|
 |
 |
 |
 |
 |
Plan Review Details - Permit 14090826
Plan Review Stops For Permit 14090826 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-20 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-20 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-11 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-11 |
Time |
12:22 |
Sent To |
|
|
Notes |
2014-10-11 12:27:54 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FBC 2010 RESIDENTIAL 301 | | | | 1. SUBSTRATE IS NOT CLEAR. "CONCRETE BLOCK" IS | | SPECIFIED FOR OPENINGS 1-5. FOR VERTICAL INSTALLATIONS, | | IS THIS CONCRETE BLOCK (MASONRY) TOP AND BOTTOM, OR | | CONCRETE TOP, BLOCK BOTTOM (TYPICAL OF CBS STRUCTURES)? | | | | FOR HORIZONTAL INSTALLATION #1, FILLED CELLS ON EACH | | SIDE WOULD REQUIRE USE OF THE "MASONRY" ANCHOR SPACING. | | FOR THE CONNECTION TYPES SELECTED, SUBSTRATE MUST BE | | CONCRETE. | | | | CONNECTION TYPES 1 AND 6 REQUIRE A CONCRETE SUBSTRATE | | (SEE ANCHOR CHART, MASONRY COLUMN STATES "NA" FOR | | SPACING). | | | | CONNECTION TYPE 2 ALLOWS A MASONRY SUBSTRATE, BUT 7" IS | | REQUIRED, 9" PROPOSED. | | | | PLEASE CLARIFY SUBSTRATE, REVISE ANCHOR SPACING AND | | CONNECTION TYPE AS APPLICABLE. | | | | 2. REVISE FLOOR PLAN TO PROVIDE ROOM DESIGNATIONS FOR | | OPENINGS/DOORS MARKED EGRESS FBC R 310.4. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-09-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-30 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-30 |
Time |
10:00 |
Sent To |
|
|
Notes |
2014-09-30 10:04:40 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 2010 RESIDENTIAL 301, PROVIDE CALCULAITNS FOR | | DESIGN PRESSURES, OR PROVIDE SIGNED AND SEALED | | ENGINEERING, OR USE THE PRESSURES IN TABLE R301.2(2) AS | | ADJUSTED BY 301.2(3). SEE OPENING 3. -39 PSF IS | | PROPOSED, BUT FOR EXPOSURE C, 25' MRH, 10 SF A DESIGN | | PRESSURE OF -45.8 IS REQUIRED. | | | | 2. THE COLUMN "SHUTTER MOUNTING CONNECTION TYPE PER | | PRODUCT APPROVAL" IS BLANK. PLEASE COMPLETE SO PROPOSED | | ANCHORING FOR EACH OPENING CAN BE REVIEWED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-20 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-14 |
Time |
13:17 |
Sent To |
|
|
Notes |
2014-10-14 13:17:39 | TO SHILL DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-10-11 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-10-11 |
Time |
12:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-30 |
Time |
10:04 |
Rev Time |
|
Received By |
shill |
Date |
2014-09-23 |
Time |
|
Sent To |
|
|
Notes |
2014-09-23 12:50:48 | BLDG <5000 | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |