Plan Review Details - Permit 14090220
Plan Review Stops For Permit 14090220
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2015-10-20 Cont ID  
Sent By jgomez Date 2015-10-20 Time 13:17 Rev Time 0.00
Received By jgomez Date 2015-10-20 Time 13:16 Sent To  
Notes
2015-10-20 13:28:40BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE COMPLETE HANDRAIL AND GUARDRAILS DRAWINGS
 (PRIOR TO INSTALLATION) FROM SPECIALTY ENGINEER AS
 SPECIFIED BY THE ENGINEER OF RECORD. PLANS TO BE
 APPROVED BY ENGINEER OF RECORD PRIOR TO SUBMITTAL TO
 THIS OFFICE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2015-07-21 Cont ID  
Sent By jgomez Date 2015-07-21 Time 19:14 Rev Time 0.00
Received By jgomez Date 2015-07-21 Time 19:14 Sent To  
Notes
2015-07-21 19:20:05RESIDENTIAL (R3) ADDITION, FOURTH BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- NEW FIRST FLOOR PLAN ON SHEET S-1: INFORMATION ADDED
 BY THE STAIRWAY IS NOT LEGIBLE. LETTERING IS TOO SMALL.
 REVISE AS REQUIRED. SEC. 107.2.1.4 CITY AMENDMENTS.
 (REPEAT COMMENT. NOT ADDRESSED AT ALL).
  
 ****NOTE:
 FIFTH REVIEW WAS SUSPENDED. BASED ON PRELIMINARY REVIEW
 OF THE RE-SUBMITTED PLANS, THE STRUCTURAL DETAILS SHOWN
 ON PLANS DON'T WORK AND ARE UNCOORDINATED. PLANS WERE
 SENT TO STEVE KENNEDY FOR PEER REVIEW.
  
  
  
 ***REVIEW IN PROGRESS....
  
 2- SHEET S-2:
 A) COLUMN BASE CONNECTOR LCB66 SPECIFIED FOR LVL BEAMS
 DOESN'T WORK. SIZE OF BEAM IS BIGGER THAN THE W1
 DIMENSION OF THE CONNECTOR. ENGINEER TO SPECIFY
 PROPOSED SIZE OF CONNECTOR. ENGINEER TO SPECIFY THE
 UPLIFT LOADS AT THE ENDS OF EACH BEAM AND PROVIDE
 COMPLETE ENGINEERING ANALYSIS SHOWING HOW THE SPECIFIED
 CONNECTOR IS APPROPRIATE FOR THE INSTALLATION. SEC.
 107.2.1.3 CITY AMENDMENTS.
  
 B) CONNECTOR "B" SPECIFIED ON THE CONNECTOR SCHEDULE
 DOESN'T MATCH PROPOSED INSTALLATION AND IS INCOMPLETE.
 PROVIDE COMPLETE DETAIL THAT MATCHES PROPOSED
 INSTALLATION AND PROVIDE COMPLETE DETAIL AND
 SPECIFICATIONS FOR THE PROPOSED STEEL CONNECTOR. SEC.
 R301.1 CITY AMENDMENTS AND SEC. 107.2.1 CITY
 AMENDMENTS.
  
 C) DETAIL C/S2 STAIR WALL DETAIL: PROVIDE COMPLETE AND
 CLEAR DETAIL OF THE STEEL BRACKET. SPECIFY ALL
 DIMENSIONS. PROVIDE DETAIL THAT MATCHES PROPOSED
 INSTALLATION. ALSO, COORDINATE WITH CONNECTOR "C".
 ELEVATION VIEW OF CONNECTOR "C" DOESN'T SHOW HOW IS THE
 STEEL BRACKET ATTACHED TO THE CONCRETE BEAM. SEC.
 R301.1 AND SEC. 107.2.1 CITY AMENDMENTS.
  
 D) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE PRE-CAST LINTELS SPECIFIED ON
 DETAIL C/S2 STAIR WALL DETAIL.
  
 E) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONNECTOR OF THE WOOD POST SHOWN ON DETAIL C/S2 STAIR
 WALL DETAIL. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 F) PROVIDE GUARDRAIL COMPLETE CONSTRUCTION AND
 INSTALLATION DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE LIVE LOADS REQUIRED BY TABLE R301.5
 AND SEC. R312 OF 2010 FBC-RESIDENTIAL. PROVIDE
 ENGINEERING CALCULATIONS SHOWING HOW THE SPECIFIED POST
 CONNECTOR AND THE TOE NAILED #12 SCREWS AS SHOWN ON
 DETAIL A/S2 WILL RESIST THE REQUIRED LOADS. SEC.
 107.2.1.3 CITY AMENDMENTS. AND, PROVIDE COMPLETE
 SPECIFICATIONS FOR THE NAILING OF THE RAILING PICKETS.
  
 G) ALL THE STAIRS INFORMATION IS MISSING. PROVIDE
 COMPLETE INFORMATION SHOWING COMPLIANCE WITH SEC.
 R311.7.4 OF 2010 FBC-RESIDENTIAL.
  
 H) PROVIDE COMPLETE FASTENING SPECIFICATIONS FOR THE
 INSTALLATION OF THE 1 X 6 WOOD DECKING AND 1 X 6
 CYPRESS CEILING. SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 I) CLARIFY IF DECK IS GOING TO BE DESIGNED WITHOUT
 WATERPROOFING. SEC. 107.2.1 CITY AMENDMENTS. OTHERWISE,
 PROVIDE COMPLETE INFORMATION INCLUDING PRODUCT APPROVAL
 AND SIGNED AND SEALED RAS 117 CALCULATIONS IF REQUIRED.
 DCA RULE 9N-3.
  
 J) IT'S NOT CLEAR WHY SUBMITTING PRODUCT APPROVALS FOR
 SINGLE HUNG WINDOWS, WINDOW MULLIONS. THE PLANS DON'T
 SHOW ANY SCOPE OF WORK OF NEW WINDOWS OR WINDOW
 REPLACEMENT. IF THERE IS GOING TO BE WINDOW
 REPLACEMENT, THEN REVISE PLANS AS REQUIRED SHOWING
 AREAS OF WORK. SPECIFY SIZE SIZE AND TYPE OF EXISTING
 WINDOWS AND PROPOSED WINDOWS. SEC. 604 OF 2010
 FBC-EXISTING BUILDING. REVISE VALUATION DECLARED IN THE
 PERMIT APPLICATION ACCORDINGLY. REPEAT COMMENT.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT.
  
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS....
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2015-06-15 Cont ID  
Sent By jgomez Date 2015-06-13 Time 11:48 Rev Time 0.00
Received By jgomez Date 2015-06-13 Time 11:47 Sent To  
Notes
2015-06-13 11:59:46RESIDENTIAL (R3) ADDITION, FOURTH BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- NEW FIRST FLOOR PLAN ON SHEET S-1: INFORMATION ADDED
 BY THE STAIRWAY IS NOT LEGIBLE. LETTERING IS TOO SMALL.
 REVISE AS REQUIRED. SEC. 107.2.1.4 CITY AMENDMENTS.
  
 2- SHEET S-2:
 A) COLUMN BASE CONNECTOR LCB66 SPECIFIED FOR LVL BEAMS
 DOESN'T WORK. SIZE OF BEAM IS BIGGER THAN THE W1
 DIMENSION OF THE CONNECTOR. ENGINEER TO SPECIFY
 PROPOSED SIZE OF CONNECTOR. ENGINEER TO SPECIFY THE
 UPLIFT LOADS AT THE ENDS OF EACH BEAM AND PROVIDE
 COMPLETE ENGINEERING ANALYSIS SHOWING HOW THE SPECIFIED
 CONNECTOR IS APPROPRIATE FOR THE INSTALLATION. SEC.
 107.2.1.3 CITY AMENDMENTS.
  
 B) CONNECTOR "B" SPECIFIED ON THE CONNECTOR SCHEDULE
 DOESN'T MATCH PROPOSED INSTALLATION AND IS INCOMPLETE.
 PROVIDE COMPLETE DETAIL THAT MATCHES PROPOSED
 INSTALLATION AND PROVIDE COMPLETE DETAIL AND
 SPECIFICATIONS FOR THE PROPOSED STEEL CONNECTOR. SEC.
 R301.1 CITY AMENDMENTS AND SEC. 107.2.1 CITY
 AMENDMENTS.
  
 C) DETAIL C/S2 STAIR WALL DETAIL: PROVIDE COMPLETE AND
 CLEAR DETAIL OF THE STEEL BRACKET. SPECIFY ALL
 DIMENSIONS. PROVIDE DETAIL THAT MATCHES PROPOSED
 INSTALLATION. ALSO, COORDINATE WITH CONNECTOR "C".
 ELEVATION VIEW OF CONNECTOR "C" DOESN'T SHOW HOW IS THE
 STEEL BRACKET ATTACHED TO THE CONCRETE BEAM. SEC.
 R301.1 AND SEC. 107.2.1 CITY AMENDMENTS.
  
 D) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE PRE-CAST LINTELS SPECIFIED ON
 DETAIL C/S2 STAIR WALL DETAIL.
  
 E) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONNECTOR OF THE WOOD POST SHOWN ON DETAIL C/S2 STAIR
 WALL DETAIL. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 F) PROVIDE GUARDRAIL COMPLETE CONSTRUCTION AND
 INSTALLATION DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE LIVE LOADS REQUIRED BY TABLE R301.5
 AND SEC. R312 OF 2010 FBC-RESIDENTIAL. PROVIDE
 ENGINEERING CALCULATIONS SHOWING HOW THE SPECIFIED POST
 CONNECTOR AND THE TOE NAILED #12 SCREWS AS SHOWN ON
 DETAIL A/S2 WILL RESIST THE REQUIRED LOADS. SEC.
 107.2.1.3 CITY AMENDMENTS. AND, PROVIDE COMPLETE
 SPECIFICATIONS FOR THE NAILING OF THE RAILING PICKETS.
  
 G) ALL THE STAIRS INFORMATION IS MISSING. PROVIDE
 COMPLETE INFORMATION SHOWING COMPLIANCE WITH SEC.
 R311.7.4 OF 2010 FBC-RESIDENTIAL.
  
 H) PROVIDE COMPLETE FASTENING SPECIFICATIONS FOR THE
 INSTALLATION OF THE 1 X 6 WOOD DECKING AND 1 X 6
 CYPRESS CEILING. SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 I) CLARIFY IF DECK IS GOING TO BE DESIGNED WITHOUT
 WATERPROOFING. SEC. 107.2.1 CITY AMENDMENTS. OTHERWISE,
 PROVIDE COMPLETE INFORMATION INCLUDING PRODUCT APPROVAL
 AND SIGNED AND SEALED RAS 117 CALCULATIONS IF REQUIRED.
 DCA RULE 9N-3.
  
 J) IT'S NOT CLEAR WHY SUBMITTING PRODUCT APPROVALS FOR
 SINGLE HUNG WINDOWS, WINDOW MULLIONS. THE PLANS DON'T
 SHOW ANY SCOPE OF WORK OF NEW WINDOWS OR WINDOW
 REPLACEMENT. IF THERE IS GOING TO BE WINDOW
 REPLACEMENT, THEN REVISE PLANS AS REQUIRED SHOWING
 AREAS OF WORK. SPECIFY SIZE SIZE AND TYPE OF EXISTING
 WINDOWS AND PROPOSED WINDOWS. SEC. 604 OF 2010
 FBC-EXISTING BUILDING. REVISE VALUATION DECLARED IN THE
 PERMIT APPLICATION ACCORDINGLY. REPEAT COMMENT.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT.
  
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS....
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-05-15 Cont ID  
Sent By J. Gomez Date 2015-05-15 Time 07:40 Rev Time 0.00
Received By jgomez Date 2015-05-15 Time 07:40 Sent To  
Notes
2015-05-15 07:41:40RESIDENTIAL (R3) ADDITION, THIRD BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 NOTE: ENGINEER IS INFORMED VIA THIS CHECKLIST THAT ONE
 SET OF PLANS WILL BE FORWARDED TO THE BOARD OF
 ENGINEERS FOR REVIEW.
  
 1- SHEET S-1: PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE COLUMNS THAT ARE LOCATED AT THE
 OPENING BELOW THE NEW STAIRWAY. THERE ARE SPECS FOR
 COLUMN C3 BUT NO INFORMATION FOR THOSE COLUMNS. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 2- SHEET S-2:
 A) COLUMN BASE CONNECTOR LCB66 SPECIFIED FOR ALL LVL
 BEAMS DOESN'T WORK. ALSO, ANOTHER COLUMN BASE CONNECTOR
 CB7-7.5 WAS SPECIFIED. THIS ONE DOESN'T WORK EITHER.
 WHY ARE THERE TWO DIFFERENT COLUMN CONNECTORS?. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 B) COLUMN BASE CONNECTOR CB66 SPECIFIED FOR ALL 6X6
 GUARDRAILS POSTS DOESN'T WORK FOR THE PROPOSED
 INSTALLATION. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 C) DETAIL C/S2: DIMENSIONS FOR THE STEEL BRACKET ARE
 INCOMPLETE AND THE 4 1/2" DIMENSIONS DOESN'T WORK FOR
 THE SIZE OF THE LVL BEAM. SEC. 107.2.1 CITY AMENDMENTS.
  
 D) THERE ARE NOT SPECIFICATIONS FOR THE TOP BEAMS OF
 THE NEW WALLS FOR THE NEW STAIRWAY. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 E) INFORMATION SHOWN ON SECTION/DETAIL A/S2 DOESN'T
 MATCH LOCATION KEYED ON THE 2ND FLOOR LAYOUT. SEC.
 107.2.1 CITY AMENDMENTS.
  
 F) THERE IS A NOTE ON THE FLOOR FRAMING PLAN STATING
 "SEE TRUSS COMPANY ENGINEERED ATTACHED". WHERE IS IT?.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 G) PROVIDE GUARDRAIL COMPLETE CONSTRUCTION AND
 INSTALLATION DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE LIVE LOADS REQUIRED BY TABLE R301.5
 AND SEC. R312 OF 2010 FBC-RESIDENTIAL. THERE ARE NOT
 DETAILS SHOWING CONSTRUCTION AND INSTALLATION.
  
 H) HANDRAIL L DETAIL PROVIDED DOESN'T SEEM TO MATCH
 PROPOSED INSTALLATION. THIS TYPE OF DETAIL IS TYPICAL
 FOR STAIRWAYS WITH NO SIDE WALLS. REVISE CLARIFY AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 I) STAIRS DETAILS: (1) SIZE OF TREAD DOESN'T COMPLY
 WITH SEC. R311.7.4.1 OF 2010 FBC-RESIDENTIAL.
  
 (2) NOSING DETAIL DOESN'T COMPLY WITH SEC. R311.7.4.3
 OF 2010 FBC-RESIDENTIAL.
  
 (3) SPECIFY BEAM SIZE. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 (4) SECTION A IS NOT CLEAR. WHERE IS THIS SECTION TAKEN
 AT?. SEC. 107.2.1 CITY AMENDMENTS.
  
 (5) HOW IS THE STRINGER ATTACHED TO THE TOP BEAM?. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 J) DETAIL B/S2: (1) WHERE IS THIS SECTION TAKEN AT?.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 (2) PROVIDE COMPLETE FASTENING SPECIFICATIONS FOR THE
 INSTALLATION OF THE 1 X 6 WOOD DECKING AND 1 X 6
 CYPRESS CEILING. SEC. R301 OF 2010 FBC-RESIDENTIAL.
 NOTE: CYPRESS CEILING FASTENING: CLARIFY HOW ARE 8D
 FINISH NAILS FASTENED AT 12" O.C. IF THE FLOOR JOISTS
 ARE SPACED AT 16" O.C.?. IS THERE ONLY ONE NAIL PER T &
 G ATTACHED TO THE 2X12 JOIST?. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 (3) CLARIFY IF DECK IS GOING TO BE DESIGNED WITHOUT
 WATERPROOFING. SEC. 107.2.1 CITY AMENDMENTS. OTHERWISE,
 PROVIDE COMPLETE INFORMATION INCLUDING PRODUCT APPROVAL
 AND SIGNED AND SEALED RAS 117 CALCULATIONS IF REQUIRED.
 DCA RULE 9N-3.
  
 (4) VERTICAL REINFORCEMENT SHOWN DOESN'T MATCH
 INFORMATION SHOWN ON COLUMN SCHEDULE. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 3- ENGINEER IS USING OLD SEAL. NEED TO USE CURRENT SEAL
 WITH THE WORDING "LICENSE" NOT "CERTIFICATE". SEC.
 61G15-23.001. F.A.C. REPEAT COMMENT. ENGINEER USED OLD
 SEAL AGAIN.
  
 4- IT'S NOT CLEAR WHY SUBMITTING PRODUCT APPROVALS FOR
 SINGLE HUNG WINDOWS, WINDOW MULLIONS. THE PLANS DON'T
 SHOW ANY SCOPE OF WORK OF NEW WINDOWS OR WINDOW
 REPLACEMENT. IF THERE IS GOING TO BE WINDOW
 REPLACEMENT, THEN REVISE PLANS AS REQUIRED SHOWING
 AREAS OF WORK. SPECIFY SIZE SIZE AND TYPE OF EXISTING
 WINDOWS AND PROPOSED WINDOWS. SEC. 604 OF 2010
 FBC-EXISTING BUILDING. REVISE VALUATION DECLARED IN THE
 PERMIT APPLICATION ACCORDINGLY. REPEAT COMMENT.
  
 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS....
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-04-14 Cont ID  
Sent By jgomez Date 2015-04-14 Time 18:41 Rev Time 0.00
Received By jgomez Date 2015-04-14 Time 07:50 Sent To  
Notes
2015-04-13 18:59:43RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW
 COMMENTS .
 CODE: 2010 FBC.
  
 (NOTE: THESE COMMENTS ARE FOR A NEW SET OF CONSTRUCTION
 DRAWINGS SUBMITTED FROM ANOTHER DESIGN PROFESSIONAL).
  
 1- A) ENGINEER OF RECORD TO PROVIDE COMPLETE ENGINEER
 ANALYSIS SHOWING HOW THE PROPOSED SECOND FLOOR TERRACE
 ASSEMBLY WILL MEET THE TERRACE LOADS SPECIFIED ON SHEET
 S-2 (DEAD LOAD 100 LBS PSF AND LIVE LOAD 125 LBS PSF).
 SEC. 107.2.1.3 CITY AMENDMENTS.
  
 B) PROVIDE COMPLETE ENGINEERED TRUSS PACKAGE (2 COPIES)
 SHOWING THE TERRACE DESIGN LOADS SPECIFIED BY THE
 ENGINEER OF RECORD ON THE FLOOR FRAMING PLAN ON SHEET
 S-2 (100 LBS PSF DEAD LOAD AND 125 LBS PSF LIVE LOAD).
 SEC. 107.2.1.3 CITY AMENDMENTS.
 NOTE: PACKAGE TO BE REVIEWED BY THE ENGINEER OF RECORD
 PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 2- SHEET S-1:
 A) ENGINEER TO CLARIFY DESIGN SPECIFICATIONS NOTE #2.
 THESE CONSTRUCTION DOCUMENTS ARE FOR A SECOND FLOOR
 TERRACE. WHY IS THE STRUCTURE CONSIDERED "ENCLOSED
 STRUCTURE". SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 B) CONCRETE PAD SCHEDULE IS NOT CLEAR: (1) ENGINEER TO
 CLARIFY SIZE OF OF CONCRETE PADS P1 AND P2. PLEASE
 PROVIDE DETAIL SHOWING THE 44"W X 42"D AND 42"W X 42"D
 CONCRETE PADS. (2) CONCRETE PAD P1 SHOWN ON FOUNDATION
 PLAN DOESN'T'T MATCH SIZE SHOWN ON CONCRETE PAD
 SCHEDULE. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS.
  
 C) AREA CALCULATIONS ARE INCORRECT. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 D) ALTERATION LEVEL IS INCORRECT. SEE SEC. 401.4 AND
 SEC. 407 OF 2010 FBC-EXISTING BUILDING.
  
 E) ENGINEER TO CLARIFY THE WIND DESIGN LOADS. ENGINEER
 CALLS FOR 2 DIFFERENT WIND LOADS ON THE SAME SHEET.
 ENGINEER CALLS FOR 170 MPH ULTIMATE WIND LOAD AND 175
 MPH ULTIMATE WIND LOAD ON THE SAME SHEET. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- SHEET S-2:
 A) SPECIFY ALL CONNECTORS AT THE ENDS OF ALL LVL'S
 BEAMS SHOWN ON THE FLOOR FRAMING PLAN. SEC. R301.1 OF
 2010 FBC-RESIDENTIAL.
  
