Plan Review Details - Permit 14081170
Plan Review Stops For Permit 14081170 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-02-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-02-26 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-26 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-02-24 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-24 |
Time |
07:18 |
Sent To |
|
|
Notes |
2015-02-24 07:19:57 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | RESPONSE LETTER STATES THAT THE FORM WAS ATTACHED, BUT | | IT WAS NOT SUBMITTED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-01-20 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-01-20 |
Time |
09:18 |
Sent To |
|
|
Notes |
2015-01-20 09:19:02 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | 2. THE STORM PANEL NOA NUMBER ON THE PLAN IS NOT | | CONSISTENT WITH THE NUMBER OF THE PRODUCT APPROVAL | | SUBMITTED, FBC 107. PLEASE CORRELATE. | | | | 3. PLAN DOES NOT INDICATE WHERE THE INFILL DETAIL 2-A1 | | WILL BE INSTALLED, FBC 107. | | | | 4. BOND BREAK REQUIRED, REVISE INFILL DETAIL 2-A1, FBC | | 2010 RESIDENTIAL 703.6.3. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
Sent By |
mmanhong |
Date |
2014-09-09 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-09 |
Time |
16:54 |
Sent To |
|
|
Notes |
2015-01-20 09:19:56 | 1/20 CHANGED FROM "P" TO "F" (TO PREVENT PERMIT FROM | | BEING ISSUED INADVERTENTLY) AS 2ND REVIEW FAILED | 2014-09-09 16:54:31 | OKAY TO ISSUE PER SAMANTHA HILL ON 09/08/2014 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2015-02-24 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-10 |
Time |
10:49 |
Sent To |
B |
|
Notes |
2015-02-11 10:50:43 | TO S.HILL'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-01-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-01-20 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-01-13 |
Time |
17:43 |
Sent To |
|
|
Notes |
2015-01-13 17:43:49 | UPDATED PACKAGE TO SHILL. PERMIT NEVER ISSUED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-02-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-01-20 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-18 |
Time |
07:23 |
Sent To |
|
|
Notes |
2014-09-19 07:24:11 | SENT TO S HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-09 |
|
|
Cont ID |
|
Sent By |
mmanhong |
Date |
2014-09-09 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
mmanhong |
Date |
2014-09-09 |
Time |
16:54 |
Sent To |
|
|
Notes |
2014-08-27 09:05:54 | ROUTED TO MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |