS TIME | | OR ADVISE AS TO WHEN THEY WILL BE ADDRESSED. FOR YOUR | | CONVENIENCE, THEY ARE AS FOLLOWS: | | | | (17). S1.8, ROOF DESIGN PRESSURES TREAT ZONE 3 AS ZONE | | 2. PLEASE SEE ASCE7010, FIGURE 30.6-1, FOOTNOTE , | | PARAPET TO BE EQUAL TO OR HIGHER THAN 3FT. DETAIL A | | A7.1 APPEARS TO SHOW A 2FT PARAPET AT STAIR 1, PLEASE | | CLARIFY OR INCLUDE ZONE 3 PRESSURES FOR ROOF CORNER | | ZONES LACKING A 3 FT PARAPET. REVISE ROOF PLAN TO | | CLARIFY WHERE HIGHER ZONE 3 DESIGN PRESSURES ARE | | REQUIRED. PRIOR TO ROOF PERMIT APPLICATION, THIS SHEET | | SHOULD EITHER BE REVISED OR REVISE DETAILS WHICH SHOW A | | 2 FT HIGH PARAPET. THIS IS TO BE SUBMITTED AS A | | REVISION PRIOR TO ROOF PERMIT APPLICATION. | | (33). EXITING FROM POOL THROUGH DOOR 138.11 APPEARS TO | | ALSO USE 138.9. GATES ARE TO MEET THE SAME REQUIREMENTS | | AS DOORS, FBC 1008.2. REVISE TO INCLUDE THE GATE | | INFORMATION FOR COMPONENTS SERVING IN THE MEANS OF | | EGRESS AROUND THE POOL AREA. PLAN HAS BEEN REDLINED; | | PLEASE INCORPORATE INTO ARCHITECT'S DRAWINGS. THIS | | SHEET IS NOT REQUIRED TO BE SUBMITTED AT THIS TIME. | | | | 2. STAIR 6 EXIT DISCHARGE, SHOW PATH TO PUBLIC WAY FBC | | 1027.6. AREA BETWEEN END OF LANDING SHOWN AND SIDEWALK | | IS NOT CLEAR. THE WALKWAY FROM STAIR 6 EXIT DISCHARGE | | TO PUBLIC SIDEWALK IS STILL SHOWN ON SP1 (AND OTHER | | SHEETS SUCH AS CIVILS) BUT THERE IS NO LONGER A DOOR IN | | THIS LOCATION. THE NEW EXIT DOOR LOCATION DOES NOT | | APPEAR TO INCLUDE AN EXIT DISCHARGE WHICH IS CONTINUOUS | | TO THE PUBLIC WAY. | | | | 3. A0.1.2 AND OTHER SHEETS (LEVELS), EXIT ACCESS IS | | INTERRUPTED BY THE PARKING GARAGE AREA, SEE FBC 1020.1; | | LEVEL OF PROTECTION IS TO BE MAINTAINED UNTIL EXIT | | DISCHARGE AFTER THE OCCUPANT ENTERS THE EXIT. IT | | APPEARS THAT THE OCCUPANT ENTERS THE RATED CORRIDOR, | | THEN ENTERS THE PARKING GARAGE OR OTHER NON RATED | | STORAGE AREA, THEN ENTERS THE ENCLOSED STAIR. PLEASE | | REVISE TO PROVIDE CONTINUOUS PROTECTION. | | | | 4. A0.1.2, A2.1.2, THE ACCESS AISLE FOR NORTH END | | ACCESSIBLE PARKING SPACE HAS BEEN REMOVED, FBC 2010 | | ACCESSIBILITY 502.3. CHECK ALL SHEETS. | | | | 5. A0.1.2, THE UNIT TYPES, OTHER ROOM DESIGNATIONS HAVE | | BEEN REMOVED, PLEASE RESTORE (TO EXPEDITE PLAN REVIEW) | | OR EXPLAIN RATIONALE FOR REMOVAL, FBC 107. | | | | 6. A0.1.2, THE FIRE RATED WALL BETWEEN UNITS AT THE | | OPEN PORCH HAVE BEEN REMOVED. SPECIFY WALL TYPE. FOR | | INSTANCE, SHEET A0.1.2, TWO CENTER UNITS AT NORTH | | (PREVIOUSLY MARKED AS TWO A1 UNITS), OTHER LOCATIONS | | ALSO AFFECTED. | | | | 7. A0.1.4, SOUTH WEST DOOR FROM DECK TO CORRIDOR SHOULD | | SWING IN THE DIRECTION OF EGRESS TRAVEL FBC 1008.1.2. | | | | 8.A0.1.5, 8TH LEVEL LIFE SAFETY PLAN, SOME ITEMS FROM | | THE ROOF DECK BELOW ARE NOT GREYED OUT. FOR INSTANCE, A | | DOOR IS SHOWN OPENING INTO WHAT APPEARS TO BE A | | CONCRETE EYEBROW TO WHAT APPEARS TO BE OPEN SPACE, ROOF | | DECK BELOW (AT STAIR 3). THIS DOOR IS NOT SHOWN ON | | A2.1.8. PLEASE CORRELATE, GREY OUT ITEMS NOT ACTUALLY A | | PART OF THE 8TH LEVEL, OR PROVIDE AREA/ROOM DESIGNATION | | FOR CLARITY, FBC 107. | | | | 9. A0.1.5, THE GRAPHICS FOR THE 2 HR RATED MECH SHAFTS | | LOCATED IN THE SOUTH CORRIDOR, STAIR 2, ELEVATOR 1, ALL | | OTHER 2 HOUR RATINGS HAVE BEEN REMOVED; PLEASE RESTORE | | SO DESIGN INTENT IS CLEAR, FBC 708.4, 1022. | | | | 10. A2.1.1, IT