Plan Review Details - Permit 14090594
Plan Review Stops For Permit 14090594 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-12-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-09 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-12-09 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-22 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-22 |
Time |
10:44 |
Sent To |
|
|
Notes |
2014-09-22 12:35:31 | ****CORRECTIONS**** | | REVISED 10/28 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. SCOPE OF PERMIT IS "ROADWAY & PARKING LOT | | CONSTRUCTION." SEE SHEET 1 OF 1 (TOPO SURVEY), SHEET C1 | | PREPARED BY RAVI KADAMBALA, PE. PROPOSED WORK IS NOT | | CLEARLY DEPICTED ON EITHER SHEET. TYPICALLY A SECTION | | WHICH CORRLATES WITH THE ENLARGED DETAIL IS INCLUDED ON | | THE LARGER OVERALL SITE PLAN, FBC 107. | | | | 10/28/14 UNABLE TO LOCATE PLANS TO DISCUSS WITH | | ENGINEER. REVIEW WILL NOT FAIL RESUBMITTAL DUE TO THIS | | COMMENT (ENGINEER WILL SEND EMAIL WITH SHEETS FOR | | PRELIMINARY REVIEW AND WILL INCLUDE A RESPONSE LETTER | | STATING WHERE THIS INFORMATINON CAN BE FOUND ON THE | | PLAN). | | | | 2. ACCESSIBLE PARKING SPACES NOT SHOWN. SEE FBC 2010 | | ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 (PARKING | | SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE ROUTE). | | I WAS UNABLE TO LOCATE AN EXCEPTION TO THIS | | REQUIREMENT. IF YOU WISH TO DISCUSS THIS, PLEASE FEEL | | FREE TO CONTACT ME. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2014-12-05 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2014-12-05 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2014-12-05 |
Time |
10:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2014-10-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2014-10-16 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2014-10-16 |
Time |
08:14 |
Sent To |
|
|
Notes |
2014-10-16 08:50:53 | ENGINEERING DEPT COMMENTS | | | | 1. AN ENGINEERING DEVELOPMENT PERMIT APPLICATION WOULD | | NORMALLY BE REQUIRED. HOWEVER, THIS PROJECT IS COVERED | | BY THE POWER PLANT SITING ACT AND THE CITY HAD THE | | OPPORTUNITY TO COMMENT ON THE PROPOSAL DURING THE | | REVIEW OF AMENDMENT AMI14-072, WHICH WAS APPROVED BY | | DEP ON JUNE 24, 2014. | | | | 2. INDICATE THE MATERIAL AND MINIMUM COVER PROPOSED FOR | | THE NEW 2-INCH POTABLE WATER LINE EXTENSION, ALSO, | | REVISE DETAIL B ON SHEET CD-1 TO INCLUDE THE 2" X 1" | | DOUBLE STRAP SADDLE AND GATE VALVE CALLED FOR ON SHEET | | C-4. | | | | 3. NEW STRIPING AND PARKING LOT CONFIGURATION MUST | | COMPLY WITH CITY OF WEST PALM BEACH CODE OF ORDINANCES, | | ARTICLE XV, SECTIONS 94-485 AND 94-443(C)(5)(B), FIGURE | | XIV-2. PLEASE LABEL THE PARKING AISLE AND PARKING STALL | | DIMENSIONS. ALSO INCLUDE A DETAIL SHOWING COMPLIANCE | | WITH THE CITY CODE (DOUBLE 4 INCH STRIPES WITH A 12 | | INCH SPACE BETWEEN THE STRIPES). | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | ENGINEERING & PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-12-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-12-09 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-11-10 |
Time |
07:18 |
Sent To |
|
|
Notes |
2014-11-12 07:20:00 | INCOMING SENT TO ZONING BOX. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-10-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2014-10-16 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2014-10-16 |
Time |
10:27 |
Sent To |
|
|
Notes |
2014-09-22 12:36:03 | 9/22 TO ZONING | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-12-04 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2014-12-04 |
Time |
09:26 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2014-12-04 |
Time |
09:26 |
Sent To |
ENG |
|
Notes |
2014-12-04 09:46:22 | PASSED | | | | 1) THE FOLLOWING ITEMS REQUIRE SEPARATE PERMITS WITH | | PLANS (NEITHER OF THESE ITEMS HAVE BEEN REVIEWED AS | | PART OF THIS SUBMITTAL): | | | | A. SIGNAGE - FOR THE SIGNAGE PROPOSED ALONG JOG ROAD, A | | SURVEY/SITE PLAN SHOWING THE SIGN LOCATIONS WITH A FIVE | | (5) FOOT SETBACK TO THE PROPERTY LINES IS REQUIRED. | | | | B. THE SITE LIGHTING AND CAMERAS, INCLUDING THE POLES. | | PLEASE REMEMBER TO INCLUDE PHOTOMETRIC PLANS AND TO | | VERIFY NO GLARE WILL BE CREATED ONTO THE TURNPIKE. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2014-10-08 |
Time |
14:31 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2014-10-08 |
Time |
14:31 |
Sent To |
ENG |
|
Notes |
2014-10-08 14:52:45 | THE FOLLOWING ITEMS REQUIRE SEPARATE PERMITS WITH | | PLANS: | | | | 1) THE SIGNAGE PROPOSED ALONG JOG ROAD. A SURVEY | | SHOWING THE SIGN LOCATIONS IN RELATIONSHIP TO THE | | PROPERTY LINES IS REQUIRED. PLEASE NOTE THAT A FIVE (5) | | FOOT SETBACK IS REQUIRED. | | | | 2) THE SITE LIGHTING AND CAMERAS, INCLUDING THE POLES. | | PLEASE REMEMBER TO INCLUDE PHOTOMETRIC PLANS AND TO | | VERIFY NO GLARE WILL BE CREATED ONTO THE TURNPIKE. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |