Plan Review Details - Permit 14100611
Plan Review Stops For Permit 14100611 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-12-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-01 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-12-01 |
Time |
13:16 |
Sent To |
|
|
Notes |
2014-12-01 13:17:52 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | DESIGNER DID NOT PROVIDE ROOM DESIGNATION AS PER | | COMMENT LIST. SEE FBC R310.4: | | | | THE MEANS OF ESCAPE SHALL BE WITHIN THE FIRST FLOOR OF | | THE DWELLING OR DWELLING UNIT AND SHALL NOT BE LOCATED | | WITHIN A GARAGE WITHOUT A SIDE-HINGED DOOR LEADING | | DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART OF THE | | DWELLING OR DWELLING UNIT SHALL BE ABLE TO ACCESS THE | | MEANS OF ESCAPE WITHOUT PASSING THROUGH A LOCKABLE DOOR | | NOT UNDER THEIR CONTROL. | | | | PERMIT IS ISSUED WITH PROVISO - MEANS OF ESCAPE SHOWN | | ON PLAN SHALL MEET THE REQUIREMENTS OF FBC R 310.4. | | | | IF MEANS OF ESCAPE DOES NOT COMPLY WITH THIS | | REQUIREMENT, REVISE PLAN AND RESUBMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-10-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-22 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-22 |
Time |
13:19 |
Sent To |
|
|
Notes |
2014-10-22 13:20:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | INCLUDE THE ROOM DESIGNATION. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-12-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-01 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-11-19 |
Time |
16:34 |
Sent To |
|
|
Notes |
2014-11-20 16:34:48 | RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-22 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-22 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |