Plan Review Stops For Permit 14090987 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-10-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-20 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-20 |
Time |
06:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-03 |
Time |
18:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-03 |
Time |
18:48 |
Sent To |
|
|
Notes |
2014-10-03 18:50:58 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | BUILDING | | | | 1) CORRECT THE CODE EDITION AND THE WINDSPEED DATA ON | | SHEET N-1. THE APPLICABLE CODE IS THE 2010 FBC. THE | | WIND SPEED IS 170 MPH VULT AND THE EXPOSURE CATEGORY IS | | D. FBC - R 301.2.1 | | | | 2) SPECIFY WHICH OF THE BARRIER METHODS LISTED IN FBC - | | R4101.17 WILL BE USED TO PROTECT ACCESS FROM THE | | DWELLING TO THE POOL. | | | | 3) THE VALUATION ON THE PERMIT APPLICATION OF | | $13,000.00 FOR THE POOL IS TOO LOW. PLEASE SUBMIT AN | | ADEQUATE VALUE FOR THE NEW POOL AND EQUIPMENT. IF THE | | DEMO AND REMOVAL OF THE EXISTING POOL IS INCLUDED IN | | THIS PERMIT, THEN INCLUDE THE VALUE OF THAT WORK. | | | | 4) THE PERMIT CAN NOT BE ISSUED UNTIL THE POOL PLUMBING | | AND ELECTRICAL PERMIT APPLICATIONS ARE SUBMITTED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-10-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-20 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-20 |
Time |
06:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-03 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-03 |
Time |
18:47 |
Sent To |
|
|
Notes |
2014-10-03 18:56:10 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | ELECTRICAL | | | | 1) ON SHEET P-2 UNDER EQUIPMENT SELECTION IS LISTED " | | HEATER (ELECTRIC): JANDY 400 BTU GAS " . PLEASE CLARIFY | | IF THE POOL HEATER WILL BE GAS OR ELECTRIC AND CORRECT | | THE NOTE ACCORDINGLY. FBC 107.2.1 | | | | 2) IF THE POOL HEATER IS ELECTRIC, SUBMIT LOAD | | CALCULATIONS TO SHOW THAT THE EXISTING SERVICE WILL | | ACCOMMODATE THE NEW HEAT PUMP. NEC 220.40 | | | | 3) IF THE POOL HEATER IS ELECTRIC, SUBMIT THE CUT | | SHEETS WITH THE ELECTRIC REQUIREMENTS FOR THE POOL | | HEATER. NEC 680.9 | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2014-10-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-04 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-04 |
Time |
07:36 |
Sent To |
|
|
Notes |
2014-10-04 07:38:01 | NO GAS RISER PLAN WAS SUBMITTED AND NO APPLICATION FOR | | GAS WAS SUBMITTED. A SEPARATE PERMIT, APPLICATION AND | | REVIEW IS REQUIRED FOR GAS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-09-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-09-26 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-09-26 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-20 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-10-14 |
Time |
14:09 |
Sent To |
|
|
Notes |
2014-10-15 14:09:47 | RE-SUBMITTAL SENT TO TIM LARGE FOR PLUMBING REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-10-04 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-09-29 |
Time |
07:00 |
Sent To |
|
|
Notes |
2014-09-29 07:01:06 | INCOMING SENT TO POOL BOX. JW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2014-10-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-16 |
Time |
05:27 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-16 |
Time |
05:27 |
Sent To |
|
|
Notes |
2014-10-16 05:33:57 | ****PROVISO**** | | MANUF. SPEC SHEETS FOR POOL HEATER THAT SHOWS THE | | HEATER IS LISTED AND LABELED PER THE 2010 FLORIDA FUEL | | GAS CODE SEC. 301.3.SHALL BE ON THE JOBSITE FOR | | INSPECTOR. THE SPECS ATTACHED TO THE PLANS DO NOT SHOW | | THE HEATER IS LISTED & LABELED. INSPECTOR TO CHECK UNIT | | IN FIELD. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-10-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-02 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-02 |
Time |
10:23 |
Sent To |
|
|
Notes |
2014-10-02 11:32:15 | 1) SUBMIT 2 COPIES OF MANUF. SPECS FOR THE POOL HEATER | | THAT SHOW THE HEATER IS LISTED AND LABELED PER THE 2010 | | FUEL GAS CODE SEC. 301.3 . | | 2) INDICATE THE TYPE OF POOL BARRIER TO BE INSTALLED | | AROUND THE POOL. BARRIER TO COMPLY W/2010 FBCR, | | SEC.R4101.17. | | 3) SHT. N-1 - POOL EQUIPMENT DETAILS - REFER TO THE | | 2007 FBC AND 140 MPH WIND LOAD. REVISE NOTE TO READ 170 | | MPH AND 2010 FBC. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-09-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-09-26 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-09-26 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|