Plan Review Details - Permit 14090859
Plan Review Stops For Permit 14090859
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-10-10 Cont ID  
Sent By skennedy Date 2014-10-10 Time 17:08 Rev Time 0.00
Received By skennedy Date 2014-10-10 Time 17:07 Sent To E
Notes
2014-10-10 17:08:47TO DHAYES DESK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-10-29 Cont ID  
Sent By dhayes Date 2014-10-29 Time 13:20 Rev Time 0.00
Received By dhayes Date 2014-10-29 Time 13:20 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-10-14 Cont ID  
Sent By dhayes Date 2014-10-14 Time 11:55 Rev Time 0.00
Received By dhayes Date 2014-10-14 Time 11:54 Sent To  
Notes
2014-10-14 12:14:2410/14/2014
 PROJECT: LIFE IN PALM BEACH "SIGN "
 PERMIT#:
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) 600.3 LISTING.
 ELECTRIC SIGNS, SECTION SIGNS, AND OUTLINE LIGHTING ?
 FIXED, MOBILE, OR PORTABLE ? SHALL BE LISTED AND
 INSTALLED IN CONFORMANCE WITH THAT LISTING, UNLESS
 OTHERWISE APPROVED BY SPECIAL PERMISSION. INDICATE THE
 REQUIRED LISTING AND LABELING PER NEC 600.3 AND NEC
 110.3(B)
  
 2) NEC 600.5
 EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO PEDESTRIANS
 SHALL BE PROVIDED WITH AT LEAST ONE OUTLET SUPPLIED BY
 A BRANCH CIRCUIT RATED AT LEAST 20 AMPERES THAT
 SUPPLIES NO OTHER LOAD. INDICATE THE REQUIRED SIGN
 CIRCUIT IS EITHER EXISTING TO REMAIN OR PROPOSED TO BE
 INSTALLED UNDER THIS SCOPE. IF IT IS TO BE INSTALLED
 UNDER THIS SCOPE A SEPARATE PERMIT BY A QUALIFIED
 ELECTRICAL CONTRACTO IS REQUIRED.
  
 3) NEC 600.6(A)(1) LOCATION.
 DISCONNECTS. EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR
 FEEDER CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR
 OUT-LINE LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN
 EXTERNALLY OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL
 OPEN ALL UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN
 OR OUTLINE LIGHTING SYSTEM THAT IT CONTROLS. INDICATE
 THE REQUIRED DISCONNECT WITHIN SIGHT OF THE SIGN.
  
 4) FBC-E 505.2.4
 ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 SHALL
 HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN
 NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME
 CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES
 SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS
 OF POWER FOR A MINIMUM OF 10 HOURS. THE DEDICATED SIGN
 CIRCUIT SHALL COMPLY WITH THE PROVISIONS OF THE FBC-E
 505.2.4.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-17 Cont ID  
Sent By skennedy Date 2014-11-17 Time 08:39 Rev Time 0.00
Received By skennedy Date 2014-10-29 Time 13:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-14 Cont ID  
Sent By dhayes Date 2014-10-14 Time 12:14 Rev Time 0.00
Received By dhayes Date 2014-09-24 Time 17:07 Sent To  
Notes
2014-09-24 12:05:56ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2014-11-14 Cont ID  
Sent By eschneid Date 2014-11-14 Time 16:51 Rev Time 0.50
Received By eschneid Date 2014-11-14 Time 16:35 Sent To PC
Notes
2014-11-14 16:51:33PASSED
  
 ALLOWED: 33.75 SQ. FT. (27 SQ. FT. PLUS CITYPLACE ADMIN
 25% INCREASE)
 PROPOSED 33.6 SQ. FT.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-10-09 Cont ID  
Sent By eschneid Date 2014-10-09 Time 18:36 Rev Time 0.50
Received By eschneid Date 2014-10-09 Time 18:36 Sent To E
Notes
2014-10-09 19:55:40FAILED
  
 1) THIS IS NOT A DESIGNATED SIGN ZONE LOCATION IN THE
 CITYPLACE MASTER SIGN PLAN. THE SIGN ZONE(S) IS
 DIRECTLY OVER THE ARCHES. THE CITYPLACE MASTER SIGN
 PLAN ALLOWS VARIANCES FROM THIS PROVISION IF YOU
 PROVIDE A NOTARIZED LETTER FROM CITYPLACE THAT THEY
 HAVE GRANTED THE SPECIFIC VARIANCE TO MOVE THE SIGN IN
 THE HORIZONTAL PLANE OF THE SIGN ZONE.
  
 2) THE SIGN DIMENSIONS PROVIDED DO NOT INCLUDE ALL OF
 THE SIGN AREA THAT THE CITY MEASURES. ONE BOX SHALL BE
 DRAWN AROUND THE ENTIRE SIGN. THE TOP TO BOTTOM IS THE
 35 INCH HEIGHT OF THE PALM TREE. THE LEFT TO RIGHT -
 FROM THE PALM FROND TO THE LETTER H, WHICH INCLUDES THE
 SPACE BETWEEN THE TREE AND THE LETTER L SHALL BE
 PROVIDED.
  
 3) THE CITYPLACE MASTER SIGN PLAN MEASURES SIGNAGE
 ALLOWANCE AS FOLLOWS - ONE SQUARE FOOT OF SIGNAGE FOR
 EACH ONE LINEAR FOOT OF STORE FRONTAGE. THE STOREFRONT
 IS 27 FEET WIDE, SO THE SIGN MAY ONLY BE 27 SQ. FT.
 STAFF'S ROUGH CALCULATION BASED ON THE VALUES PROVIDED
 SHOW THE SIGN IN EXCESS OF 45 SQ. FT. CITYPLACE MAY
 APPROVE IN WRITING A VARIANCE TO INCREASE IN THE SIGN
 SQUARE FOOTAGE BY 25 PERCENT (UP TO 33.75 SQ. FT.)
  
 4) PLEASE PROVIDE THE DIMENSION THAT THE SIGN PROJECTS
 FROM THE WALL.
  
 A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL
 AT CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  