Plan Review Details - Permit 14090840
Plan Review Stops For Permit 14090840 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-10-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-10-01 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-01 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-09-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-24 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-24 |
Time |
10:59 |
Sent To |
|
|
Notes |
2014-09-24 12:50:24 | DATE: 9/24/2014 | | PROJECT: NORTHPOINT SUITE 340 | | PERMIT#: 14090840 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: PROVISO | | | | 1) FBC-ENERGY | | 505.2 LIGHTING CONTROLS (MANDATORY). | | LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS | | REQUIRED IN SECTIONS 505.2.1, 505.2.2, 505.2.3 AND | | 505.2.4. | | 505.2.2 AUTOMATIC LIGHTING SHUTOFF. | | BUILDINGS LARGER THAN 5,000 SQUARE FEET (465 M2) SHALL | | BE EQUIPPED WITH AN AUTOMATIC CONTROL DEVICE TO SHUT | | OFF LIGHTING IN THOSE AREAS. | | REVISE PLANS AND INSTALLATION IN COMPLIANCE WITH | | SECTION 505 AS DESRIBED ABOVE. | | | | 2) VERIFY DEDICATED SPACE AND WORKING CLEARANCE IN THE | | ELECTRICAL ROOM WHEN INSTALLING THE NEW PANEL RL AS | | REQUIRED BY THE NEC 110.26 | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-10-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-10-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-10-06 |
Time |
10:20 |
Sent To |
|
|
Notes |
2014-10-06 10:49:27 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | SHEET A 3.01, DOOR 07 SHALL NOT SWING INTO THE HALLWAY | | MORE THAN 1/2 OF THE HALLWAY WIDTH OR IT SHALL NOT BE | | INSTALLED TO SWING INTO HALLWAY. | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | COMPLIANCE. | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | CONSTRUCTION PERIOD. | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-08 |
Time |
05:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-09-23 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-09-26 |
|
|
Cont ID |
|
Sent By |
rbergsma |
Date |
2014-09-26 |
Time |
|
Rev Time |
0.50 |
Received By |
rbergsma |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-08 |
Time |
05:54 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-08 |
Time |
05:54 |
Sent To |
|
|
Notes |
|
|
|