Plan Review Details - Permit 14090037
Plan Review Stops For Permit 14090037
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-09-18 Cont ID  
Sent By jwitmer Date 2014-09-18 Time 08:13 Rev Time 0.00
Received By jwitmer Date 2014-09-18 Time 06:57 Sent To HIST
Notes
2014-09-18 08:13:50BUILDING PLAN REVIEW
 REVISION: 14090037
 PERMIT: 13030782
 ADD: 326 FERN ST
 CONT: STRATICON
 TEL: (561)436-4733
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. SEPT. 18/2014
 ACTION: DENIED
  
 1) COMPLIED. THRESHOLD BUILDING (3) SETS OF DOCUMENTS.
  
 2) THE HAND DRAWN SKETCH FOR UNIT # 12331 HAS A PARTIAL
 SHOP DRAWING STAMP, IT DOES NOT INDICATE IF APPROVED OR
 NOT.2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
  
 3) NOA # 11-1031.06 CGI WINDOWS SERIES 130 SENTENEL.
 SHEET 2 OF 6 HAS HIGHLIGHTED 60 X 60 INCH WINDOWS WITH
 GLASS TYPE "C" & "C1" WITH A +/- 48.8. THE VASD
 PRESSURES ZONE # 4 ARE =/- 50.1 AND FOR ZONE # 5 ARE
 +50.1 & -91.3. THE VASD PRESSURES ARE LOW FOR THIS
 WINDOW SIZE.2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
  
 4A) NOA # 12-0706.03 CGI DOOR SERIES "450" OUTSWING
 GLAZED W/WO SIDELITES. WINDOW NOA # 11-1031.06
 INDICATES HAND WRITTEN 1ST FLOOR ONLY SECTION OF
 STOREFRONT WITHIN 8.2 FT OF EDGE OF BUILDING (ZONE # 5)
 PRESSURES +50.1/ -91.3 VASD. NOTE THIS SHEET
 INDICATESTHE STANDARD HARDWARE IS ONLY GOOD FOR +/-
 70.2. 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
  
 4B) NOA # 12-0706.03 CGI DOOR SERIES "450" OUTSWING
 GLAZED W/WO SIDELITES. SHEET 1.1 OF 7 INDICATES
 (HIGHLIGHTED BOTH 10A & 10AA DOOR HEIGHT OF 96 3/4 IN.
 THE PRESSURES FOR 10A ARE +/- 90.0. LOW REQUIRED 91.3
 VASD. 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
  
 4C) NOA # 12-0706.03 CGI DOOR SERIES "450" OUTSWING
 GLAZED W/WO SIDELITES. SHEET 7 OF 7 MULLION ANCHORS NOT
 PROVIDED (HIGHLIGHTED) ON
 THE PLANS.
  
 5) NOA # 12-0203.13 CGI WINDOW & DOOR, CLIPPED EXTRUDED
 ALUMINUM MULLION. MULLION SIZES, RE-INFORCED OR NOT,
 NOR ANCHORS ARE IDENTIFIED NOR THE PRESSURES. 2010
 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING.
  
 NOTE THE 1ST HISTORIC REVIEW NOT SHOWN AS REVIEWED WILL
 NEED TO SEND THE 2ND PACKAGE TO HISTORICS FOR REVIEW.
 NOTE THE NOA # 11-1031.06 CGI WINDOWS SERIES 130
 SENTENEL SHOWS THE MUTTINS AS A OPTION, THIS MAY BE A
 ISSUE WITH HISTORICS, TO KEEP THE HISTORICAL FEATURES
 OF THE BUILDING, HISTORIC REVIEW IS REQUIRED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-03 Cont ID  
Sent By jwitmer Date 2014-09-03 Time 08:41 Rev Time 0.00
Received By jwitmer Date 2014-09-03 Time 07:48 Sent To HIST
Notes
2014-09-03 08:41:49BUILDING PLAN REVIEW
 REVISION: 14090037
 PERMIT: 13030782
 ADD: 326 FERN ST
 CONT: STRATICON
 TEL: (561)436-4733
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED SEPT. 03/2014
 ACTION: DENIED
  
 1) THIS IS A THRESHOLD BUILDING REQUIRING (3) OF ALL
 STRUCTURAL DOCUMENTS & COMPONENTS AND CLADDING (PRODUCT
 APPROVALS) . 107.3.1.
  
 2) 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN
 APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 PLEASE CIRCLE THE SIZE OF THE WINDOW, GLASS TYPE,
 CIRCLE NOT HIGHLIGHT (HIGHLIGHTING DOESN'T SHOW UP
 UNDER THE SCANNING FOR RECORD RETENSION)
 PRESSURES AND ANCHOR METHOD AS WELL AS MULLIONS BOTH
 THE VERTICAL AND HORIZONTAL MULLIONS ARE HIGHLIGHTED,
 PLEASE CICLE THE WINDOW SIZE AND APPROPRIATE AMOUNT OF
 ANCHORS FOR THE INSTALATION.
  
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2014-09-24 Cont ID  
Sent By fmittner Date 2014-09-24 Time 16:39 Rev Time 0.00
Received By fmittner Date 2014-09-24 Time 16:39 Sent To Z
Notes
2014-10-03 14:05:24PER 10/1/14 E-MAIL CLARIIFIED BOTH NEW AND
 REPLACEMENT.....APPROVED
2014-09-24 16:41:03SENT TO ANA MARIA FOR DMP REVIEW.
2014-09-24 16:40:33FRIEDERIKE MITTNER CONFIRMED WITH DAVINA (ARCHITECT)
 THAT NEW WINDOWS ARE ONLY FOR LOCATIONS WHERE HSITORIC
 WINDOW HAS BEEN REMOVED. THE NEW WINDOWS WILL MATCH THE
 EXISTING IN DESIGN AND MUNTIN CONFIGURATION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-09-24 Cont ID  
Sent By fmittner Date 2014-09-24 Time 16:38 Rev Time 0.00
Received By fmittner Date 2014-09-24 Time 16:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-25 Cont ID  
Sent By aaponte Date 2014-09-25 Time 08:46 Rev Time 0.00
Received By aaponte Date 2014-09-09 Time 15:47 Sent To  
Notes
2014-09-25 08:46:43FAILED . FILED UNDER "S" . APPLICANT CONTACTED.
2014-09-22 16:59:599/22 FOUND IN MISC 1 BOX
 ROUTED TO ZONING BOX
  
2014-09-09 15:51:53TO JW'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By dhayes Date 2014-09-02 Time 07:25 Sent To B
Notes
2014-09-03 07:26:22TO J.W'S DESK.

Review Stop Z ZONING
Rev No 1 Status P Date 2014-09-25 Cont ID  
Sent By aaponte Date 2014-09-25 Time 08:45 Rev Time 0.00
Received By aaponte Date 2014-09-25 Time 08:45 Sent To  
Notes
***NONE***