Plan Review Details - Permit 14090187
Plan Review Stops For Permit 14090187 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-17 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-17 |
Time |
07:29 |
Sent To |
|
|
Notes |
2014-09-17 07:32:53 | DATE: 9/17/2014 | | PROJECT: AVACODO GRILL | | PERMIT#: 14060973 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW ON REVISION #14090187 | | ACTION: PROVISO | | | | THERE IS NO LOW VOLTAGE DATA CABLING SHOWN ON THE | | MASTER PERMIT SET. A SEPARATE PERMIT APPLICATION | | ACCOMPANIED BY MANUFACTURERS EQUIPMENT SUBMITTALS, AND | | SHOP DRAWINGS FOR ANY AND ALL OF THE FOLLOWING: POS | | SYSTEM, FIRE ALARM, SECURITY, CCTV, DATA/COM, NETWORK, | | STRUCTURED CABLING, AUDIO(SPEAKERS)/VIDEO, AND SIGNAGE. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-09-06 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-06 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-06 |
Time |
12:46 |
Sent To |
|
|
Notes |
2014-09-06 13:24:14 | DATE: 9/6/2014 | | PROJECT: AVACODO GRILL | | PERMIT#: 14060973 REVISION #14090187 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW ON REVISION #14090187 | | ACTION: DENIED | | | | 1) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. WPB AMENDMENTS | | TO FBC 107.2.1 THE PLAN IS NOT SIGNED BY THE DESIGNER | | OF RECORD. | | | | 2) THE SHEET NUMBER DOES NO COINCIDE WITH THE SHEET | | NUMBER ON THE PERMIT SET. THE SHEET #A5 ON THE PERMIT | | SET IS THE PLUMBING PLAN. THE ELECTRICAL PLAN IS ON | | SHEET #A4. REVISE THE SHEET NUMBER TO COINCIDE WITH THE | | APPROVED PERMIT SET. | | | | 3) THERE IS NO LOW VOLTAGE DATA CABLING SHOWN ON THE | | MASTER PERMIT SET. A SEPARATE PERMIT APPLICATION | | ACCOMPANIED BY MANUFACTURERS EQUIPMENT SUBMITTALS, AND | | SHOP DRAWINGS FOR ANY AND ALL OF THE FOLLOWING: POS | | SYSTEM, FIRE ALARM, SECURITY, CCTV, DATA/COM, NETWORK, | | STRUCTURED CABLING, AUDIO(SPEAKERS)/VIDEO, AND SIGNAGE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-17 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-17 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-16 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-06 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-06 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-05 |
Time |
17:19 |
Sent To |
|
|
Notes |
2014-09-05 17:19:48 | INCOMING SENT TO D. HAYES DESK. JW |
|
|
|