 B) PROVIDE COMPLETE SECTION DETAIL THRU (2)2X12 P.T.
 WOOD LEDGER SHOWN ON FLOOR FRAMING PLAN. SPECIFY HOW
 MUCH EMBEDMENT IS REQUIRED TO THE EXISTING STRUCTURE
 AND SPECIFY ANCHOR SPACING. PROVIDE ENGINEER ANALYSIS
 SHOWING THAT 3/4" DIA X 4"L A.B. IS ADEQUATE FOR THE
 SPECIFIED TERRACE LOADS. NOTE: EXISTING STRUCTURE IS
 CONCRETE BLOCK. VERIFY TYPE OF ANCHOR SPECIFIED. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 C) SECOND FLOOR LAYOUT: PROVIDE GUARDRAIL COMPLETE
 CONSTRUCTION DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE LIVE LOADS REQUIRED BY TABLE R301.5
 OF 2010 FBC-RESIDENTIAL.
  
 D) HEIGHT OF GUARDRAIL IS DIFFERENT IN ALL PLANS AND
 DETAILS ON THIS SHEET. COORDINATE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 E) STAIRS DETAILS: (1) SIZE OF TREAD DOESN'T COMPLY
 WITH SEC. R311.7.4.1 OF 2010 FBC-RESIDENTIAL. (2)
 NOSING DETAIL DOESN'T COMPLY WITH SEC. R311.7.4.3 OF
 2010 FBC-RESIDENTIAL. (3) WHERE IS SECTION "A" TAKEN
 AT?. SEC. 107.2.1 CITY AMENDMENTS. (4) SPECIFY BEAM.
 SEC. 107.2.1 CITY AMENDMENTS. (5)SPECIFY ALL
 CONNECTORS. SEC. 107.2.1 CITY AMENDMENTS. SPECIFY SIZE
 AND LOCATION OF HANDRAIL. SEC R311.7.7 FBC-RESIDENTIAL.
  
 F) KNEE WALL/STAIRS SECTION: (1) WHERE IS THIS SECTION
 TAKEN AT?. INFORMATION DOESN'T MATCH FLOOR FRAMING
 PLAN. SEC. 107.2.1 CITY AMENDMENTS. (2) PROVIDE
 COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR THE
 STAIRWAY CONSTRUCTION. IT'S NOT CLEAR IF THE STAIRWAY
 IS GOING TO-BE OPEN ON ONE SIDE?. SEC. 107.2.1 CITY
 AMENDMENTS. (3) PROVIDE COMPLETE FASTENING
 SPECIFICATIONS FOR THE INSTALLATION OF THE 1 X 6 WOOD
 DECKING AND 1 X 6 CYPRESS CEILING. SEC. R301 OF 2010
 FBC-RESIDENTIAL. (4) WHERE IS THE SCHLUTER-DITRA150 AND
 SELF ADHERING-BASE SHEET INSTALLED IF THERE IS NOT
 SUBSTRATE BELOW?. SEC. 107.2.1 CITY AMENDMENTS. (5)
 FOOTING SIZE DOESN' MATCH FOUNDATION PLAN. SEC. 107.2.1
 CITY AMENDMENTS. (6) PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE CONSTRUCTION AND INSTALLATION OF
 THE DECORATIVE WOOD LOUVER, INCLUDING LOCATION OF
 PROPOSED LOUVER. SEC. R301. (7) PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR THE INSTALLATION OF
 "STUCCO CROWN MOLDING" AS SHOWN. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 G) POST COLUMN CONNECTION DETAIL: (1) PROVIDE
 MANUFACTURER SPECS FOR POST AND BEAM CONNECTORS
 SPECIFIED TO VERIFY COMPLIANCE WITH-THE PROPOSED
 INSTALLATION. NOTE: PRODUCT APPROVAL IS ALSO REQUIRED
 FOR EACH STRUCTURAL CONNECTOR. DCA RULE 9N-3. (2) POST
 SIZE DOESN'T MATCH SIZE SHOWN ON 2ND FLOOR LAYOUT. SEC.
 107.2.1 CITY AMENDMENTS.
  
 H) GUARDRAIL SECTION REFERENCED ON THE 2ND FLOOR LAYOUT
 AND KNEE WALL SECTION IS INCORRECT. SEE THE 2010
 FBC-RESIDENTIAL CODE FOR CORRECT REFERENCE AND REVISE
 AS REQUIRED.
  
 4-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR :
 A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL
 FRAMING PLANS AND DETAILS. PROVIDE FLORIDA PRODUCT
 APPROVAL COVER PAGE OR ENGINEER TO LIST FLORIDA PRODUCT
 APPROVAL NEXT TO THE SPECIFIED CONNECTOR.
  
 5- ENGINEER IS USING OLD SEAL. NEED TO USE CURRENT SEAL
 WITH THE WORDING "LICENSE" NOT "CERTIFICATE". SEC.
 61G15-23.001. F.A.C.
  
 6- IT'S NOT CLEAR WHY SUBMITTING PRODUCT APPROVALS FOR
 SINGLE HUNG WINDOWS, WINDOW MULLIONS. THE PLANS WERE
 REVISED AND THEY DON'T SHOW ANY SCOPE OF WORK OF NEW
 WINDOWS OR WINDOW REPLACEMENT. IF THERE IS GOING TO BE
 WINDOW REPLACEMENT, THEN REVISE PLANS AS REQUIRED
 SHOWING AREAS OF WORK. SPECIFY SIZE SIZE AND TYPE OF
 EXISTING WINDOWS AND PROPOSED WINDOWS. SEC. 604 OF 2010
 FBC-EXISTING BUILDING. REVISE VALUATION DECLARED IN THE
 PERMIT APPLICATION ACCORDINGLY.
  
 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. PROVIDE COPY OF SIGNED CONTRACT.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-10-02 Cont ID  
Sent By tklarge Date 2014-10-02 Time 09:31 Rev Time 0.00
Received By jgomez Date 2014-10-02 Time 09:31 Sent To  
Notes
2014-10-02 09:54:12RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) DOOR AT NEW STORAGE AREA AS SHOWN ON PLANS.
  
 B) NEW DECK HOLLOW CORE PANELS.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 3- SHEET A-5.1: PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE INSTALLATION OF STEEL BEAM B-1
 AT THE BEARING POINTS AND HOW ARE THE DECKING HOLLOW
 CORE PANELS ATTACHED TO THE BEAM. SEC. R301 OF 2010
 FBC-RESIDENTIAL.
  
 4- NEW HOLLOW CORE DECK PLAN ON SHEET A-5.1 CALLS FOR
 6" THICK HOLLOW CORE PANELS, WHILE WALL SECTIONS ON
 SHEET A-5.4 AND SHEET A-5.5 CALL FOR 8" THICK HOLLOW
 CORE PANELS. REVISE/CLARIFY AS REQUIRED TO MATCH AND
 COORDINATE WITH PRODUCT APPROVAL SUBMITTED. SEC.
 107.2.1 CITY AMENDMENTS TO FBC.
  
 5- PROVIDE COMPLETE INFORMATION FOR THE REQUIRED
 HANDRAIL AT STAIRWAY LEADING TO THE SECOND FLOOR DECK
 AS REQUIRED BY SEC. R311.7.7 OF 2010 FBC-RESIDENTIAL.
  
 6- PROVIDE COMPLETE INFORMATION FOR THE SECOND FLOOR
 DECK GUARDRAILS TO SHOW COMPLIANCE WITH THE DESIGN
 LOADS REQUIRED BY TABLE R301.5 AND THE REQUIREMENTS OF
 SEC. R312 OF 2010 FBC-RESIDENTIAL. ALSO, PROVIDE
 COMPLETE DETAILS AND SPECIFICATIONS FOR THE SOLID
 GUARDRAIL AS SHOWN ON ELEVATIONS.
  
 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. REVISE VALUATION TO INCLUDE ALL THE
 PAVERS AND STONE VENEER WORK SHOWN ON PLANS, PLUS THE
 ARCHITECT'S FEES.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REMOVE AND REPLACE ALL REVISED SHEETS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE DEPARTMENT
 (561)805-6712
 [email protected]
2014-09-24 11:44:53I MISTAKENLY PLACED MY NAME IN THE REVIEWER COLUMN FOR
 BUILDING. THIS PLAN NEEDS A STRUCTURAL PLAN REVIEW.TKL

Review Stop E ELECTRICAL
Rev No 5 Status N Date 2015-10-20 Cont ID  
Sent By jgomez Date 2015-10-20 Time 14:03 Rev Time 0.00
Received By jgomez Date   Time   Sent To  
Notes
2015-10-20 14:04:03NO ELECTRICAL WORK SHOWN. NO REVIEW REQUIRED.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2015-06-12 Cont ID  
Sent By rmcdouga Date 2015-06-12 Time 09:34 Rev Time 0.00
Received By rmcdouga Date 2015-06-12 Time 09:34 Sent To  
Notes
2015-06-12 09:36:53PLAN
 REVIEW COMMENTS
  
 4TH REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO COMPLETE SETS OF ELECTRICAL PLANS
 ADDRESSING THE COMMENTS FROM THE PREVIOUS REVIEWS.
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2015-05-18 Cont ID  
Sent By McDougal Date 2015-05-18 Time 17:47 Rev Time 0.00
Received By rmcdouga Date 2015-05-18 Time 17:47 Sent To  
Notes
2015-05-18 17:48:54PLAN REVIEW COMMENTS
  
 3RD REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PREVIOUS COMMENTS WERE NOT ADDRESSED. SEE COMMENTS
 FROM FIRST REVIEW. FBC107.2.1
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-04-16 Cont ID  
Sent By rmcdouga Date 2015-04-16 Time 13:54 Rev Time 0.00
Received By rmcdouga Date 2015-04-16 Time 13:54 Sent To  
Notes
2015-04-16 13:59:56PLAN REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PREVIOUS COMMENTS WERE NOT ADDRESSED. SEE COMMENTS
 FROM FIRST REVIEW. FBC107.2.1
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-10-09 Cont ID  
Sent By rmcdouga Date 2014-10-09 Time 07:38 Rev Time 0.00
Received By rmcdouga Date 2014-10-09 Time 06:58 Sent To  
Notes
2014-10-09 07:38:50PLAN REVIEW COMMENTS
  
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 ELECTRICAL
  
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NEC 220.40 - SUBMIT ELECTRICAL LOAD CALCULATIONS.
  
 2) FBC 107.3.5.3 - SUBMIT A PANEL SCHEDULE.
  
 3) FBC-R 315.1 - PROVIDE CARBON MONOXIDE ALARMS WITHIN
 10 FEET OF EACH SLEEPING ROOM.
  
 4) FBC- 107.3.5.3 - PROVIDE SMOKE ALARMS PURSUANT TO
 FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. SMOKE
 ALARMS ARE ALSO REQUIRED ON EACH ADDITIONAL STORY OF
 THE DWELLING.
 R314.3 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
 BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL
 SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR
 DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN
 INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE
 ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR
 THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL
 IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL.
 WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE
 INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM
 DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT
 THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE
 ALARMS IN THE INDIVIDUAL UNIT.
  
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2015-05-15 Cont ID  
Sent By jgomez Date 2015-05-15 Time 11:02 Rev Time 0.00
Received By jgomez Date 2015-05-15 Time 11:02 Sent To  
Notes
2015-05-15 11:03:02NO GAS WORK SHOWN ON PLANS. JG.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2015-04-12 Cont ID  
Sent By tklarge Date 2015-04-12 Time 10:54 Rev Time 0.00
Received By tklarge Date 2015-04-12 Time 08:53 Sent To  
Notes
2015-04-12 09:05:131) SIZE THE SECTION OF THE GAS PIPING DOWNSTREAM OF THE
 BBQ GRILL.
 2) THE NEW SHEET P2.0 APPEARS TO SHOW PE PIPING UNDER A
 SLAB. PE PIPING CAN ONLY BE USED OUTDOORS UNDERGROUND
 PER THE 2010 FBCR SEC.G2415.15.1.
 3) SUBMIT MANUF. SPECIFICATIONS FOR ALL NEW GAS
 APPLIANCES. ALL APPLIANCES SHALL BE LISTED AND LABELED.
 G2404.3.
 4) THERE IS ONLY ONE SET OF REVISED PLANS IN THE
 FOLDER.SUBMIT TWO SETS OF PLANS. WPB AMEND. TO 2010 FBC
 SEC. 107.1.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2014-09-24 Cont ID  
Sent By tklarge Date 2014-09-24 Time 11:53 Rev Time 0.00
Received By tklarge Date 2014-09-24 Time 11:53 Sent To  
Notes
2014-09-24 11:54:38WPB AMEND. TO 2010 FBC SEC.107.2.1.
 1) INDICATE ON THE PLAN IF THE RANGE IN THE KITCHEN IS
 GAS OR ELECTRIC AND IF IT IS EXISTING TO REMAIN, NEW,
 OR EXISTING TO BE REPLACED.
 2) INDICATE ON THE PLAN IF THE WASHER & DRYER ARE
 EXISTING TO REMAIN, NEW, OR EXISTING TO BE REPLACED.
 INDICATE ON THE PLAN IF THE DRYER IS ELECTRIC OR GAS.
 3) A YELLOW TRACER WIRE SHALL BE INSTALLED ADJACENT TO
 UNDERGROUND NONMETALLIC PIPING. INSTALLATION SHALL
 COMPLY W/2010FGC SEC.404.15.3, & FBCR, SEC. G2415.15.3.
 4) THE MAXIMUM ALLOWED BTU'S ON 1 1/2 " PE PIPE IN
 ACCORDANCE WITH GAS TABLE 402.4 (19 ) AND 2010 FBCR
 TABLE G2413.4 ( 7 ) AT 60 FT. IS 721,000 BTU'S. THE BTU
 LOAD SHOWN ON THE PLAN IS 750,000 BTU'S. THEREFORE THE
 GAS SYSTEM AS DESIGNED IS UNDERSIZED INCLUDING THE 3/4"
 LINES.
 5) SHOW THE LENGTH OF EACH SECTION OF THE SCH.40 STEEL
 PIPE.
 6) MANUFACTURER'S SPECIFICATION SHEETS SHALL BE
 SUBMITTED FOR ALL GAS APPLIANCES AT THE TIME OF PERMIT
 APPLICATION SUBMITTAL FOR THE GAS PERMIT.ALL EQUIPMENT
 SHALL BE LISTED AND LABELED PER FGC SEC.301.3 & 2010
 FBCR SEC. G2404.3
 7) GAS INSTALLATION SHALL BE UNDER A SEPARATE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2015-10-20 Cont ID  
Sent By jgomez Date 2015-10-20 Time 14:04 Rev Time 0.00
Received By jgomez Date 2015-09-30 Time 11:05 Sent To  
Notes
2015-09-30 11:06:10R08

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-08-07 Time 17:42 Rev Time 0.00
Received By skennedy Date 2015-07-14 Time 16:11 Sent To  
Notes
2015-07-14 16:11:14GIVEN TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-06-13 Cont ID  
Sent By jgomez Date 2015-06-13 Time 13:20 Rev Time 0.00
Received By jgomez Date 2015-05-27 Time 18:02 Sent To  
Notes
2015-05-27 18:03:21RE-SUBMITTAL SENT TO JULIO GOMEZ FOR BUILDING REVIEW.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-27 Cont ID  
Sent By jgomez Date 2015-05-18 Time 17:57 Rev Time 0.00
Received By jgomez Date 2015-04-27 Time 17:56 Sent To  
Notes
2015-05-27 17:58:07LAST REVIEW DONE BY ELECTRICAL REVIEWER ON 5/18/15. JG

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-16 Cont ID  
Sent By rmcdouga Date 2015-04-16 Time 13:55 Rev Time 0.00
Received By rmcdouga Date 2015-03-17 Time 14:47 Sent To  
Notes
2015-03-18 11:25:00R27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-09 Cont ID  
Sent By rmcdouga Date 2014-10-09 Time 07:39 Rev Time 0.00
Received By rmcdouga Date 2014-09-08 Time 13:30 Sent To  
Notes
2014-09-09 13:30:37SENT TO R5 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2015-04-14 Cont ID  
Sent By gomez Date 2015-04-14 Time 09:00 Rev Time 0.00
Received By jgomez Date 2015-04-14 Time 09:00 Sent To  
Notes
2015-04-14 09:01:05NO REQUIRED. NO NEW LIVING AREA. ADDITION IS FOR
 COVERED PATIO AND SECOND FLOOR DECK. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-10-02 Cont ID  
Sent By jgomez Date 2014-10-02 Time 11:51 Rev Time 0.00
Received By jgomez Date 2014-10-02 Time 11:51 Sent To  
Notes
2014-10-02 11:53:09NO REQUIRED. NO NEW LIVING AREA. ADDITION IS FOR
 COVERED PATIO AND SECOND FLOOR DECK. JG.

Review Stop P PLUMBING
Rev No 3 Status N Date 2015-05-15 Cont ID  
Sent By TKLarge Date 2015-05-15 Time 11:03 Rev Time 0.00
Received By jgomez Date 2015-05-15 Time 11:03 Sent To  
Notes
2015-05-15 11:04:08NO PLUMBING WORK SHOWN ON PLANS., JG.

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-04-12 Cont ID  
Sent By tklarge Date 2015-04-12 Time 10:54 Rev Time 0.00
Received By tklarge Date 2015-04-12 Time 08:48 Sent To  
Notes
2015-04-12 08:53:121) ONLY ONE SET OF REVISED PLANS HAVE BEEN SUBMITTED .
 TWO SETS SHALL BE SUBMITTED. WPB AMEND. TO 2010 FBC
 SEC.107.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-09-24 Cont ID  
Sent By tklarge Date 2014-09-24 Time 11:40 Rev Time 0.00
Received By tklarge Date 2014-09-24 Time 05:36 Sent To  
Notes
2014-09-24 11:02:31WPB AMEND. TO 2010 FBC SEC.107.2.1.
 1) INDICATE ON THE PLAN IF THE RANGE IN THE KITCHEN IS
 GAS OR ELECTRIC AND IF IT IS EXISTING TO REMAIN, NEW,
 OR EXISTING TO BE REPLACED.
 2) INDICATE ON THE PLAN IF THE WASHER & DRYER ARE
 EXISTING TO REMAIN, NEW, OR EXISTING TO BE REPLACED.
 INDICATE ON THE PLAN IF THE DRYER IS ELECTRIC OR GAS.
 3) A YELLOW TRACER WIRE SHALL BE INSTALLED ADJACENT TO
 UNDERGROUND NONMETALLIC PIPING. INSTALLATION SHALL
 COMPLY W/2010FGC SEC.404.15.3, & FBCR, SEC. G2415.15.3.
 4) THE MAXIMUM ALLOWED BTU'S ON 1 1/2 " PE PIPE IN
 ACCORDANCE WITH GAS TABLE 402.4 (19 ) AND 2010 FBCR
 TABLE G2413.4 ( 7 ) AT 60 FT. IS 721,000 BTU'S. THE BTU
 LOAD SHOWN ON THE PLAN IS 750,000 BTU'S. THEREFORE THE
 GAS SYSTEM AS DESIGNED IS UNDERSIZED INCLUDING THE 3/4"
 LINES.
 5) SHOW THE LENGTH OF EACH SECTION OF THE SCH.40 STEEL
 PIPE.
 6) MANUFACTURER'S SPECIFICATION SHEETS SHALL BE
 SUBMITTED FOR ALL GAS APPLIANCES AT THE TIME OF PERMIT
 APPLICATION SUBMITTAL FOR THE GAS PERMIT.ALL EQUIPMENT
 SHALL BE LISTED AND LABELED PER FGC SEC.301.3 & 2010
 FBCR SEC. G2404.3
 7) GAS INSTALLATION SHALL BE UNDER A SEPARATE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-10-02 Cont ID  
Sent By sgraham Date 2015-10-02 Time 11:48 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-03-20 Cont ID  
Sent By sgraham Date 2015-03-20 Time 13:03 Rev Time 0.00
Received By sgraham Date 2015-03-20 Time 13:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By sgraham Date 2014-09-11 Time   Rev Time  
Received By   Date 2014-09-11 Time   Sent To  
Notes
2014-09-11 15:49:209/11/14 ZONING FAILED
  
 1. SUBMIT 2-COPIES OF AN UP TO DATE SURVEY.
2014-09-11 15:11:559/11/14