APPEARS THAT PARKING SPACES WERE RE | | NUMBERED SO THE DEDICATED LEASING PARKING SPACES NO | | LONGER INCLUDE WHAT IS NOW ACCESSIBLE SPACE NUMBER 13 | | (PREVIOUSLY SPACE NUMBER 11) AND THEREFORE DOES NOT | | COMPLY WITH FBC 2010 ACCESSIBILITY 208.2. PLEASE | | REVISE. COMPLIANCE WITH FAIR HOUSING AND ACCESSIBILITY | | SHOULD BE CLEAR ON THE PLANS. | | | | INDEX PAGE INDICATES THAT SHEET SD 1 INCLUDES PARKING | | DATA. I WAS UNABLE TO LOCATE SUMMARIZED PARKING ON THAT | | SHEET OR ON ANY OTHER SHEET, PLEASE REVISE. | | | | 11. SHEET SP1 HAS A NOTE WHICH PREVIOUSLY STATED *481 | | SPACES* AND NOW STATES *409 SPACES* BUT THIS NUMBER | | DOES NOT APPEAR TO BE CONSISTENT WITH THE TOTAL OF THE | | NUMBER OF PARKING SPACES FOR EACH FLOOR. CLARIFY TOTAL | | UNIT SPACES, TOTAL SPACES DEDICATED TO LEASING AREA, | | TOTAL ACCESSIBLE SPACES (SERVING THE LEASING AREA), | | TOTAL ACCESSIBLE SPACES SERVING UNIT RESIDENTS AND | | THEIR GUESTS. FBC 2010 ACCESSIBILITY/FAIR HOUSING. | | | | 12. SEE FIRE COMMENTS REGARDING DAMPERS AND EXIT | | LIGHTING. THIS IS ALSO REQUIRED BY FBC 713 AND FBC | | 1011.1. | | | | 13. S0.4, STRUCTURAL STEEL NOTE APPEARS INCOMPLETE, SEE | | SS12. | | | | 14. SHEET S 1.4 HAS NOT BEEN CORRECTLY NAMED; THIS | | SHOULD BE S1.4.4. SHEET S 1.4 HAS BEEN REMOVED FROM | | THIS PROJECT (SEE INDEX SHEET) AND THE NEW SHEET S1.4.4 | | SHOULD BE NAMED PROPERLY IN ORDER TO REPLACE THE | | PREVIOUS VERSION. | | | | 15. DUE TO FILE NAMING, SOME SHEETS ARE NOT IN ORDER. | | FOR INSTANCE, S1.3B APPEARS BEFORE S1.3A; SHEETS S1.4.4 | | A THROUGH C DO NOT FOLLOW S1.4.4 (SO, THE STRUCTURAL | | DRAWINGS FOR THE 4TH FLOOR FOLLOW THE 6TH FLOOR). | | PLEASE COORDINATE WITH OUR PROJECTDOX COORDINATOR TO | | DETERMINE THE IMPACT ON RECORDS RETENTION AND ISSUANCE | | OF THE REVISION (IF ANY) OTHER THAN THE FACT THAT, IN | | THE FIELD (FOR COORDINATION, CONSTRUCTION, AND | | INSPECTIONS), PAGES WILL NOT BE IN THE ORDER ON THE | | INDEX SHEET, AND STRUCTURAL INFORMATION BY FLOOR MAY | | ALSO BE OUT OF ORDER. IT IS STRONGLY SUGGESTED THAT, | | SINCE THE PLANS INCLUDE OVER 200 SHEETS, FILES BE | | RENAMED SO THAT ALL SHEETS PRINT IN THE ORDER OF THE | | INDEX PAGE, FBC 107. | | | | 16. SHEET S1.4.4B NOTE IN THE BOX NEAR THE BOTTOM RIGHT | | CORNER REFERS TO SHEET S1.4A WHICH, ACCORDING TO THE | | INDEX, NO LONGER EXISTS. PLEASE REVISE THIS AND ANY | | OTHER NOTES WHICH REFER TO THE SHEETS (S1.4, 1.4A, | | 1.4B, 1.4C) WHICH HAVE BEEN ELIMINATED. OR, RESTORE | | SHEETS AND REVISE INDEX TO REFLECT, FBC 107. | | | | 17. GARAGE FRAMING NOTES APPEAR INCOMPLETE. SEE SHEET | | S1.5A, *GARAGE FRAMING NOTES*, NOTES 4, 6 AND REVISE TO | | REFER TO CORRECT SHEETS. PLEASE CHECK ALL SIMILAR NOTES | | ON ALL SHEETS AS THIS APPEARS TO OCCUR ON OTHER SHEETS. | | | | 18. SEE ITEM 1 REGARDING PROVISO ITEM CONCERNING | | PREVIOUS COMMENT LIST NUMBER 17. DETAIL 1 S1.7B DOES | | NOT APPEAR TO SHOW A PARAPET AT THE ELEVATOR ROOF, AND | | SHEET S1.7A (AND OTHER SHEETS, DETAILS) PARAPET LEGEND | | SHOWS A 2FT PARAPET AT STAIRS. THIS COMMENT WAS IN | | BUILDING PLAN REVIEWS 1 AND 2 AND PERMIT WAS ISSUED | | WITH PROVISO THAT THIS BE REVISED. IF ENGINEER | | DISAGREES WITH THIS COMMENT, PLEASE CONTACT ME. IF | | ENGINEER DOES NOT DISAGREE WITH THIS COMMENT, PLEASE | | EITHER REVISE ROOF PRESSURES ON SHEET S1.8 OR ADVISE AS | | TO WHEN THIS SHEET WILL BE REVISED. | | | | PERMIT WAS ISSUED WITH PROVISO THAT THIS SHEET BE | | REVISED (OR THIS ISSUE OTHERWISE RESOLVED) PRIOR TO | | ISSUANCE OF THE ROOFING PERMIT. A ROOF SUB PERMIT WAS | | APPLIED FOR ON NOV 25. A PRINT HOLD HAS BEEN PLACED ON | | THIS PERMIT SUBJECT TO RESOLUTION OF THIS COMMENT. | | | | 19. S5.1, TYPICAL CONCRETE COLUMN, INCLUDES REFERENCE | | TO PILE CAP. PLEASE REMOVE, FBC 107, OR INDICATE WHERE | | PILES WILL BE INSTALLED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-06-10 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-10 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-10 |
Time |
14:18 |
Sent To |
|
|
Notes |
2015-06-10 16:42:18 | 6/10/2015 | | PROJECT: LOFTIN PLACE | | PERMIT#: 14030096 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW OF REVISION# 14100630 | | ACTION: APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN | | APPROVED PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | 1) SHEET E-1.1.1 | | RELOCATE NOTE THAT WAS ADDED REGARDING THE SITE AND | | LANDSCAPE LIGHTING IN THE VICINITY OF THE POOL. THE | | NOTE WAS INADVERTENTLY PLACED ON TOP OF THE PLAN AND IS | | DIFFICULT TO SPOT AND READ. RELOCATE THE NOTE FOR | | CLARIFICATION TO AN OPEN SPACE ON THE SHEET WHERE IT | | WILL BE EASIER TO SPOT AND READ. WPB AMENDMENTS TO FBC | | 107. | | | | 2) E-4.1 | | A) THE JUNCTION BOX FOR A ?FUTURE? RADON DETECTOR IS | | LOCATED DIRECTLY ABOVE THE BATH TUB. VERIFY THE | | LOCATION TO AVOID FUTURE ACCESS, AND INSTALLATION, AND | | ISSUES OVER THE TUB WITH THE PROPOSED RADON DETECTORS. | | B) CLARIFY THE FIXTURES IN THE CLOTHES CLOSETS MUST | | COMPLY WITH THE NEC 410.16 FOR LUMINAIRES IN A CLOTHES | | CLOSET. | | C) ILLUMINATION IS REQUIRED FOR THE ELECTRICAL AND LOW | | VOLTAGE PANELS. NEC 110.26(D) | | D) ALL HABITABLE ROOMS REQUIRE A SWITCH LIGHTING | | OUTLET. NEC 210.70 | | THE BEDROOMS INDICATE A SWITCH CONTROLLED CEILING FAN | | BUT NO SWITCH CONTROLLED LIGHT OUTLET. | | | | 3) E-4.2 | | A) THE JUNCTION BOX FOR A ?FUTURE? RADON DETECTOR IS | | LOCATED DIRECTLY ABOVE THE BATH TUB. VERIFY THE | | LOCATION TO AVOID FUTURE ACCESS, AND INSTALLATION, AND | | ISSUES OVER THE TUB WITH THE PROPOSED RADON DETECTORS. | | B) CLARIFY THE FIXTURES IN THE CLOTHES CLOSETS MUST | | COMPLY WITH THE NEC 410.16 FOR LUMINAIRES IN A CLOTHES | | CLOSET. | | C) ILLUMINATION IS REQUIRED FOR THE ELECTRICAL AND LOW | | VOLTAGE PANELS. NEC 110.26(D) | | D) ALL HABITABLE ROOMS REQUIRE A SWITCH LIGHTING | | OUTLET. NEC 210.70 | | THE BEDROOMS INDICATE A SWITCH CONTROLLED CEILING FAN | | BUT NO SWITCH CONTROLLED LIGHT OUTLET. | | | | 4) E-6.1.1 | | SWITCHBOARD ?4?, CIRCUIT 3 FEEDS PANEL L FROM A 350AMP | | OCPD AND INDICATES TO REFERENCE THE PANEL SCHEDULE FOR | | PANEL ?L? FOR THE FEEDER SIZE. PANEL L DOES NOT | | INDICATE THE FEEDER SIZE, NEITHER DOES THE RISER | | DIAGRAM. THE RISER DIAGRAM INDICATES TO REFERENCE NOTE | | 17 FOR THE FEEDER SIZE. BUT NOTE 17 SAYS TO REFERENCE | | THE PANEL SCHEDULE. PROVIDE THE FEEDER SIZE FOR THE | | FEEDER FROM SWITCHBOARD ?4? TO PANEL L | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | ARE REQUIRED FOR SWIMMING POOL, SITE LIGHTING, | | GENERATORS, FIRE ALARM, ACCESS CONTROL SYSTEM, | | SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, | | COMMUNICATION. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-03-05 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-03-05 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-03-02 |
Time |
08:51 |
Sent To |
|
|
Notes |
2015-03-05 13:07:21 | 3/3/2015 | | PROJECT: LOFTIN PLACE REVISION | | PERMIT#: REVISION TRACKING# 14030096 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 2ND ELECTRICAL PLAN REVIEW OF REVISION 14100630 | | ACTION: DENIED | | | | SHEET E-1.1.0 | | ADD NOTES TO ADDRESS THE AUTOMATIC CONTROL OF INTERIOR | | AND EXTERIOR LIGHTING AS REQUIRED THROUGHOUT. FBC | | 505.2.2 | | THIS NOTE SHOULD ALSO BE ADDED TO THE PANEL SCHEDULES | | CONTROLLING LIGHTING IN THESE COMMON AREAS | | | | SHEET E-1.1.1 | | 1) MOVE THE NEW NOTE THAT WAS INCLUDED TO ADDRESS THE | | PREVIOUS REVIEW COMMENT REGARDING LIGHTING IN THE | | VICINITY OF A SWIMMING POOL. NEC ARTICLE 680.8-10. THIS | | NOTE WAS PLACED ON TOP OF THE PLAN RATHER THAN BEING | | PLACED IN AN OPEN SPACE FOR CLARITY. | | | | SHEET E-2.1.1 | | 2) MOVE THE NOTE ?ALL CORRIDOR RECEPTACLES SHALL BE | | GFCI AND TAMPER RESISTANT? THIS NOTE WAS PLACED ON TOP | | OF THE PLAN RATHER THAN BEING PLACED IN AN OPEN SPACE | | FOR CLARITY. THE SYMBOL SHOULD BE CHANGED IN ALL | | CORRIDORS TO INDICATE THIS PARTICULAR OUTLET TYPE ON | | THE FLOOR PLAN. | | | | SHEET E-4.1 AND E-4.2 | | 3) ALL HABITABLE ROOMS REQUIRE A SWITCH LIGHTING | | OUTLET. NEC 210.70 | | THE BEDROOMS INDICATE A SWITCH CONTROLLED CEILING FAN | | BUT NO SWITCH CONTROLLED LIGHT OUTLET. THE GREAT ROOM | | INDICATES A SWITCH CONTROLLED RECEPTACLE BUT THE SYMBOL | | FOR THE OUTLET IS NOT DESIGNATED AS A SWITCH CONTROLLED | | RECEPTACLE. | | | | 4) THE OUTLETS REQUIRED BY 210.52 (SPACING) DO NOT | | INCLUDE THE OUTLETS INDICATED FOR WALL MOUNTED TV?S | | WHERE THE RECEPTACLE OUTLET WILL BE INSTALLED ABOVE OR | | WHERE THEY ARE CONTROLLED BY A SWITCH SUCH AS IN THE | | GREAT ROOM. 210.52 ADDITIONAL RECEPTACLE OUTLET ARE | | REQUIRED TO MEET THIS CRITERIA. | | | | 5) ADDITIONAL OUTLETS ARE REQUIRED AT THE KITCHEN | | COUNTERTOP BETWEEN THE STOVE AND THE SINK. 210.52 | | | | 6) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | PLANS AND ENGINEERING ARE REQUIRED FOR SITE LIGHTING, | | GENERATORS. HOOD EXHAUST, FIRE ALARM, ACCESS CONTROL | | SYSTEM, SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, | | AND, COMMUNICATION. | | | | SHEET E-4.3 | | 7) ADDITIONAL EMERGENCY LIGHTING IS REQUIRED FOR THE | | COMMON AREA CORRIDORS, STAIRS, AND LOBBY AREAS. NEC | | 700.16, 700.12 | | | | SHEET E-6.11 | | 8) PARKING LOT LIGHTS ARE ALSO REQUIRED TO BE | | CONTROLLED SO AS NOT TO BE IN OPERATION WHEN NOT | | REQUIRED OR DURING DAYTIME HOURS. THE REQUIREMENTS OF | | FBC-ENERGY SECTION 505.2 WILL ALSO APPLY TO THESE | | CIRCUITS. | | | | SHEET E-6.1.2 | | 9) A SIMPLE TIME CLOCK IS NOT SUFFICIENT FOR CONTROL OF | | THE EXTERIOR LIGHTING TO COMPLY WITH THE FBC-ENERGY | | SECTION 505.2. STATES: ?LIGHTING FOR ALL EXTERIOR | | APPLICATIONS NOT EXEMPTED IN SECTION 505.1 SHALL HAVE | | AUTOMATIC CONTROLS CAPABLE OF TURNING OFF EXTERIOR | | LIGHTING WHEN SUFFICIENT DAYLIGHT IS AVAILABLE OR WHEN | | THE LIGHTING IS NOT REQUIRED DURING NIGHTTIME HOURS. | | LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY EITHER A COMBINATION OF A | | PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME | | SWITCH.? | | | | SHEET E-9.1.1 | | 10) REVISE THE LIGHTING FIXTURE SCHEDULE TO INCLUDE THE | | FIXTURES STAIRWAY LIGHTING THAT ARE REQUIRED TO HAVE | | BATTERY BACKUP. NONE OF THE SYMBOLS IN THE LEGEND | | INCLUDE THE FIXTURE SYMBOL THAT HAS BEEN ADDED IN THE | | STAIRWAYS THAT REQUIRE BATTERY BACKUP. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-12-12 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-12-12 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-12-12 |
Time |
09:20 |
Sent To |
|
|
Notes |
2014-12-12 09:33:05 | 12/11/2014 | | PROJECT: LOFTIN PLACE REVISION | | PERMIT#: 14030096 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW OF REVISION 14100630 | | ACTION: DENIED | | | | SHEET E-1.1.1 | | 1) VERIFY THE LOCATION, AND ELEVATION OF POWER AND | | LIGHTING INCLUDING THEIR ASSOCIATED CONDUITS AND WIRING | | IN THE VICINITY OF THE SWIMMING POOL. NEC680.8.680.10, | | 680.22, 680.24 | | | | SHEET E-2.1.2 | | 1) EMERGENCY LIGHTING SHALL BE FED BY LIGHTING CIRCUIT | | OF SAME LOCAL AREA. NEC 700.12 (F) (4) | | | | E.2.1.7 | | 2) LIGHTING FOR ALL EXTERIOR APPLICATIONS NOT EXEMPTED | | IN SECTION 505.1 SHALL HAVE AUTOMATIC CONTROLS CAPABLE | | OF TURNING OFF EXTERIOR LIGHTING WHEN SUFFICIENT | | DAYLIGHT IS AVAILABLE OR WHEN THE LIGHTING IS NOT | | REQUIRED DURING NIGHTTIME HOURS. LIGHTING NOT | | DESIGNATED FOR DUSK-TO-DAWN OPERATION SHALL BE | | CONTROLLED BY EITHER A COMBINATION OF A PHOTOSENSOR AND | | A TIME SWITCH, OR AN ASTRONOMICAL TIME SWITCH. FBC | | 505.2.4 EXTERIOR LIGHTING CONTROLS. | | | | 3) PROVIDE WIND LOAD CALCULATIONS FOR ALL LIGHT POLES | | INCLUDING LUMINAIRE IN COMPLIANCE WITH THE FBC 1609 | | | | SHEET E-4.1 | | 4) STUDIO ONE UNIT REQUIRES AN OUTLET AT THE KITCHEN | | ISLAND. NEC 210.52 | | | | SHEET 4.1A | | 5) PANEL A1 INDICATES CIRCUIT #1,3 FOR THE A/C IS A | | 2POLE 35 WITH #12. REVISE THE PANEL SCHEDULE TO | | INDICATE A CIRCUIT CONDUCTOR ADAQUATE FOR THE 35AMP | | OCPD. NEC 310.16 | | | | E-4.3 | | 6) THE CORRIDORS AND COMMON AREAS REQUIRE EMERGENCY | | LIGHTING. LIGHTING SYSTEMS SHALL BE DESIGNED AND | | INSTALLED SO THAT THE FAILURE OF ANY INDIVIDUAL | | LIGHTING ELEMENT, SUCH AS THE BURNING OUT OF A LAMP, | | CANNOT LEAVE IN TOTAL DARKNESS ANY SPACE THAT REQUIRES | | EMERGENCY ILLUMINATION. NEC 700.16 | | | | 7) IDENTIFY ALL LIGHTING CIRCUITS ON THE FLOOR PLAN. | | FBC 107.3.2 | | | | 8) EMERGENCY LIGHTING SHALL BE FED BY LIGHTING CIRCUIT | | OF SAME LOCAL AREA. NEC 700.12 (F) (4) | | | | E-4.4 | | 9) PROVIDE EMERGENCY LIGHTING FOR STAIRWELLS. EMERGENCY | | LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED SO | | THAT THE FAILURE OF ANY INDIVIDUAL LIGHTING ELEMENT, | | SUCH AS THE BURNING OUT OF A LAMP, CANNOT LEAVE IN | | TOTAL DARKNESS ANY SPACE THAT REQUIRES EMERGENCY | | ILLUMINATION. NEC 700.16 | | | | E-5.1.1 | | 10) CLARIFY THE CIRCUIT FEEDING THE FIRE PUMP. THE | | RISER ON 7.1.1 INDICATES THE FIRE PUMP SERVICE FROM THE | | UTILITY TO THE FIRE PUMP CONTROLLER AND THE FLOOR PLAN | | ON SHEET 5.1.1 INDICATES THE FIRE PUMP BEING FED FROM | | SWITCHBOARD 4 CIRCUIT #10 AND THE PANEL SCHEDULE FOR | | SWITCH BOARD 4 CIRCUIT #10 INDICATES A SPACE. REVISE | | THE FLOOR PLAN ON SHEET 5.1.1 TO INDICATE THE ACTUAL | | FEEDER. | | | | E-6.1.1 | | 11) REVISE PANEL SCHEDULES AND LOAD CALCULATIONS IN | | SWITCH BOARD 2 AND 3. THE TOTAL CALCULATED LOADS | | REPRESENTED IN THE CHART LABELED TOTAL UNIT CONNECTED | | LOAD STATES THE TOTAL CONNECTED LOAD IN VA PER METER | | CENTER. THE PANEL SCHEDULE FOR SWITCH BOARD ?3? | | INDICATES THE LOADS TO BE SLIGHTLY DIFFERENT THAN WHAT | | IS REPRESENTED IN THE CHART ON E7.1.1 PARTICULARLY THE | | LOAD FOR METER CENTER 8. THE PANEL SCHEDULE ON E6.1.1 | | INDICATES MC 8 WITH A TCL OF 847.7KVA BUT THE LOAD | | INDICATED IN THE CHART ON E7.1.1 IS INDICATED TO BE | | 1,078,144VA OR 1,078KVA. REVISE LOADS IN PANEL | | SCHEDULES AND LOAD CALCULATIONS TO BE ACCURATE AND TO | | MATCH FROM PAGE TO PAGE | | | | E-7.1.1. AND E-7.1.2 | | 12) NEC240.4(C) WHERE THE OVERCURRENT DEVICE IS RATED | | OVER 800 AMPERES, THE AMPACITY OF THE CONDUCTORS IT | | PROTECTS SHALL BE EQUAL TO OR GREATER THAN THE RATING | | OF THE OVERCURRENT DEVICE DEFINED IN NEC 240.6. 3 SETS | | OF 500MCM CU IS NOT ADEQUATE FOR A 1200AMP OCPD | | 13) VERIFY SAME FOR ALL SERVICE ENTRANCE AND FEEDERS | | | | 14) NEC240.4(C) DEVICES RATED OVER 800 AMPERES. WHERE | | THE OVERCURRENT DEVICE IS RATED OVER 800 AMPERES, THE | | AMPACITY OF THE CONDUCTORS IT PROTECTS SHALL BE EQUAL | | TO OR GREATER THAN THE RATING OF THE OVERCURRENT DEVICE | | DEFINED IN NEC 240.6 | | 3 SETS OF 500MCM CU IS NOT ADEQUATE FOR A 1200AMP OCPD | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2014-12-16 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2014-12-16 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2014-12-16 |
Time |
|
Sent To |
I |
|
Notes |
2014-12-16 11:58:05 | SHEET C7 REVISIONS ARE ACCEPTABLE. | | | | FDC LOCATION IS ADEQUATE AS REQUESTED PER FIRE REVIEW. | | | | EOR WILL PROVIDE AS-BUILT LOCATION OF SUCH ELEMENT TO | | CITY OF WPB PUBLIC WORKS DEPARTMENT UPON REQUESTING | | TCO/CO. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2015-04-29 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-04-29 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-04-29 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2015-02-26 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-02-26 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-02-24 |
Time |
16:23 |
Sent To |
|
|
Notes |
2015-02-24 16:23:59 | 705 NORTH OLIVE AVEUE | | TRACKING #14100630 | | PERMIT #14030096 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | REPEAT COMMENT - SHEET A-0.1.2: THE FIRE RATED NORTH | | CORRIDOR NO LONGER PROVIDES DIRECT ACCESS INTO THE EXIT | | STAIR ENCLOSURE (STAIR #5) PER FFPC SECTION 7.5.1.1.1. | | THE FIRE RATING SEPARATING THE PARKING GARAGE (STORAGE) | | FROM RESIDENTIAL HAS BEEN RELOCATED REQUIRING APARTMENT | | OCCUPANTS TO ENTER THE STORAGE OCCUPANCY TO REACH THE | | PROTECTED EXIT. PER FFPC SECTION 7.5.1.6 EXIT ACCESS | | SHALL BE ARRANGED SO THAT IT IS NOT NECESSARY TO PASS | | THROUGH ANY AREA IDENTIFIED UNDER PROTECTION OF HAZARDS | | (STORAGE: SEETABLE 30.3.2.1.1). TYPICAL ALL LEVELS. | | | | | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2014-11-19 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-11-19 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-11-18 |
Time |
11:12 |
Sent To |
|
|
Notes |
2014-11-18 17:13:28 | 705 NORTH OLIVE AVEUE | | TRACKING #14100630 | | PERMIT #14030096 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET A-0.1.2: THE FIRE RATED NORTH CORRIDOR NO LONGER | | PROVIDES DIRECT ACCESS INTO THE EXIT STAIR ENCLOSURE | | (STAIR #5) PER FFPC SECTION 7.5.1.1.1. THE FIRE RATING | | SEPARATING THE PARKING GARAGE (STORAGE) FROM | | RESIDENTIAL HAS BEEN RELOCATED REQUIRING APARTMENT | | OCCUPANTS TO ENTER THE STORAGE OCCUPANCY TO REACH THE | | PROTECTED EXIT. PER FFPC SECTION 7.5.1.6 EXIT ACCESS | | SHALL BE ARRANGED SO THAT IT IS NOT NECESSARY TO PASS | | THROUGH ANY AREA IDENTIFIED UNDER PROTECTION OF HAZARDS | | (STORAGE: SEETABLE 30.3.2.1.1). TYPICAL ALL LEVELS. | | | | SHEET A-0.1.4: THE WEST EXIT ACCESS DOOR LEADING FROM | | THE ASSEMBLY ROOF AREA INTO THE EXIT ACCESS CORRIDOR | | HAS A DOOR SWING THAT IS AGAINST THE FLOW OF TRAFFIC. | | | | SHEET M-4.4: SEVERAL SECTIONS OF DUCTWORK ARE | | PENETRATING FIRE RATED WALLS WITH NO DAMPERS SHOWN. | | REFER TO SHEET A--0.1.2 FOR FIRE RATED WALL LOCATIONS. | | | | SHEET E-4.3: SEVERLY DEFICIENT EXIT SIGNAGE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-06-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-06-11 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-03-27 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-03-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-03-05 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-01-29 |
Time |
11:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-12-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-12-27 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-01-29 |
Time |
11:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-03-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-03-02 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-03-02 |
Time |
09:22 |
Sent To |
|
|
Notes |
2015-03-02 11:23:49 | PASS | | 1) REFER TO SECTION 607.5.5 SHAFT ENCLOSURE MOTORIZED | | DAMPERS REQUIRED | | 2010 FBC (M) | | 2) RTU TIE DOWN DETAIL IS NOT RECOMMENDED BECAUSE OF | | MAINTENANCE ISSUES | | 3) REFER TO SECTION 602.2.1 INCLUDING A/C CLOSET DOORS | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-12-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-12-27 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-11-05 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-12-27 07:47:53 | PASS PROVISO | | REFER TO SECTION 602.2.1 MATERIALS WITHIN PLENUM'S | | INCLUDING DOORS 2010 FBC (M) | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-02-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-02-07 |
Time |
06:38 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-02-07 |
Time |
04:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-11-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-11-07 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-11-07 |
Time |
04:59 |
Sent To |
|
|
Notes |
2014-11-07 07:36:08 | | | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 1) DWG. P-5.1 - THE WATER RISER FOR UNIT # B1 APPEARS | | TO HAVE THE PIPE SIZES REVERSED AND THE HOT AND COLD | | WATER LINES ARE REVERSED AT SOME OF THE FIXTURES. MOST | | OF THE FIXTURES ARE BEING FED FROM A 1/2 " COLD WATER | | LINE. | | 2) DWG. P-5.4C - RISER #117 - THE VENT STACK IS SHOWN | | AS 3" AND ON SHT. P-5.3 IT IS SHOWN AS 4". CLARIFY. | | 3) SHT.P-5.4C - RISER #113 IS LABELED AS RISER #13 - | | CORRECT | | 4) DWG.P-5.2 - PLEASE EXPLAIN HOW YOU ARRIVED AT THE | | FIXTURE UNIT LOAD FOR THE WATER PIPING. | | 5) WG. P-5.5 - STORM COLLECTION RISER #1 - A 3" ROOF | | DRAIN WITH A COLLECTION AREA OF 1520 SQ. FT.IS | | DISCHARGING INTO A HORIZONTAL LINE THAT IS 4 " IN | | DIAMETER. THE MAXIMUM SQUARE FOOTAGE PERMITTED ON A 4" | | LINE AT MIN. 1/8" SLOPE IS 1504 SQ. FT. THIS LINE HAS | | TO BE INCREASED TO 5 " OR THE SLOPE OF THE PIPE SHALL | | BE INCREASED TO 1/4 " SLOPE PER FT. | | 6) PROVIDE A LEGEND FOR THE HOT AND COLD WATER LINES ( | | THE WATER RISERS SHOW THE LINES IDENTIFIED WITH ONE AND | | TWO DASHES. JUST IDENTIFY WHICH ONE IS FOR HOT AND | | WHICH ONE IS FOR COLD). | | 7) SHT. P-5.3 - THE BOTTOM HALF OF THE PAGE - THE | | GROUPS OF RISER NUMBERS ARE SPACED SO CLOSE TO EACH | | OTHER THAT IT IS DIFFICULT TO FIGURE OUT WHICH RISER | | NUMBERS APPLY TO THE SPECIFIC RISERS. | | 8) DWG. P-5.3 - SHOWS RISER # 117 FOR TWO DIFFERENT | | RISERS - CLARIFY. | | 9) DWG.P-6.2 - A WATER HAMMER ARRESTOR SHALL BE | | INSTALLED ON THE TRASH CHUTE WASHDOWN PER 2010 FPC | | SEC.604.9. | | 10) DWG. P-6.2 - THE EJECTOR SHALL BE PROVIDED WITH A | | FULL FLOW VALVE ( SHUTOFF VALVE) AND CHECK VALVE | | LOCATED IN THE DISCHARGE PIPING BETWEEN THE PUMP OR | | EJECTOR AND THE GRAVITY DRAINAGE SYSTEM. 2010 FPC | | SEC.712.2. | | 11) IF THE ELEVATOR IS A HYDRAULIC ELEVATOR THE | | EFFLUENT FROM THE SUMP PIT SHALL DISCHARGE INTO AN OIL | | SEPARATOR. INDICATE ON THE DRAWING IF THE ELEVATOR IS | | CBLE DRIVEN OR HYDRAULIC. | | 12) DWG. P-6.2 - INDICATE ON THE PLAN WHETHER THE FLOOR | | DRAIN RECEIVING THE WASTE FROM THE ELEVATOR PIT IS | | DISCHARGING TO THE STORM OR SANITARY. | | 13) DWG. P-5.4B - INDICATE THE SLOPE OF THE 8" SANITARY | | LINE ON THE DRAWING. COMPLY W/2010 FPC TABLE 710.1 (1) | | FOR THE SLOPE OF PIPE AND THE MAXIMUM NUMBER OF FIXTURE | | UNITS THAT THE PIPE CAN CARRY. | | 14) ANY WASHING MACHINE BOXES LOCATED IN FIRE RATED | | WALLS SHALL EITHER BE FIRE RATED OR INSTALLED TO | | MAINTAIN THE FIRE RATING OF THE WALL. 2010 FBC SEC.713. | | 15) DWG. P-6.2 - THE P & T LINES AND PAN DRAINS SHALL | | NOT USE THE SAME RISER PER THE 2010 FPC SEC.504.6 (4). | | 16) DWG.P-6.2 - THE PAN DRAIN SHALL BE DRAINED BY AN | | INDIRECT WASTE PIPE PER THE 2010 FPC SEC. 504.7.1. | | 17) DWG. P-5.6A - SHOWS THE RELIEF LINES AS A DIRECT | | CONNECTION TO THE RISER AND THE WATER HEATER DETAIL ON | | DWG. P-6.2 SHOWS RELIEF LINES DISCHARGING TO AN AIR GAP | | FITTING . CLARIFY. | | 18) COMBUSTIBLE MATERIALS ARE NOT PERMITTED IN RETURN | | AIR PLENUMS PER THE 2010 FPC SEC.307.6 FL. MECH CODE. | | SEC.602.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2015-06-26 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-26 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-23 |
Time |
12:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-12-18 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-12-18 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-12-18 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-12-18 14:30:49 | PROVISO: THE FOLLOWING ITEMS SHALL BE CORRECTED: | | 1. BALCONIES AND EYEBROWS REMOVED OR REDUCED IN SIZE | | SHALL BE RESTORED TO THE ORIGINAL DIMENSION APPROVED AS | | PART OF THE DAC SPECIAL REVIEW. THE REMOVAL OF THE | | BALCONIES ALTERS THE FACADE APPROVED BY THE BOARD IN A | | SUBSTANTIAL MANNER. | | 2. AWNINGS ORIGINALLY INDICATED AND APPROVED AS PART OF | | THE DAC SPECIAL REVIEW SHALL BE MAINTAINED. A SEPARATE | | PERMIT FOR AWNINGS SHALL BE SUBMITTED. | | 3. CONFIRM PARKING AREAS ARE NOT EXPOSED TO THE SKY. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
|