2014-11-20 09:32:15 | BUILDING PLAN REVIEW |
| PERMIT: 14081171 |
| ADD: 739 43RD ST. |
| CONT: T. H. MOTTLEY |
| TEL: (561)502-1986 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 4TH REVIEW |
| DATE: THURS. NOV. 20/2014 |
| ACTION: DENIED |
| |
| NOTICE:!!!!!!!!!! |
| CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A |
| LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE |
| FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE |
| TIMES FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. |
| |
| 1) IF THE CONTRACTOR IS TAKING RESPONSIBILITY FOR THE |
| DESIGN AND DRAFTING OF THE SUBMITTED PLANS, PLEASE |
| PRINT NAME, SIGN NAME AND LICENSE NUMBER ON THE PLANS. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS. |
| |
| 2) REPEAT COMMENT, REVISE PLANS TO STATE WHAT SIZE OF |
| THE EXISTING WINDOW, TYPE OF WINDOW, (AWNING, CASEMENT, |
| DOUBLE HUNG OR SINGLE HUNG WINDOW. |
| NOTE THESE DIMENSIONS ARE NOT ONLY REQUIRED TO |
| DETERMINE EGRESS REQUIREMENTS FOR SLEEPING ROOMS BUT |
| ALSO FOR THE SHUTTER SCHEDULE. |
| FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. / |
| FBC-RFBC-R R308.3.1 IMPACT TEST. |
| |
| 3) REPEAT COMMENT. THE QUESTION HAS BEEN ASKED FOR THE |
| EGRESS WINDOWS PROVIDED DIMENSIONS OF 36 X63 IN. PLEASE |
| PROVIDE WHAT THE CLEAR OPENING OR VENT SIZE IS OF THE |
| EGRESS WINDOWS, THIS HAS NOT BEEN PROVIDED, SHOW |
| COMPLIANCE WITH 2010 FBC-R R310.1.1 MINIMUM OPENING |
| AREA. |
| GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR |
| OPENING OF 5 SQUARE FEET (0.465 M2). |
| R310.1.2 MINIMUM OPENING HEIGHT. |
| THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES |
| (610 MM). |
| R310.1.3 MINIMUM OPENING WIDTH. |
| THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES |
| (508 MM). |
| 2010 FBC-EXISTING BLDG. CODE 604.1 GENERAL. |
| MEANS OF EGRESS FOR BUILDINGS UNDERGOING ALTERATION |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 601.1 AND |
| THE SCOPING PROVISIONS OF CHAPTER 1 WHERE APPLICABLE. |
| EXCEPTION: DOOR AND WINDOW DIMENSIONS. IN RESIDENTIAL |
| DWELLINGS AND DWELLING UNITS, A MAXIMUM OF 5 PERCENT |
| REDUCTION IN THE CLEAR OPENING DIMENSIONS OF |
| REPLACEMENT DOORS AND WINDOWS SHALL BE ALLOWED. |
| |
| 4) REPEAT COMMENT; SHUTTER SCHEDULE, THE SHUTTER |
| SCHEDULE SUBMITTED IS ONLY FOR THE SLEEPING ROOM |
| WINDOWS. ALL WINDOWS BEING REPLACED WILL REQUIRE |
| STORM SHUTTERS SINCE THE PRODUCT APPROVALS SUBMITTED |
| ARE NON- IMPACT REATED GLASS. FBC-RFBC-R R308.3.1 |
| IMPACT TEST. |
| PROVIDE STORM PANEL INFORMATION WITH INSTALLATION |
| SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND |
| MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC |
| 1609.1.4. |
| |
| FL BLD CODE 2010 SECTION 107.2.4, 1609.1.4, 1715.2 & |
| EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE |
| INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE |
| SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE |
| PLAN REVIEW AND PERMIT ISSUANCE. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |