Plan Review Details - Permit 14100239
Plan Review Stops For Permit 14100239
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-10-11 Cont ID  
Sent By shill Date 2014-10-11 Time 10:33 Rev Time 0.00
Received By shill Date 2014-10-11 Time 10:33 Sent To  
Notes
2014-10-11 10:36:53***PROVISO***
 ***ISSUED AT CONTRACTOR'S RISK****
  
 FBC R310, FBC EB 604.1. FOR SLEEPING ROOM WINDOWS, THE
 CLEAR EMERGENCY ESCAPE AND RESCUE OPENING CANNOT BE
 REDUCED BY MORE THAN 5%.
  
 BASED ON FLOOR PLAN, WINDOWS 2, 3, AND 4 ARE IN THE
 PROXIMITY OF A BEDROOM. EMERGENCY ESCAPE AND RESCUE
 OPENING NOT CLEAR.
  
 38" HIGH WINDOWS ARE SHOWN ON THE FLOOR PLAN. IF ANY OF
 THE 38" HIGH WINDOWS ARE LOCATED IN SLEEPING ROOMS,
 SUBMIT A REVISION WITH CALCULATIONS TO SHOW THAT THE
 CLEAR OPENING IS NOT REDUCED BY MORE THAN 5%.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-11 Cont ID  
Sent By shill Date 2014-10-11 Time 10:37 Rev Time 0.00
Received By shill Date 2014-10-11 Time 10:37 Sent To  
Notes
2014-10-07 13:22:57ROUTED TO MISC 1