Plan Review Stops For Permit 14081199 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
N |
Date |
2015-04-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-04-30 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-04-30 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2014-11-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-18 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-18 |
Time |
08:12 |
Sent To |
|
|
Notes |
2014-11-18 08:16:59 | SEE PREVIOUS REVIEWS: AT THIS POINT, WE ARE DOWN TO | | SHUTTER INSTALLATION SCHEDULE, WINDOW AND DOOR PRODUCT | | APPROVALS. ADDITIONALLY, THIS WORK (CARPORT ENCLOSURE) | | IS COMPLETE WITH NO INSPECTIONS, SO AN ENGINEERS | | CERTIFICATION LETTER IS REQUIRED FOR THIS WORK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2014-11-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-04 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-04 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-10 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-10 |
Time |
11:33 |
Sent To |
|
|
Notes |
2014-10-10 11:34:34 | SEE PREVIOUS COMMENTS, APPLICANT HAS CHECKED OUT A SET | | TO REGROUP WITH DESIGNER. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-09-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-14 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-14 |
Time |
14:35 |
Sent To |
|
|
Notes |
2014-09-14 14:40:02 | FBC 2010 3RD REVIEW: | | SEE COMMENTS BELOW FROM PREVIOUS REVIEWS: ALTHOUGH YOU | | HAVE NOW 2 FULL SIZE SETS, THE COMMENTS BELOW STILL | | APPLY. | | SEE THE COMMENTS ON PLUMBING AND ELECTRICAL REVIEW. | | | | FBC 2010, 2ND REVIEW: | | | | THE SUBMITTAL IS INSUFFICIENT IN TERMS OF SETS, FORMS, | | SUBMITTAL DOCUMENTS AND DEFINED SCOPE OF WORK. | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. | | | | NO SHUTTER INFOFRMATION HAS BEEN PROVIDED. | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | YOU HAVE SUBMITTED PHOTO COPIES OF AN OLD PLAN BEARING | | THE TITLE BLOCK OF THE ORIGINAL ENGINEER. IS THIS | | ENGINEER INVOLVED WITH THIS PROJECT? IF NOT, REMOVE THE | | INFOMATION OR INDICATE WHY THIS IS BEING PROVIDED. | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | THE SMALL SET OF PLANS IS NOT ACCEPTABLE. IT IS A | | REDUCED PHTO COPY. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD AS | | MAY BE APPLICABLE. | | THE PRODUCT INFORMATION IS STILL NOT PROVIDED.. | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-CHAPTER 16 OR UTILIZE THE | | SHUTTER INSTALLATION SCHEDULE FORM AVAILABLE AT | | WPB.ORG. | | THIS INFORMATION IS STILL NOT PROVIDED. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-09-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-10 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-10 |
Time |
09:01 |
Sent To |
|
|
Notes |
2014-09-10 10:31:48 | FBC 2010, 2ND REVIEW: | | | | THE SUBMITTAL IS INSUFFICIENT IN TERMS OF SETS, FORMS, | | SUBMITTAL DOCUMENTS AND DEFINED SCOPE OF WORK. | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. | | ONE SET IS A SMALL PHOTO COPY, NO SHUTTER INFOFRMATION | | HAS BEEN PROVIDED. | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | YOU HAVE SUBMITTED PHOTO COPIES OF AN OLD PLAN BEARING | | THE TITLE BLOCK OF THE ORIGINAL ENGINEER. IS THIS | | ENGINEER INVOLVED WITH THIS PROJECT, IF NOT, REMOVE THE | | INFOMATION OR INDICATE WHY THIS IS BEING PROVIDED. | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | THE SMALL SET OF PLANS IS NOT ACCEPTABLE. IT IS A | | REDUCED PHTO COPY. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD AS | | MAY BE APPLICABLE. | | THE PRODUCT INFORMATION IS STILL NOT PROVIDED.. | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-CHAPTER 16 OR UTILIZE THE | | SHUTTER INSTALLATION SCHEDULE FORM AVAILABLE AT | | WPB.ORG. | | THIS INFORMATION IS STILL NOT PROVIDED. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-09-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-02 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-02 |
Time |
11:06 |
Sent To |
|
|
Notes |
2014-09-02 11:32:24 | FBC 2010, 1ST REVIEW: | | | | THE SUBMITTAL IS INSUFFICIENT IN TERMS OF SETS, FORMS, | | SUBMITTAL DOCUMENTS AND DEFINED SCOPE OF WORK. | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD AS | | MAY BE APPLICABLE. | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-CHAPTER 16 OR UTILIZE THE | | SHUTTER INSTALLATION SCHEDULE FORM AVAILABLE AT | | WPB.ORG. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2014-11-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-17 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-17 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-05 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-05 |
Time |
11:28 |
Sent To |
|
|
Notes |
2014-11-05 11:29:30 | 4TH REVIEW: FBC 2010 | | | | SEE PREVIOUS COMMENTS AND MOST RECENT COMMENTS FOR | | BUILDING PLAN REVIEW. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-10 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-10 |
Time |
11:34 |
Sent To |
|
|
Notes |
2014-10-10 11:34:57 | SEE PREVIOUS COMMENTS, APPLICANT HAS CHECKED OUT A SET | | TO REGROUP WITH DESIGNER. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2014-09-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-14 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-14 |
Time |
13:46 |
Sent To |
|
|
Notes |
2014-09-14 14:21:52 | 2ND REVIEW: FBC 2010 | | | | SEE IST REVIEW COMMENS BELOW, ADDITIONALLY PLEASE | | PROVIDE A CLEAR DESIGN AND SCOPE OF WORK, THE | | APPLICATION STATES "REPLACE EXISTING WIRE AND ELECTRIC | | BOX. "PANEL 125 AMP 24 LTS RELOCATE." THIS IS UNCLEAR | | AS THE INCLUDED PLANS DO NOT INDICATE THIS SCOPE OF | | WORK. PLEASE PROVIDE CLEAR PLANS AND SCOPE OF WORK. | | | | 1ST REVIEW: FBC 2010 | | | | THE ELECTRICAL SUBMITTAL IS UNCLEAR. SEE BUILDING | | REVIEW COMMENTS. THE ELECTRICAL DESCRIPTION ON THE | | ATTACHED SUB ELECTRICAL APPLICATION AND THE SEPARATE | | ELECTRICAL PLAN ATTTACHED THERETO ARE NOT COMPATABLE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-09-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-10 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-10 |
Time |
10:26 |
Sent To |
|
|
Notes |
2014-09-10 10:42:29 | 1ST REVIEW: FBC 2010 | | | | THE ELECTRICAL SUBMITTAL IS UNCLEAR. SEE BUILDING | | REVIEW COMMENTS. THE ELECTRICAL DESCRIPTION ON THE | | ATTACHED SUB ELECTRICAL APPLICATION AND THE SEPARATE | | ELECTRICAL PLAN ATTTACHED THERETO ARE NOT COMPATABLE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2015-04-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-04-30 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-04-30 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2014-11-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-18 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-13 |
Time |
12:51 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-05 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-14 |
Time |
14:56 |
Sent To |
|
|
Notes |
2014-11-05 13:03:03 | 5TH REVIEW: FBC 2010 | | | | PLEASE SEE PREVIOUS REVIEWS. | | | | ADDITIONAL COMMENTS: | | | | FBC 107 PROVIDE A SITE PLAN. DEMONSTRATE SETBACKS AND | | FIRE SEPARATION. | | | | ALTHOUGH IT IS UNCLEAR FROM THE APPLICATION, THE INTENT | | OF THIS SUBMITTAL IS TO LEGALIZE AN ACCESSORY BUILDING | | THAT WAS APPARENTLY CONSTRUCTED WITHOUT PERMITS. THE | | BUILDING IN QUESTION IS APPROXIMATELY 18.5 X 18.75 FEET | | SQUARE AND IS DIPICTED AS EXISTING ON SHEET 2 OF | | DRAWINGS SUBMITTED ON OCTOBER 10. A SEARCH OF PERMIT | | RECORDS INDICATES SUCH A BUILDING DID NOT EXIST | | ACCORDING TO A SURVEY ON FILE DATED 1998 AND THAT THERE | | IS NO PERMIT RECORD FOR CONSTRUCTING THE BUILDING ANY | | TIME ON FILE. THERE IS NO ASSURANCE THAT THE STRUCTURE | | MEETS ZONING SETBACKS OR REQUIRED SEPARATION FROM OTHER | | STRUCTURES. THE APPLICATION IS ON HOLD BASED ON | | DISCUSSION WITH THE ENGINEER OF RECORD, RIZA ALTAN. | | | | RE SUBMITTAL IS ANTICIPATED TO BE FOR DEMOLITION OF | | THIS STRUCTURE AND FOR IMPROVEMENT OF THE ITEMS SHOWN | | ON SHEET 1 OF THE DRAWINGS. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-10 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-18 |
Time |
18:51 |
Sent To |
|
|
Notes |
2014-09-18 18:52:07 | SENT TO S KENNEDY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-09-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-14 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-10 |
Time |
11:46 |
Sent To |
|
|
Notes |
2014-09-11 11:47:05 | TO SAK DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-10 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-08 |
Time |
14:44 |
Sent To |
|
|
Notes |
2014-09-08 14:44:59 | RE-SUBMITTAL SENT TO STEVE KENNEDY'S DESK FOR REVIEW. | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-02 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-08-27 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2014-11-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-17 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-17 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-05 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-11-05 |
Time |
10:12 |
Sent To |
|
|
Notes |
2014-11-05 10:13:19 | 3RD REVIEW: FBC 2010 | | | | SEE COMMENTS FROM PREVIOUS REVIEWS. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-10-10 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-10-10 |
Time |
11:35 |
Sent To |
|
|
Notes |
2014-10-10 11:35:20 | SEE PREVIOUS COMMENTS, APPLICANT HAS CHECKED OUT A SET | | TO REGROUP WITH DESIGNER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-09-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-14 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-14 |
Time |
14:22 |
Sent To |
|
|
Notes |
2014-09-14 14:34:59 | 1ST REVIEW: FBC 2010 | | | | A PLUMBING PLAN HAS BEEN ADDED TO THE SUBMITTAL. THE | | DESCRIPTION ON THE PLUMBING PERMIT APPLICATION IS NOT | | CONSISTENT WITH PLANS SUBMITTED. IT SEEMS THE INTENT OF | | THE APPLICATION IS TO DEMOLISH SOME PART OF THE | | ACCESSORY BUILDING, BUT THERE IS NO PLAN INDICATING SO. | | ADDITIONALLY, IT APPEARS THE INTENT IS TO REMODEL THE | | KITCHEN IN THE PRIMARY STRUCTURE. THE PLUMBNG PLAN | | SUBMITTED FOR THIS PART OF THE WORK IS ACCETABLE IN | | DETAIL, BUT NEEDS TO BE SIGNED THE THE PLUMBER IF HE IS | | TAKING RESPONSIBILITY FOR THAT PART OF THE DESIGN PER | | THE SECTION BELOW: | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-11-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-11-18 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-11-17 |
Time |
16:08 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2014-11-05 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-11-05 |
Time |
08:59 |
Sent To |
B |
|
Notes |
2014-11-05 09:00:19 | 11/5/14 ZONING FAILED | | | | 1. PROVIDE TWO UP TO DATE SURVEYS SHOWING THE LOCATION | | OF THE BUILDING. |
|
|