Plan Review Stops For Permit 14100218 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-01-27 |
|
|
Cont ID |
|
Sent By |
JWITMER |
Date |
2015-01-27 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-01-27 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-12-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-03 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-03 |
Time |
10:20 |
Sent To |
|
|
Notes |
2014-12-03 10:25:27 | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | TUS.ASPX FOR PERMIT STATUS. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | 2014-11-13 09:34:40 | NEW SHEET SUBMITTED. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-10-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-10-17 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-17 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-10-28 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2014-10-28 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2014-10-28 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-10-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-10-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-10-14 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-01-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-01-27 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-01-13 |
Time |
08:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-12-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-03 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-11-12 |
Time |
09:33 |
Sent To |
|
|
Notes |
2014-11-13 09:34:03 | RE-SUBMITTAL SENT TO C28 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-29 |
Time |
04:37 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-06 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-12-02 |
|
|
Cont ID |
|
Sent By |
rbergsma |
Date |
2014-12-02 |
Time |
|
Rev Time |
0.75 |
Received By |
rbergsma |
Date |
2014-12-02 |
Time |
|
Sent To |
|
|
Notes |
2014-12-02 15:14:59 | PAGE M2.3 CORRECTED BY MECHANICAL PROCESSOR TO REMOVE | | SANITARY OPTION FOR A/C DRAIN IN ELEVATOR CONTROL | | CLOSET |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
rbergsma |
Date |
2014-10-10 |
Time |
|
Rev Time |
0.50 |
Received By |
rbergsma |
Date |
2014-10-10 |
Time |
|
Sent To |
|
|
Notes |
2014-10-10 10:47:41 | 307.2.1 CONDENSATE DISPOSAL. | | CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL | | BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED | | PLACE OF DISPOSAL. SUCH PIPING SHALL MAINTAIN A MINIMUM | | HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF NOT | | LESS THAN ONE-EIGHTH UNIT VERTICAL IN 12 UNITS | | HORIZONTAL (1-PERCENT SLOPE). CONDENSATE SHALL NOT | | DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS SO AS TO | | CAUSE A NUISANCE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-01-24 |
|
|
Cont ID |
|
Sent By |
TKLARGE |
Date |
2015-01-24 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-01-24 |
Time |
06:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2014-11-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-11-25 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-11-25 |
Time |
07:01 |
Sent To |
|
|
Notes |
2014-11-25 07:08:52 | 1) THERE WAS A PROVISO PLACED ON THE ORIGINAL PLANS | | THAT AN OIL SEPARATOR IS REQUIRED FOR THE DISCHARGE | | FROM THE ELEVATOR SUMP PER THE 2010 FPC SEC.1003.4. THE | | REVISED PLANS DO NOT SHOW AN OIL SEPARATOR NOR DO I SEE | | ANY VERIFICATION OF THIS INSTALLATION MEETING THE | | EXCEPTION TO SEC. 1003.4. CLARIFY. | | 2) THE NEW SHEETS SHALL BE INSERTED INTO THE PLANS. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-10-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-29 |
Time |
04:37 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-29 |
Time |
04:33 |
Sent To |
|
|
Notes |
2014-10-29 04:37:16 | 1) SHT. A002 - BACKING FOR GRAB BARS AT THE TUB BACK | | WALL SHALL BE 48 INCHES LONG MINIMUM.SHOW THE WIDTH OF | | THE BACKING. | | 2) SUPPLY A NARRATIVE THAT EXPLAINS THE CHANGES TO THE | | WATER AND SANITARY SYSTEMS. | | 3) SUBMIT REVISED SANITARY AND WATER RISERS THAT | | REFLECT THE CHANGES. | | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|