Plan Review Stops For Permit 14090490 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2014-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-06 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-06 |
Time |
14:05 |
Sent To |
|
|
Notes |
2014-11-06 14:05:42 | ACCORDING TO AERIAL VIEW FROM THE PROPERTY APPRAISAL IT | | LOOKS LIKE THE EXISTING WINDOWS ARE AWNING TYPE | | WINDOWS. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
|
Date |
2014-10-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-31 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-31 |
Time |
17:24 |
Sent To |
|
|
Notes |
2014-10-31 17:28:00 | | | ***REVIEW IN PROGRESS.... | | | | | | 1-SPECIFY ANCHOR TO BE USED. | | | | 2- SPECIFY THE EXISTING BEDROOM WINDOWS TYPE AND SIZE | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS OF | | SEC. 604 OF 2010 FBC-EXISTING BUILDING CODE. | | REPEAT COMMENT. NOT ADDRESSED. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. THERE ARE NO 12 WINDOWS TO BE REPLACED AS STATED | | IN THE PERMIT APPLICATION. ACCORDING TO SKETCH | | SUBMITTED, THERE ARE 19 WINDOWS AND 7 WINDOW MULLIONS | | TO BE REPLACED. IN ADDITION, THERE WILL BE HURRICANE | | PANELS INSTALLED ALSO. VALUATION TO INCLUDE ALL LABOR, | | MATERIALS, AND CONTRACTOR'S OVERHEAD AND PROFIT AS | | REQUIRED BY SEC. 1069.3 CITY AMENDMENTS TO FBC. UPDATE | | VALUATION AS REQUIRED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-10-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-07 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-07 |
Time |
10:54 |
Sent To |
|
|
Notes |
2014-10-07 10:56:46 | RESIDENTIAL (R3) WINDOW ALTERATION, SECOND BUILDING | | REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE SHUTTERS INSTALLATION SCHEDULE. | | INFORMATION SHOWN IN THE SHUTTERS INSTALLATION SCHEDULE | | SUBMITTED IS INCOMPLETE. IT DOESN'T PROVIDE ANY | | INFORMATION CONCERNING THE PROPOSED INSTALLATION. SEC. | | 107.2.1 CITY AMENDMENTS TO FBC. | | REPEAT COMMENT. NOT ADDRESSED. | | | | 2- SKETCH SUBMITTED: CLEARLY SPECIFY THE EXISTING | | BEDROOM WINDOWS TYPE AND SIZE TO VERIFY COMPLIANCE WITH | | THE EGRESS REQUIREMENTS OF SEC. 604 OF 2010 | | FBC-EXISTING BUILDING CODE. | | REPEAT COMMENT. NOT ADDRESSED. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. THERE ARE NO 12 WINDOWS TO BE REPLACED AS STATED | | IN THE PERMIT APPLICATION. ACCORDING TO SKETCH | | SUBMITTED, THERE ARE 19 WINDOWS AND 7 WINDOW MULLIONS | | TO BE REPLACED. IN ADDITION, THERE WILL BE HURRICANE | | PANELS INSTALLED ALSO. VALUATION TO INCLUDE ALL LABOR, | | MATERIALS, AND CONTRACTOR'S OVERHEAD AND PROFIT AS | | REQUIRED BY SEC. 1069.3 CITY AMENDMENTS TO FBC. UPDATE | | VALUATION AS REQUIRED. | | REPEAT COMMENT. NOT ADDRESSED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICE DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-09-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-09-17 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-09-17 |
Time |
08:44 |
Sent To |
|
|
Notes |
2014-09-17 08:53:43 | RESIDENTIAL (R3) WINDOW ALTERATION, BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE SHUTTERS INSTALLATION SCHEDULE. | | INFORMATION SUBMITTED IS INCOMPLETE. IT DOESN'T PROVIDE | | ANY INFORMATION CONCERNING THE PROPOSED INSTALLATION. | | SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | 2- SKETCH SUBMITTED: CLEARLY IDENTIFY ROOM DESIGNATIONS | | (FOR EXAMPLE BEDROOM, KITCHEN, LIVING ROOM, ETC). AND | | CLEARLY SPECIFY THE EXISTING BEDROOM WINDOWS TYPE AND | | SIZE TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS | | OF SEC. 604 OF 2010 FBC-EXISTING BUILDING CODE. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. THERE ARE NO 12 WINDOWS TO BE REPLACED AS STATED | | IN THE PERMIT APPLICATION. ACCORDING TO SKETCH | | SUBMITTED, THERE ARE 19 WINDOWS AND 7 WINDOW MULLIONS | | TO BE REPLACED. IN ADDITION, THERE WILL BE HURRICANE | | PANELS INSTALLED ALSO. VALUATION TO INCLUDE ALL LABOR, | | MATERIALS, AND CONTRACTOR'S OVERHEAD AND PROFIT AS | | REQUIRED BY SEC. 1069.3 CITY AMENDMENTS TO FBC. UPDATE | | VALUATION AS REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICE DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-06 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-06 |
Time |
14:01 |
Sent To |
|
|
Notes |
2014-11-06 14:02:43 | MET W/ MIKE TO GO OVER COMMENTS. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-10-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-31 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-28 |
Time |
13:50 |
Sent To |
|
|
Notes |
2014-10-28 13:52:40 | INCOMING SENT TO J. GOMEZ. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-07 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-03 |
Time |
13:35 |
Sent To |
|
|
Notes |
2014-10-03 13:35:56 | TO JG DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-09-17 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-09-17 |
Time |
08:44 |
Sent To |
|
|
Notes |
2014-09-15 13:24:36 | ROUTED TO BLDG $5000 & UNDER |
|
|