Plan Review Details - Permit 14081143
Plan Review Stops For Permit 14081143
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-10-17 Cont ID  
Sent By jwitmer Date 2014-10-17 Time 16:41 Rev Time 0.00
Received By jwitmer Date 2014-10-17 Time 14:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 11:56 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 09:45 Sent To  
Notes
2014-08-28 11:55:58BUILDING PLAN REVIEW
 PERMIT: 14081143
 ADD: 303 BANYAN BLVD
 CONT: IBIS BUILDING
 TEL: (561)318-3408
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUG. 28/2014
 ACTION: DENIED
  
 1) SHEET A1.1 VERSES THE STRUCTURAL SHEETS. THE PLANS
 ARE NOT CLEAR TO THE BACK 1/3RD OF THE TENANT SUITE IF
 THE CONCRETE FLOOR IS BEING REMOVED OR IS THE STEEL
 FRAMING BELOW BEING REPLACED? THERE IS NO NOTE ON THE
 A1.1 UNDER THE DEMO NOTES THIS FLOOR IS BEING REMOVED.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) SHEET A1.1 LIST THE COMMON PATH OF TRAVEL FROM THE
 BACK CORNER OF THE RESTROOM TO THE FRONT ENTRY 107 FT.
 THAT EXCEEDS THE COMMON PATH OF TRAVEL EXCEPTION # 1 OF
 1014.3 OF 100 FT. WOULDN'T THE COMMON PATH OF TRAVEL
 STOP AT THE REAR EXIT.
  
 3) OFFICE # 104 THE INSWING DOOR DOES NOT HAVE THE
 REQUIRED 18 INCHES LATCH SIDE OF DOOR. 2010
 FBC-ACCESSIBILITY CODE 404.2.4.1 AND TABLE 404.2.4.1.
  
 4A) A1.1 SHOWS A 2HR RATED STAIR ENCLOSURE, SHEET A.2.1
 SHOWS A WALL INFILL, WALL IDENTIFICATION TAG W3. PLEASE
 REVIEW SHEET A3.1 WALL TYPES. THE WRITTEN WORD DOES NOT
 LINE UP WITH THE DETAILS, NOT SURE WHICH DETAIL TIES TO
 WHICH WALL TYPE. DISCREPANCY IN PLANS. 107.2.1.3.
  
 4B) SHEET A3.1 WALL IDENTIFICATION TAGS, 2 WALL TYPES
 INDICATE A UL DESIN NUMBER, U419 & U465. NEITHER
 PROVIDE A DETAIL OF THESE ASSEMBLIES. NOTE U-419 CAN BE
 1-4 HOUR RATING, WHICH ARE YOU DESIGNING TOO?
  
 4C) SHEET A2.1, A3.1 AND S-1 DISCREPANCY IN PLANS. THE
 INFILL WALL OF THE 2 HR RATED EXIT ENCLOSRE ON THE
 SHEET S-1 INDICATES THE USE OF 8 INCH CMU. 107.2.1.3
 DISCREPANCY IN PLANS, ADDITIONAL INFORMATION IS
 REQUIRED.
  
 5) SHEET S-2 INDICATES TH USE OF 20 GAUGE STUDS, IN 20
 GAUGE STUDS THERE ARE (2) THICKNESSES, PLEASE SPECIFY,
 DRYWALL 30(MILS) AND STRUCTURAL 33(MILS)?
  
 6) SHEET A 2.1 & A4.1 BOTH INDICATE A NEW EXTERIOR
 DOOR, PLEASE PROVIDE COMPLIANCE WITH: 2010 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS
 & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
  
  
 7) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-10-16 Cont ID  
Sent By rlecky Date 2014-10-16 Time 12:44 Rev Time 0.00
Received By rlecky Date 2014-10-16 Time 12:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-09-11 Cont ID  
Sent By rlecky Date 2014-09-11 Time 11:29 Rev Time 0.00
Received By rlecky Date 2014-09-11 Time 11:18 Sent To  
Notes
2014-09-11 11:35:56 
 14081143
 303 BANYAN BLVD. #101
 INTERIOR RENOVATION
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 PROVIDE A LIGHTING DENSITY SUMMARY ON THE ELECTRIC PLAN
 WHICH SHOWS COMPLIANCE WITH THE FLORIDA BUILDING ENERGY
 CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.5;
 505.5.3; T. 505.5.3
  
 PROVIDE A PANEL SCHEDULE AND RISER PLAN FOR PANEL L1B.
 OC DEVICES MUST BE READILY ACCESSIBLE TO THE OCCUPANT.
 NEC 215.5, 240.24
  
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-08-29 Cont ID  
Sent By pleduc Date 2014-08-29 Time   Rev Time 0.00
Received By pleduc Date 2014-08-28 Time 15:11 Sent To  
Notes
2014-08-29 10:32:54THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-11-17 Cont ID  
Sent By hmoser Date 2014-11-17 Time 14:43 Rev Time 0.00
Received By hmoser Date 2014-11-12 Time 15:22 Sent To  
Notes
2014-11-12 15:24:10NEW MECHANICAL AND PLUMBING REVISED DRAWINGS SUBMITTED.
 SENT TO TIM LARGE FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-03 Cont ID  
Sent By skennedy Date 2014-11-03 Time 09:36 Rev Time 0.00
Received By skennedy Date 2014-10-14 Time 14:30 Sent To  
Notes
2014-10-15 14:30:36RE-SUBMITTAL SENT TO B4 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-22 Cont ID  
Sent By skennedy Date 2014-09-22 Time 11:48 Rev Time 0.00
Received By skennedy Date 2014-08-26 Time 16:54 Sent To  
Notes
2014-08-26 16:55:01B27
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-11-17 Cont ID  
Sent By hmoser Date 2014-11-17 Time 14:42 Rev Time 0.00
Received By hmoser Date 2014-11-17 Time 14:25 Sent To  
Notes
2014-11-12 15:19:51NEW SHEET M2.1 SUBMITTED. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-10-29 Cont ID  
Sent By hmoser Date 2014-10-29 Time 14:45 Rev Time 0.00
Received By hmoser Date 2014-10-28 Time 14:59 Sent To  
Notes
2014-10-29 14:45:05PASS PROVISO
 REFER TO SECTION 502.2.4.4 SHUTOFF DAMPER CONTROL
 2010 FLORIDA ENERGY CODE.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-09-22 Cont ID  
Sent By rbergsma Date 2014-09-22 Time   Rev Time 1.00
Received By rbergsma Date   Time   Sent To  
Notes
2014-09-22 11:16:47PLEASE CLARIFY M4.1
 THE AIR BALANCE / VENTILATION CALCS / FANN SCHEDULE
 SHOW THE TOILET ROOMS AS BEING PUBLIC WITH NO CFM'S
 BEING CALCULATED ON THE VENTILATION SCHEDULE BUT THE
 FAN SCHEDULE
 INDICATES 50 CFM EACH (100 CFM) AS PER THE AIR BALANCE,
 YET THE AIR BALANCE SUBTRACTS THIS FROM THE TOTAL CFM
 REQUIRED

Review Stop P PLUMBING
Rev No 3 Status P Date 2014-11-13 Cont ID  
Sent By tklarge Date 2014-11-13 Time 04:37 Rev Time 0.00
Received By tklarge Date 2014-11-13 Time 04:11 Sent To  
Notes
2014-11-12 15:21:34NEW SHEETS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-10-30 Cont ID  
Sent By tklarge Date 2014-10-30 Time 04:58 Rev Time 0.00
Received By tklarge Date 2014-10-30 Time 04:58 Sent To  
Notes
2014-10-30 05:01:551) THE DRINKING FOUNTAINS ARE LOCATED IN THE EMPLOYEE
 BREAK ROOM AND DO NOT APPEAR TO BE ACCESSIBLE TO THE
 PUBLIC. THE PUBLIC SHALL HAVE ACCESS TO THE REQUIRED
 FACILITIES AT ALL TIMES THAT THE BUILDING IS OCCUPIED.
 THE DRINKING FOUNTAINS SHALL BE RELOCATED AND SHALL BE
 ON AN ACCESSIBLE ROUTE TO COMPLY W/ THE
 FL.ACCESSIBILITY CODE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
2014-10-15 14:28:43NEW SHEETS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-09-12 Cont ID  
Sent By tklarge Date 2014-09-12 Time 14:30 Rev Time 0.00
Received By tklarge Date 2014-09-12 Time 14:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-09-18 Cont ID  
Sent By aaponte Date 2014-09-18 Time 09:39 Rev Time 0.00
Received By aaponte Date 2014-09-18 Time 09:39 Sent To  
Notes
***NONE***