Plan Review Details - Permit 14090358
Plan Review Stops For Permit 14090358 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-09-16 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-16 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-16 |
Time |
11:09 |
Sent To |
|
|
Notes |
2014-09-16 11:20:01 | DATE: 9/16/2014 | | PROJECT: EVERNIA PLACE | | PERMIT#: 14090358 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: PROVISO | | | | 1) NEC 600.6(A)(1) | | EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER | | CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE | | LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY | | OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL | | UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN OR | | OUTLINE LIGHTING SYSTEM THAT IT CONTROLS. | | | | 2) FBC-E 505.2.4 | | ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 SHALL | | HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN | | NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME | | CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES | | SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS | | OF POWER FOR A MINIMUM OF 10 HOURS. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-15 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-15 |
Time |
07:24 |
Sent To |
|
|
Notes |
2014-09-15 08:18:17 | DATE: 9/15/2014 | | PROJECT: EVERNIA PLACE | | PERMIT#: 14090358 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 | | SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT | | OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & | | TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME | | SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING | | DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E | | 505.2.4. INDICATE ON THE PLANS THE INSTALATION AND USE | | OF A TIMECLOCK AND PHOTO SENSOR FOR CONTROL OF THE SIGN | | AND STREET LIGHTING CIRCUITS AND PER THE FBC-E 505.2.4. | | | | 2) THE GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE LESS | | THAN GIVEN IN THE NEC TABLE 250.66. REVISE PLANS | | ACCORDINGLY. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-16 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-16 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-16 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-15 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-15 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-11 |
Time |
09:01 |
Sent To |
|
|
Notes |
2014-09-12 09:01:50 | SENT TO ELECTRICAL |
|
|
|