Plan Review Details - Permit 14100434
Plan Review Stops For Permit 14100434 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-11-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-11-08 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-11-08 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-10-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-28 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-28 |
Time |
12:04 |
Sent To |
|
|
Notes |
2014-10-28 12:08:07 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. PROVIDE A STRUCTURAL DETAIL FOR THE PROPOSED SIGN, | | FBC 1609. WIND DESIGN CRITERIA AND ALL INFORMATION | | REGARDING SIGN CONSTRUCTION AND FASTENING TO BE | | INCLUDED. | | | | 2. THE DRAWING SUBMITTED HAS THE SIGN DRAWING GREYED | | OUT. IT IS DIFFICULT TO READ. SEE FBC 107, PLANS TO BE | | ARCHITECTURAL QUALITY. THE PLANS MUST BE LEGIBLE ENOUGH | | TO EASILY READ DURING PLAN REVIEW, IN THE FIELD | | (INSPECTIONS), AND FOR RECORD RETENTION. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-11-05 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-11-05 |
Time |
09:51 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-10-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-10-24 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-24 |
Time |
13:32 |
Sent To |
|
|
Notes |
2014-10-24 13:56:35 | 10/24/2014 | | PROJECT: VINCE CAMUTO SIGN | | PERMIT#: 14100434 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) INDICATE THE LISTING OF THE SIGN. NEC 600.3 | | | | 2) PROVIDE A EXTERNALLY OPERABLE DISCONNECT SWITCH | | WITHIN SIGHT OF THE SIGN. NEC 600.6(A)(1) | | | | 3) INDICATE COMPLIANCE WITH THE FBC-ENERGY 505.2.4 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-11-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-11-08 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-11-03 |
Time |
16:50 |
Sent To |
|
|
Notes |
2014-11-03 16:51:23 | SENT TO D. HAYES'S DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-28 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-14 |
Time |
15:32 |
Sent To |
|
|
Notes |
2014-10-14 15:32:31 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-11-06 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2014-11-06 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-11-06 |
Time |
09:40 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-10-23 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2014-10-23 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-10-23 |
Time |
14:56 |
Sent To |
E |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy